5413 PARKVIEW LN 2023 Plans 2024-06-11
>
Address Records
>
PARKVIEW LN
>
5413
>
Plans
>
5413 PARKVIEW LN 2023 Plans 2024-06-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2024 2:31:14 PM
Creation date
6/11/2024 12:00:11 PM
Metadata
Fields
Template:
Address Document
Street Name
PARKVIEW LN
Street Number
5413
Permit
B2309-078
Year
2023
Notes
REMOVE EXISTING DECK AND INSTALL NEW DECK
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M . Buildin Permit.com <br /> y ga service of eCityGov.net Construction Tip Sheet 05 <br /> Deck Construction Notes <br /> • Design loading for decks is based on 60 pounds per square feet (PSF) live load, 10 PSF dead <br /> load, and 1500 PSF soil-bearing capacity. <br /> • The illustrations and information in this tip Sheet may be used for decks whether or not they <br /> require a permit. See Tip Sheet 0 for when a permit is required. <br /> • All wood must be pressure-treated or naturally resistant to decay. Treat cuts, holes, and <br /> notches with end-cut solution. <br /> • Fasteners, hangers, nails, etc., must be stainless steel, hot-dipped galvanized, or as specifically <br /> required for the specified wood preservative used. The coating weights for zinc-coated <br /> fasteners to be in accordance with ASTM A 153. Provide documentation in the field showing <br /> the required fastener protection for the wood chosen for your deck. <br /> • You may modify any components of this Tip Sheet using accepted engineering practices. Any <br /> modifications must be reviewed prior to permit issuance. All attachments must be per <br /> manufacturer's installation instructions. <br /> • Visit MyBuildingPermit.com for additional Tip Sheets for stairs, handrails, and notching and <br /> boring. <br /> 36"minimum high guard <br /> with Intermediate rails Attachment of <br /> spaced so that a sphere pre-manufactured guardail <br /> Existing building 4"In diameter cannot shall bes perdmanufacturennernts <br /> pass through(See Tip Special blocking details may be <br /> Flashing Sheet 3)."-- <br /> Refe required by the reviewer. <br /> See detail 1 on page <br /> 6 tac menr 3 for tablet on page See page 8 foroguardrail <br /> attachment options 3 for Joist Sizes i- --� post connection <br /> Decking and Spans <br /> ( ,fir 1 <br /> Secure balusters with(1)#8d <br /> ( wood screw top&bottom <br /> / Y4"spadng \ / Refer to Table on page 3 for <br /> recommended Beam Size and Spans <br /> Note: for drainage <br /> Contractor to field <br /> verify adequacy of Knee braces are required if <br /> solid lumber for ledger distance from grade to top of <br /> connection. exit or egress poost exceeds 48". See detail <br /> 7—thIfane existing building <br /> 2— p page <br /> passes under the For post size and maximum <br /> ropnosexiedsting deck,or <br /> path if thereunder allowable height,see page 4 <br /> Is a <br /> the proposed deck,6'- " <br /> minimum clearance must <br /> be maintained. Please <br /> Indicate openings In Manufactured post base cast in <br /> existing wall In elevation footing <br /> view. <br /> Rooting Sefer to Table on page 4 for <br /> F <br /> 3p0e0c psoin c oreqncureteed no special <br /> Finished grade <br /> 1"dear—. 4 , I <br /> Minimum ((2)#4 ea.wayy,3"clear <br /> depth of �� fo bottom of footing. <br /> footing 12" Footing to bear on <br /> i undisturbed earth. <br /> January 14,2022 MyBuiidingPermit.com I Basic Deck <br /> / 4 <br /> .N ,�eCityGovnet <br /> 20Q5+;eCItyClis lance <br />
The URL can be used to link to this page
Your browser does not support the video tag.