My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5413 PARKVIEW LN 2023 Plans 2024-06-11
>
Address Records
>
PARKVIEW LN
>
5413
>
Plans
>
5413 PARKVIEW LN 2023 Plans 2024-06-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2024 2:31:14 PM
Creation date
6/11/2024 12:00:11 PM
Metadata
Fields
Template:
Address Document
Street Name
PARKVIEW LN
Street Number
5413
Permit
B2309-078
Year
2023
Notes
REMOVE EXISTING DECK AND INSTALL NEW DECK
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M Buildin Permit.com <br /> Y a service of eCityGov.net Construction Tip Sheet 05 <br /> When using the tables below, interpolation is allowed, extrapolation is not allowed. <br /> Sizing of Structural Elements <br /> Maximum Deck Joist Span a,c <br /> Joist Spacing b Joist Back Span <br /> Joist (inches) <br /> Size 12 16 24 4 6 8 10 12 14 16 18 <br /> Allowable Joist Span Maximum Cantilever (feet-inches Adjacent Joist Span (feet) <br /> 2x6 7-11 7-1 5-9 1-0 1-6 NP NP NP NP NP NP <br /> 2x8 10-5 9-5 7-8 1-0 1-6 2-0 2-1 NP NP NP NP <br /> 2x10 13-3 11-6 9-5 1-0 1-6 2-0 2-6 2-8 NP NP NP <br /> 2x12 15-5 13-4 10-11 1-0 1-6 2-0 2-6 3-0 3-3 NP NP <br /> a. Includes Incising Factor. <br /> b. When using composite decking, refer to manufacturer's installation instructions for <br /> maximum spacing of joists. <br /> c. Spans based on Doug Fir-Larch, Hem Fir and Spruce-Pine-Fir, No. 2 grade, wet service <br /> factor. <br /> Minimum Beam Size <br /> Deck Joist Span (feet) <br /> 6 8 10 12 I 14 16 18 <br /> Beam Maximum Beam Span a,b,d(feet-inches) <br /> Size c,d,e <br /> 4x6 5-2 4-6 4-0 3-5 3-1 2-10 2-7 <br /> 4x8 6-11 6-0 5-3 4-7 4-1 3-8 3-5 <br /> 4x10 8-5 7-4 6-6 5-10 5-2 4-9 4-5 <br /> 4x12 9-10 8-6 7-7 6-11 6-4 5-9 5-4 <br /> 6x6 6-6 5-7 5-0 4-7 4-2 3-9 3-5 <br /> 6x8 8-8 7-6 6-8 6-1 5-6 5-0 4-7 <br /> 6x10 10-7 9-2 8-2 7-6 6-11 6-4 5-10 <br /> 6x12 12-4 10-8 9-7 8-9 8-1 7-7 7-1 <br /> a. Spans based on Doug Fir-Larch, Hem Fir and Spruce-Pine-Fir, No. 2 grade, wet service <br /> factor. <br /> b. If 2x built up beams to make 4x or 6x beams, they shall be fastened with two rows of 10d <br /> (3-inch x 0.128-inch) nails minimum at 16 inches on center along each edge (507.5) <br /> c. Beam depth shall be equal to or greater than the depth of intersecting joist for a flush <br /> beam connection. <br /> d. Beam cantilevers are limited to the adjacent beam's span divided by 4. <br /> e. Includes incising factor. <br /> January 14,2022 MyBuildingPermit.com I Basic Deck <br /> y <br /> 1'4eCityGovnet <br /> 2005 ,sCityGo Hance <br />
The URL can be used to link to this page
Your browser does not support the video tag.