My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
215 SHUKSAN WAY 2024-06-24
>
Address Records
>
SHUKSAN WAY
>
215
>
215 SHUKSAN WAY 2024-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2024 10:48:16 AM
Creation date
6/12/2024 6:49:52 AM
Metadata
Fields
Template:
Address Document
Street Name
SHUKSAN WAY
Street Number
215
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 1:Agent Fluid DESIGN CONCENTRATION NOTES <br /> Physical Properties Table 3: NFPA Minimum Design Concentrations for <br /> Chemical Formula CF3CF2C(0)CF(CF3)2 Fluoro-KTM Fire Suppression Clean Agent <br /> NFPA Reference FK-5-1-12 Class of Fire Minimum Design <br /> Dodecafluoro-2-methylpentan-3-one Concentration <br /> Molecular Weight 316.04 Class A 4.50 <br /> Freezing Point -162.4°F (-108°C) Class B (n-Heptane ) 5.85" <br /> Boiling Point at 1 Atm. 120.6°F(49.2°C) Class B(Ethyl alcohol) 7.02* <br /> Critical Temperature 335.6°F(168.7°C) Class C with Voltage<480 V 4.52 <br /> Critical Density 39.91 Ib./ft.3(639.1 kg/m3) For voltages>_480 volts <br /> Critical Pressure 270.44 PS IA(1865 kPa) that remain powered <br /> during and after <br /> Critical Volume 0.0251 ft.3/lbm(494.5 cc/mole) Class C with Voltage>_480 V discharge,the MDC shall <br /> Ozone Depletion Potential 0 be determined by testing, <br /> as necessary, and a <br /> Global Warming Potential 1 hazard analysis. <br /> For additional Class B values, contact Kidde Fire Systems <br /> Table 2:Agent Fluid Technical Support. <br /> Toxicity Properties <br /> NOAEL FM GLOBAL CLASS C CONCENTRATION VALUES <br /> (No Observable Adverse Effect Level) 10.0% Per the FM Global Property Loss Prevention Data Sheet 4-9, <br /> Interim Revision July 2021, the Class C Fires Minimum Design <br /> LOAEL >10.0% Concentrations for Fluoro-K Fire Suppression Clean Agent are <br /> (Lowest Observable Adverse Effect Level) as follows: <br /> Table 4: FM Global Class C Fires Minimum Design <br /> COMPATIBILITY Concentrations for Fluoro-K Fire Suppression Clean Agent <br /> System Industrial Marine Minimum <br /> Approval Approval Class of Fire Design <br /> ECS-50OTM with Fluoro-KTm Fire Concentration <br /> ress <br /> Su ion Clean Agent UL, ULC, FM UL <br /> pp eang Class C with Voltage<_480 V 4.52 <br /> ADSTM with Fluoro-KTm Fire UL, ULC, FM UL Class C with Voltage>480 V 10 <br /> Suppression Clean Agent <br /> ECSTm 360 with Fluoro-KTm Fire UL, ULC, FM UL Note: The Minimum Design Concentration for Class C fires <br /> Suppression Clean Agent* with voltages greater than 480 volts meets or exceeds <br /> 'This system is no longer offered for sale.Agent is for refill purposes only. the EPAAccepted LOAEL and NOAEL for the agent. <br /> Using this high of an MDC requires use of the follow- <br /> AGENT APPROVALS ing: <br /> Agent Industrial Marine Pneumatic Time Delays <br /> Approval Approval Pneumatic Sirens <br /> • Signs <br /> Kidde Fire Systems Fluoro-KTm Fire UL, ULC, FM UL Lockout Valves <br /> Suppression Clean Agent <br /> EXPORT INFORMATION(USA) <br /> Jurisdiction:EAR <br /> Classification:EAR99 <br /> This document contains technical data subject to the EAR. <br /> All trademarks are the property of their respective owners. <br /> This literature is provided for informational purposes only.KIDDE-FENWAL,INC.believes this data to be accurate,but it is published and presented without any guarantee <br /> or warranty whatsoever.KIDDE-FENWAL,INC.assumes no responsibility for the product's suitability for a particular application.The fire suppression system design, <br /> installation,maintenance,service and troubleshooting must be performed by trained,authorized Kidde Fire Systems distributors for the product to work correctly. <br /> If you need more information on this product,or if you have a particular problem or question,contact: <br /> KIDDE-FENWAL,INC.,Ashland,MA 01721 USA,Telephone:(508)881-2000. <br /> 2 Kidde Fire Systems <br /> Kidde Ashland, <br /> Main Street <br /> or land,MA 01721 <br /> Fire Systems K-45-0900 Rev AA Ph:508.881.2000 <br /> Fax:508.881.8920 <br /> ©2023 Carrier kiddefiresystems.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.