Laserfiche WebLink
Bulk Asbestos Fibers Analysis NVL <br /> By Polarized Light Microscopy <br /> Client: Terracon- Mountlake Terrace Batch #: 2309392.00 <br /> Address: 21905 64th Ave. W#100 Client Project#: 81227459 <br /> Mountlake Terrace, WA 98043 Date Received: 6/14/2023 <br /> Samples Received: 12 <br /> Attention: Mr. Daniel Sheppard Samples Analyzed: 12 <br /> Project Location: POE Equator Shed Method: EPA/600/R-93/116 <br /> Cellulose <11% <br /> Lab ID: 23057213 Client Sample#: 3-03 <br /> Location: POE Equator Shed <br /> Layer 1 of 1 Description: White rubbery material with debris <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Binder/Filler, Fine particles, Organic debris Polyethylene fibers 6% None Detected ND <br /> Lab ID: 23057214 Client Sample#: 4-01 <br /> Location: POE Equator Shed <br /> Layer 1 of 1 Description: Gray brittle material with debris <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Binder/Filler, Fine grains, Fine particles Cellulose <1% None Detected ND <br /> Mineral grains, Organic debris <br /> Lab ID: 23057215 Client Sample#: 4-02 <br /> Location: POE Equator Shed <br /> Layer 1 of 1 Description: Gray brittle material with debris <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Binder/Filler, Fine grains, Fine particles Spider silk <1% None Detected ND <br /> Mineral grains, Organic debris <br /> Lab ID: 23057216 Client Sample#: 4-03 <br /> Location: POE Equator Shed <br /> Layer 1 of 1 Description: Gray brittle material with debris <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Binder/Filler, Fine grains, Fine particles Cellulose <1% None Detected ND <br /> Mineral grains, Organic debris <br /> Sampled by: ClientAV <br /> p�Q�L <br /> Analyzed by: Hilary Crumley Date:06/19/2023 <br /> Reviewed by: Kunga Woser Date:06/19/2023 Kunga Woser, Senior Laboratory Analyst <br /> Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA <br /> 600/R-93/116 and EPA 40 CFR Appendix E to Subpart E of Part 763 with the following measurement uncertainties for the reported %Asbestos(1%=0-3%, <br /> 5%=1-9%, 10%=5-15%,20%=10-30%, 50%=40-60%).This report relates only to the items tested. If sample was not collected by NVL personnel,then the <br /> accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full,without written <br /> approval of NVL Laboratories,Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government <br /> ASB-02 <br /> page 5 of 7 <br />