- .11 <br /> I <br /> Plan Check Number: B2208-1 <br /> 14.This comment has not been addressed. Energy credits for the new conditioned space in the <br /> basement should be specified per WSEC-18 Section C406.1. The performance requirements <br /> should be specified in the drawings. <br /> a. See notations added to drawing A2.3 for required energy credits. <br /> Structural <br /> 1. The Framing Plan on sheet S2.0 includes 4x10 beams. Calculations substantiating the design <br /> are not included in the calculation package and should be submitted for review per IBC Section <br /> 1604.1. Note that calculations and drawings indicate a 50 psf floor live load for"residential" <br /> and "office" loading, respectively. The minimum uniform area load for the A-2 space should be <br /> 100 psf per IBC Table 1607.1; the load is not reducible per Footnote (m). <br /> a. See Structural response letter <br /> 3. The following comments should be addressed for the design of the guards around the new <br /> stairway opening: <br /> a. The construction of the guards on Sheet A4.1 is not clear. The sections and details are not <br /> consistent. If a wall is intended, revised details are required. <br /> a. There is to be a Half wall at the stairs on the main floor and the guard rail <br /> at the stairs leading into the lower floor. Notations have been revised to clarify. <br /> See A2.2 &A4.1 <br /> b. Calculations substantiating the guard connection should be submitted for review. See IBC <br /> Section 1607.8.1. <br /> a. See Structural response letter <br /> c. The guards should specify openings that do not pass a 4-inch sphere per IBC Section <br /> 1015.4. Openings specified as"4-inches maximum"do not comply. <br /> a. The Detail Has been updated. See A4.1 <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> 2 2MATT SCHREIFELS <br /> Project Manager <br /> P 1425-252-2153 E I matts@2812architecture.com <br /> W I www.2812architecture.com A 12812 Colby Ave, Everett,Wa 98201 <br /> Page 4 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.