My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
215 SHUKSAN WAY 2023 Plans 2024-07-08
>
Address Records
>
SHUKSAN WAY
>
215
>
Plans
>
215 SHUKSAN WAY 2023 Plans 2024-07-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2024 1:11:09 PM
Creation date
6/28/2024 1:43:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SHUKSAN WAY
Street Number
215
Permit
B2309-037
Year
2023
Notes
INSTALL 77 BAYS OF PALLET RACKING IN WAREHOUSE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• a <br /> Seattle Genetics 8/4/2023 " <br /> ENGINEERING <br /> E Everett,WA 98203 RVC <br /> N GINE N EERIN G <br /> Anchor Analysis Cont.: <br /> Check For Concrete Breakout-Uplift <br /> k«= 17 Coeff. For Concrete Breakout Strength(ACI Sec. 17.4.2.2) <br /> Aa= 1 Modification Factor for Lightweight Concrete <br /> Nb= 5456 lbs. Concrete Breakout Strength for a Single Anchor(ACI Eq. 17.4.2.2a) <br /> ANCo= 95.1 in.2 Projected Concrete Failure Area of a Single Anchor(ACI Eq. 17.4.2.1c) <br /> ANC= 248.1 in.2 Projected Concrete Failure Area of an Anchor Group(ACI Sec. 17.4.2) <br /> Ncbg= 14236 lbs. Nominal Concrete Breakout Strength of Bolt Group(ACI Eq. 17.4.2.1b) <br /> = 0.65 Strength Reduction Factor <br /> Old),= 6940 lbs. Factored Breakout Capacity of Bolt Group <br /> Nua,g= 3239 lbs. Ultimate Uplift per Anchor Group <br /> Nua/ kN = 0.47 OK Utilization Such That Ncbg>_ Nua,g <br /> Cat Si 1.5hef <br /> lommemr AN° <br /> Check For Anchor Strength-Shear 1.5h <br /> � of <br /> N = 4 Number of Anchors in Group <br /> Vsa= 6875 lbs. Nominal Shear Strength per Anchc 82 . <br /> = 0.65 Strength Reduction Factor Paz <br /> 4Vsa= 4469 lbs. Factored Shear Strength per Anchi <br /> Vua= 752 lbs. Ultimate Shear per Anchor <br /> Vua/kV = 0.17 OK Utilization Such That ckVsa>Vua <br /> Check For Concrete Pryout Strength-Shear <br /> N = 4 Number of Anchors in Group <br /> Ncpg= 14236 lbs. Nominal Concrete Breakout Strength of Bolt Group (ACI Eq. 17.4.2.1b) <br /> kip= 2 Coeff. For Pryout Strength (ACI Sec. 17.5.3.1) <br /> Vcpg= 28472 lbs. Nominal Pryout Strength for Anchor Group(ACI Eq. 17.5.3.1b) <br /> = 0.70 Strength Reduction Factor <br /> itV„g= 19930 lbs. Factored Pryout Strength of Bolt Group <br /> Vua g= 3008 lbs. Ultimate Shear per Anchor Group <br /> Vua/4V„= 0.15 OK Utilization Such That ckVcbg>Vua,g <br /> Interaction of Tension and Shear Loads <br /> Nua = 0.47 Max. Utilization for Tension (Uplift) <br /> Vua/cl:V„= 0.17 Max. Utilization for Tension (Shear) <br /> Utilization= 0.33 OK Max. Utilization for Combined Tension and Shear <br /> s/3 V s/3 <br /> H + ua < 1.0 (ACI Section R17.6) <br /> ) cPUn <br /> 49/49 <br />
The URL can be used to link to this page
Your browser does not support the video tag.