6/14/23,3 07 PM Chapter 7: Fire and Smoke Protection Features,2021 Washington State Building Code I UpCodes <br /> wire tied onto outer loop of clips,metal lath wire-tied to pencil rods at 6"intervals, 1"perlite gypsum <br /> plaster,each side. <br /> 21/2"x 0.044"(No. 18 carbon sheet steel gage)steel studs spaced 16"on center.Wood fibered gypsum <br /> 11-1.4 plaster mixed 1:1 by weight gypsum to sand aggregate applied on 3/4-pound metal lath wire tied to studs, — — 41/4d each side.3/4'plaster applied over each face,including finish coat. <br /> 2"x 4"wood studs 16"on center with 5/8"gypsum plaster on metal lath.Lath attached by 4d common <br /> 12-1.11,m nails bent over or No.14 gage by 11/4"by 3/4"crown width staples spaced 6"on center.Plaster mixed — — — 51/8 <br /> 1:11/2 for scratch coat and 1:3 for brown coat,by weight,gypsum to sand aggregate. <br /> 12 1.2� 2"x 4"wood studs 16"on center with metal lath and 7/8"neat wood-fibered gypsum plaster each side. — — 51/ d <br /> 12.Wood studs— Lath attached by 6d common nails,7"on center.Nails driven 11/4'and bent over. 2 <br /> interior partition with 2"x 4"wood studs 16"on center with 3/8"perforated or plain gypsum lath and 1/2"gypsum plaster each <br /> plaster each side 12-1.31 side.Lath nailed with 11/ "byNo. 13 gage by19/ headplasterboard blued nails,4"on center.Plaster — — — 51/ <br /> a g g 6a" a <br /> mixed 1:2 by weight,gypsum to sand aggregate. <br /> 2"x 4"wood studs 16"on center with 3/8"Type X gypsum lath and 1/2"gypsum plaster each side. Lath <br /> 12-1.41 nailed with 11/8"by No. 13 gage by 19/64"head plasterboard blued nails,5"on center.Plaster mixed 1:2 by — — — 51/4 <br /> weight,gypsum to sand aggregate. <br /> 0.018"(No.25 carbon sheet steel gage)channel-shaped studs 24"on center with one full-length layer of <br /> 5/8"Type X gypsum wallboards applied vertically attached with 1"-long No.6 dry wall screws to each stud. <br /> Screws are 8"on center around the perimeter and 12"on center on the intermediate stud.Where applied d <br /> 13 1.1 horizontally,the Type X gypsum wallboard shall be attached to 35/8"studs and the horizontal joints shall 2 /8 <br /> be staggered with those on the opposite side.Screws for the horizontal application shall be 8"on center <br /> at vertical edges and 12"on center at intermediate studs. <br /> 13.Noncombustible 0.018"(No.25 carbon sheet steel gage)channel-shaped studs 25"on center with two full-length layers of <br /> studs—interior <br /> 1/2'Type X gypsum wallboards applied vertically each side.First layer attached with 1"-long,No.6 drywall <br /> partition with gypsum <br /> wallboard each side 13 1.2 screws,8"on center around the perimeter and 12"on center on the intermediate stud.Second layer — — 35/ed <br /> applied with vertical joints offset one stud space from first layer using 1 /8"long,No.6 drywall screws <br /> spaced 9"on center along vertical joints, 12"on center at intermediate studs and 24"on center along top <br /> and bottom runners. <br /> 0.055"(No. 16 carbon sheet steel gage)approved nailable metal studse 24"on center with full-length 5/8" <br /> 13-1.3 Type X gypsum wallboards applied vertically and nailed 7"on center with 6d cement-coated common — — — 47/8 <br /> nails.Approved metal fastener grips used with nails at vertical butt joints along studs. <br /> 14.Wood studs— 2"x 4"wood studs 16"on center with two layers of 3/8"regular gypsum wallboards each side,4d cooler" <br /> interior partition with h m or wallboard"nails at 8"on center first layer,5d cooler"or wallboard"nails at 8"on center second layer <br /> gypsum wallboard 14 1.1 with laminating compound between layers,joints staggered.First layer applied full length vertically, 5 <br /> each side second layer applied horizontally or vertically. <br /> https://up.codes/viewer-export/washington/wa-building-code-2021/chapter/7/fire-and-smoke-protection-features#721.1 9/28 <br />
The URL can be used to link to this page
Your browser does not support the video tag.