Laserfiche WebLink
6/14/23,3:07 PM Chapter 7: Fire and Smoke Protection Features,2021 Washington State Building Code I UpCodes <br /> 2"x 4"wood studs 16"on center with two layers 1/2"regular gypsum wallboards applied vertically or <br /> 14-1.21,m horizontally each sidek,joints staggered.Nail base layer with 5d cooler"or wallboard"nails at 8"on — — — 51/2 <br /> center face layer with 8d cooler"or wallboard"nails at 8"on center. <br /> 2"x 4"wood studs 24"on center with 5/8"Type X gypsum wallboards applied vertically or horizontally <br /> 14-1.31 m nailed with 6d cooler"or wallboard"nails at 7"on center with end joints on nailing members.Stagger — — — 43/4 <br /> joints each side. <br /> 2"x 4"fire-retardant-treated wood studs spaced 24"on center with one layer of 5/8"Type X gypsum <br /> 14-1.41 wallboarde applied with face paper grain(long dimension)parallel to studs.Wallboard attached with 6d — — — 43/4d <br /> cooler"or wallboard"nails at 7"on center. <br /> 2"x 4"wood studs 16"on center with two layers 5/8"Type X gypsum wallboarde each side.Base layers <br /> applied vertically and nailed with 6d cooler"or wallboard"nails at 9"on center. Face layer applied <br /> 14-1.51,m vertically or horizontally and nailed with 8d cooler"or wallboard"nails at 7"on center. For nail-adhesive — — 6 — <br /> application, base layers are nailed 6"on center. Face layers applied with coating of approved wallboard <br /> adhesive and nailed 12"on center. <br /> 2"x 3"fire-retardant-treated wood studs spaced 24"on center with one layer of 5/8"Type X gypsum <br /> 14-1.61 wallboarde applied with face paper grain(long dimension)at right angles to studs.Wallboard attached — — — 35/8d <br /> with 6d cement-coated box nails spaced 7"on center. <br /> 15.Exterior or Exterior surface with 3/4'drop siding over 1/2"gypsum sheathing on 2"x 4"wood studs at 16"on center, <br /> interior walls i m interior surface treatment as required for 1-hour-rated exterior or interior 2"x 4"wood stud partitions. <br /> 15 1.1 Gypsum sheathingnailed with 13/ " No.11 gage 7/ headgalvanized nails at 8"on center.Siding <br /> — — Varies <br /> YP a by g g by 16" g <br /> nailed with 7d galvanized smooth box nails. <br /> 2"x 4"wood studs 16"on center with metal lath and 3/4"cement plaster on each side.Lath attached with <br /> 15-1.21'm 6d common nails 7"on center driven to 1"minimum penetration and bent over.Plaster mix 1:4 for — — — 53/8 <br /> scratch coat and 1:5 for brown coat,by volume,cement to sand. <br /> 2"x 4"wood studs 16"on center with 7/8"cement plaster(measured from the face of studs)on the <br /> 15-1.31'm exterior surface with interior surface treatment as required for interior wood stud partitions in this table. — — — Varies <br /> Plaster mix 1:4 for scratch coat and 1:5 for brown coat,by volume,cement to sand. <br /> 35/8"No. 16 gage noncombustible studs 16"on center with 7/8"cement plaster(measured from the face <br /> of the studs)on the exterior surface with interior surface treatment as required for interior,nonbearing, <br /> 15 1.4 Variesd <br /> noncombustible stud partitions in this table. Plaster mix 1:4 for scratch coat and 1:5 for brown coat, by — — <br /> volume,cement to sand. <br /> 15-1.5m 21/4'x 33/4"clay face brick with cored holes over 1/2"gypsum sheathing on exterior surface of 2"x 4" — — 10 — <br /> wood studs at 16"on center and two layers 5/8'Type X gypsum wallboards on interior surface.Sheathing <br /> placed horizontally or vertically with vertical joints over studs nailed 6"on center with 13/4"x No. 11 gage <br /> by'/18"head galvanized nails. Inner layer of wallboard placed horizontally or vertically and nailed 8"on <br /> center with 6d cooler"or wallboard"nails.Outer layer of wallboard placed horizontally or vertically and <br /> nailed 8"on center with 8d cooler"or wallboard"nails.Joints staggered with vertical joints over studs. <br /> https://up.codes/viewer-export/washington/wa-building-code-2021/chapter/7/fire-and-smoke-protection-features#721.1 / 10/28 <br />