6/14/23,,3:07 PM Chapter 7 Fire and Smoke Protection Features,2021 Washington State Building Code I UpCodes <br /> Outer layer joints taped and finished with compound.Nail heads covered with joint compound.0.035 <br /> inch(No.20 galvanized sheet gage)corrugated galvanized steel wall ties 3/4"by 65/8"attached to each <br /> stud with two 8d coolers or wallboards nails every sixth course of bricks. <br /> 2"x 6"fire-retardant-treated wood studs 16"on center. Interior face has two layers of 5/8"Type X gypsum <br /> with the base layer placed vertically and attached with 6d box nails 12"on center.The face layer is placed <br /> horizontally and attached with 8d box nails 8"on center at joints and 12"on center elsewhere.The <br /> exterior face has a base layer of 5/8"Type X gypsum sheathing placed vertically with 6d box nails 8"on <br /> center at joints and 12"on center elsewhere.An approved building paper is next applied,followed by self- <br /> 15-1.61,m furred exterior lath attached with 21/2",No. 12 gage galvanized roofing nails with a 3/8"diameter head — — 81/4 and spaced 6"on center along each stud.Cement plaster consisting of a 1/2"brown coat is then applied. <br /> The scratch coat is mixed in the proportion of 1:3 by weight,cement to sand with 10 pounds of hydrated <br /> lime and 3 pounds of approved additives or admixtures per sack of cement.The brown coat is mixed in <br /> the proportion of 1:4 by weight,cement to sand with the same amounts of hydrated lime and approved <br /> additives or admixtures used in the scratch coat. <br /> 2"x 6"wood studs 16"on center.The exterior face has a layer of 5/8"Type X gypsum sheathing placed <br /> vertically with 6d box nails 8"on center at joints and 12"on center elsewhere.An approved building <br /> paper is next applied,followed by 1"by No.18 gage self-furred exterior lath attached with 8d by 21/2"- <br /> long galvanized roofing nails spaced 6"on center along each stud.Cement plaster consisting of a 1/2" <br /> scratch coat,a bonding agent and a 1/2"brown coat and a finish coat is then applied.The scratch coat is <br /> mixed in the proportion of 1:3 by weight,cement to sand with 10 pounds of hydrated lime and 3 pounds <br /> 15-1.71,m of approved additives or admixtures per sack of cement.The brown coat is mixed in the proportion of 1:4 — — 83/8 by weight,cement to sand with the same amounts of hydrated lime and approved additives or <br /> admixtures used in the scratch coat.The interior is covered with 3/8"gypsum lath with 1"hexagonal mesh <br /> of 0.035 inch(No.20 B.W.gage)woven wire lath furred out 5/16"and 1"perlite or vermiculite gypsum <br /> plaster.Lath nailed with 11/8'by No.13 gage by 19/64"head plasterboard glued nails spaced 5"on center. <br /> Mesh attached by 13/4"by No.12 gage by 3/8"head nails with 3/8"furrings,spaced 8"on center.The <br /> plaster mix shall not exceed 100 pounds of gypsum to 21/2 cubic feet of aggregate. <br /> 2"x 6"wood studs 16"on center.The exterior face has a layer of 5/8"Type X gypsum sheathing placed <br /> vertically with 6d box nails 8"on center at joints and 12"on center elsewhere.An approved building <br /> paper is next applied,followed by 11/2"by No. 17 gage self-furred exterior lath attached with 8d by 21/2"- <br /> long galvanized roofing nails spaced 6"on center along each stud.Cement plaster consisting of a 1/2" <br /> scratch coat and a 1/2"brown coat is then applied.The plaster may be placed by machine.The scratch <br /> 15-1.81,m coat is mixed in the proportion of 1:4 by weight,plastic cement to sand.The brown coat is mixed in the — — 83/8 — <br /> proportion of 1:5 by weight,plastic cement to sand.The interior is covered with 3/8"gypsum lath with 1" <br /> hexagonal mesh of No.20-gage woven wire lath furred out 5/16"and 1"perlite or vermiculite gypsum <br /> plaster.Lath nailed with 11/8"by No. 13 gage by 19/64'head plasterboard glued nails spaced 5"on center. <br /> Mesh attached by 13/4"by No.12 gage by 3/8"head nails with 3/8"furrings,spaced 8"on center.The <br /> plaster mix shallnot exceed 100 pounds of gypsum to 21/2 cubic feet of aggregate. <br /> 15-1.9 4"No. 18 gage,nonload-bearing metal studs, 16"on center,with 1"Portland cement lime plaster — — 61/2d — <br /> (measured from the back side of the 3/4-pound expanded metal lath)on the exterior surface.Interior <br /> surface to be covered with 1"of gypsum plaster on 3/4-pound expanded metal lath proportioned by <br /> https.//up.codes/viewer-export/washington/wa-building-code-2021/chapter/7/fire-and-smoke-protection-features#721.1 / 11/28 <br />
The URL can be used to link to this page
Your browser does not support the video tag.