My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3810 RIVERFRONT BLVD BLDG B 2025-07-07
>
Address Records
>
RIVERFRONT BLVD
>
3810
>
BLDG B
>
3810 RIVERFRONT BLVD BLDG B 2025-07-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2025 10:24:40 AM
Creation date
7/19/2024 1:10:31 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3810
Tenant Name
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
543
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. Wall type 64 is called out on the floor plans however is not provided on Sheet AB501. <br />9. The MPOE and IDF rooms are noted as having two-hour enclosure walls on Sheet GB034: <br />a. The walls for the MPOE room are called out on Sheet AB101.S as two hours (FYI). <br />b. The IDF rooms above are not specified as two-hour on the floor plans. <br />c. All doors into the MPOE and IDF rooms are shown as 20-minute (only) and not <br />90-minute (as would be expected). <br />i. Will the stacked rooms act as a vertical shaft (please clarify)? <br />Egress <br />1. Even though Doors 118, 146 & 129 are not required egress doors, per Section 1010.1 <br />they can be used as egress and should comply with the requirements of egress doors <br />from the space(s) served. The doors should therefore swing in the direction of travel and <br />be provided with panic hardware. Sections 1010.1.2.1 & 1010.1.10 <br />2. Door 136 should be provided with panic hardware. Section 1010.1.10 <br />3. The stairs in the Type I portion of the building should be constructed from non- <br />combustible materials per Section 1011.7. It has been our standard accepted modification <br />in these building types (Section 510.2) however to permit the stair enclosures in the Type <br />I stories to be upgraded to minimum 3-hour shafts with 3-hour doors. In this building, as <br />the walls are already 3 hours, only the doors need be upgraded if this option is pursued. <br />Section 104.10 <br />4. The locations, use -instructions and signage requirements for the two-way communication <br />system at the elevator landings should be shown on the plans (Elevator Note 7/AB520). <br />Section 1009.8 <br />5. A sign stating Exit in raised characters and braille and complying with ICC A117.1 should <br />be shown adjacent to the exterior exit doorways. Section 1013.4 <br />6. The exterior guards at the unit balconies should be detailed on the plans. Section 1015 <br />7. The interior guard shown in Building Section 1/AB302 appears to be less than 42' in <br />height. Section 1015.3 <br />The construction of the stairs in the sales area should be shown on the plans. As these <br />are the required egress access stairways, I would not consider them to be required to be <br />of noncombustible construction. <br />Accessibility (ANSI A117.1) <br />1. The design basis behind the number, location and distribution of accessible parking spaces <br />throughout the site(s) should be provided for this group of buildings/parking areas. <br />Section 1106.2 <br />(�} 3200 Cedar Street O 425.257.8810 O tlee@everettwa.gov <br />V Everett, WA 99201 425.257.8857 fax everettwa.gov <br />