My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1711 125TH PL SE 2024-11-15
>
Address Records
>
125TH PL SE
>
1711
>
1711 125TH PL SE 2024-11-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2024 9:13:19 AM
Creation date
7/19/2024 2:50:17 PM
Metadata
Fields
Template:
Address Document
Street Name
125TH PL SE
Street Number
1711
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. <br />PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN — USING THEIR PROSPECTIVE <br />RESIDENT BEDROOM DESIGNATIONS OF A B C D E AND FAND CLASSIFICATION CODE S, NS1 OR NS2. <br />R330.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: <br />Type S — where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area. <br />Type NS1- where 1 means of egress at grade level (has no stairs) or ramp constructed compliant with R330.9 is provided to evacuate <br />residents to public area. <br />Type NS2 — where 2 means of egress at grade level (both have no stairs) or ramps constructed compliant with R330.9 are provided to <br />evacuate residents to public area. <br />SLEEPING ROOM A <br />0Type S Type NS1 OType NS2 <br />YES <br />NO <br />ide Closet door/s are readily openable from the insYes 0 No ON/A I Smoke alarm is installed in the bedroom <br />0 <br />Bedroom door opens easily and quickly from the outside when locked <br />0 <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />1; <br />0 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />0 <br />SLEEPING ROOM B I E3 Type S Type NS1 113 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside IM Yes 113 No ON/A I Smoke alarm is installed in the bedroom <br />0 <br />Bedroom door opens easily and quickly from the outside when locked <br />0 <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />0 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />0 <br />SLEEPING ROOM C 113 Type S JEJType NS1 10 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside IM Yes JE3 No I ON/A I Smoke alarm is installed in the bedroom <br />0 <br />Bedroom door opens easily and quickly from the outside when locked <br />1 <br />0 <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />® <br />0 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />0 <br />SLEEPING ROOM D 10 Type S 113 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside In Yes 113 No ON/A I Smoke alarm is installed in the bedroom <br />0 <br />Bedroom door opens easily and quickly from the outside when locked <br />0 <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />Q <br />0 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />51 <br />0 <br />SLEEPING ROOM E 10 Type S JqType NS1 10 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside In Yes 0 No ON/A I Smoke alarm is installed in the bedroom <br />El <br />0 <br />Bedroom door opens easily and quickly from the outside when locked <br />E3 <br />0 <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />0 <br />Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />0 <br />SLEEPING ROOM F 10 Type S 0 Type NS1 10 Type NS2 <br />YES <br />NO <br />Closet door/s are readily openable from the inside 0 Yes 0 No ON/A I Smoke alarm is installed in the bedroom <br />0 <br />0 <br />Bedroom door opens easily and quickly from the outside when locked <br />0 <br />0 <br />Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) <br />EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF <br />0 <br />0 <br />SleepingToom window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed <br />0 <br />0 <br />Implementation Date: 2021 February 01 <br />Updated: 2021 February <br />
The URL can be used to link to this page
Your browser does not support the video tag.