Laserfiche WebLink
GENERAL - <br />YES <br />NO <br />Bathroom doors are easily and quickly openable from the outside when locked <br />0 <br />Carbon Monoxide alarms are installed as required in R315 on each level of the home. <br />.O <br />Cj <br />Smoke alarms are installed on all levels of the dwelling, in each resident sleeping room, outside each separate <br />sleeping area in the immediate vicinity of sleeping rooms (R314). <br />0 <br />0 <br />Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all <br />parts of the dwelling upon activation of a single device. <br />P <br />13 <br />Access road and water supply meet local fire jurisdictional requirements. <br />Q <br />R330.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable <br />with one hand and shall not require tight grasping, pinching or twisting of the wrist (lever -type), <br />Cl <br />Pocket doors shall have graspable hardware available when in the closed or open position. <br />0 <br />R311.8 Ramp <br />YES <br />NO <br />Inside Ramp <br />I N/A <br />Q <br />13 <br />R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in <br />0 <br />Q <br />R330.9) <br />R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where <br />ramp changes directions. <br />13 <br />0 <br />R330.9.1 Handrails required on both sides of ramp. <br />13 <br />13 <br />Outside Ramp I N/A 13 1 <br />YES <br />NO <br />R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in <br />E3 <br />R330.9) <br />R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where <br />a <br />ramp changes directions. <br />R330.9.1 Handrails required on both sides of ramp. <br />[] <br />R312.1.1 Guards shall be located along open -sided walking surfaces, that are located more than 30 inches measured <br />Q <br />vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. <br />Guards below are depicted vertically as an example only. <br />Guard <br />36" mit <br />t— <br />minimum <br />is an 8.3% slope all along surface of the ramp. <br />minimum <br />Implementation Date: 2021 February 01 <br />Updated: 2021 February <br />