STANDARD LABELS <br />OWARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />RATED AC OUTPUT CURRENT 32.75 A <br />NOMINAL OPERATING AC VOLTAGE 240 V <br />7NWARNING <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND <br />PV SOLAR ELECTRIC SYSTEM <br />AWARNINGj <br />POWER SOURCE OUTPUT CONNECTION <br />DO NOT RELOCATE <br />THIS OVERCURRENT <br />DEVICE <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />WARNING <br />MAIN DISTRIBUTION UTILITY DISCONNECT(S) <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM A ROOF MOUNTED SOLAR ARRAY WITH <br />A RAPID SHUTDOWN DISCONNECTING MEANS <br />GROUPED AND LABELED WITHIN LINE OF SITE <br />AND 10 FT OF THIS LOCATION <br />LABELING NOTES <br />LABEL 1 <br />FOR PV SYSTEM DISCONNECTING MEANS WHERE THE <br />LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE <br />OPEN POSITION. <br />[2017 NEC 690.13(B)] <br />[2020 NEC 690.13(B)] <br />LABEL 2 <br />SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT <br />THE DISCONNECTING MEANS AS A POWER SOURCE <br />AND WITH THE RATED AC OUTPUT CURRENT AND THE <br />NOMINAL OPERATING AC VOLTAGE. <br />[2017 NEC 690.541 <br />[2020 NEC 690.541 <br />LABEL 3 <br />IF INTERCONNECTING LOAD SIDE, INSTALL THIS LABEL <br />ANYWHERE THAT IS POWERED BY BOTH THE UTILITY <br />AND THE SOLAR PV SYSTEM, IE. MAIN SERVICE PANEL <br />AND SUBPANELS. <br />12017 NEC 705.12(B)(3)] <br />12020 NEC 705.12(B)(3)] <br />LABEL 4 <br />APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT <br />TO THE BACK -FED BREAKER FROM THE POWER <br />SOURCE. <br />[2017 NEC 705.12(B)(2)(3)(b)] <br />12020 NEC 705.12(B)(3)(2)] <br />WARNING) <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM MAIN DISTRIBUTION <br />UTILITY DISCONNECT LOCATED <br />WARNING <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM A ROOF MOUNTED SOLAR ARRAY. SOLAR <br />ARRAY RAPID SHUTDOWN DISCONNECT IS <br />LOCATED OUTSIDE NEXT TO THE UTILITY METER. <br />OWARNING_,, <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />DO NOT ADD LOADS <br />LABEL 6 <br />BUILDINGS WITH PV SYSTEMS SHALL HAVE A <br />PERMANENT LABEL LOCATED AT EACH SERVICE <br />EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS <br />ARE CONNECTED OR AT AN APPROVED READILY <br />VISIBLE LOCATION AND SHALL INDICATE THE LOCATION <br />OF RAPID SHUTDOWN INITIATION DEVICES. <br />12017 NEC 690.56(C)(1)(a)] UTILITY MAIN <br />[2020NEC 690.56(C)] METER SERVICE PANEL <br />LABEL 7 <br />SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT <br />SWITCH <br />12017 NEC 690.56(C)(3)] <br />12020 NEC 690.56(C)(2)] <br />LABEL 8 <br />PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br />LOCATION OF ALL ELECTRIC POWER SOURCE <br />DISCONNECTING MEANS ON OR IN THE PREMISES <br />SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT <br />LOCATION AND AT THE LOCATION(S) OF THE SYSTEM <br />DISCONNECT(S) FOR ALL ELECTRIC POWER <br />PRODUCTION SOURCES CAPABLE OF BEING <br />INTERCONNECTED. <br />[2017 NEC 705.10] <br />[2020 NEC 705.101 <br />1) LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT <br />REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. <br />2) LABELING REQUIREMENTS BASED ON THE 2017 & 2020 NEC CODE, OSHA STANDARD 19010.145, ANSIZ535. <br />3) MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. <br />4) LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE <br />HANDWRITTEN [NEC 110.211 <br />O O <br />U20 O O <br />O IF BREAKER <br />0 IS USED <br />O$ OR 8 <br />OR PLACARD <br />ADDITIONAL LABELS <br />- <br />BLUE RAVEN <br />LABEL9 <br />PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br />LABEL U20 <br />LOCATION OF ALL ELECTRIC POWER SOURCE <br />PLACARD TO BE LOCATED AT UTILITY METER. <br />DISCONNECTING MEANS ON OR IN THE PREMISES <br />1403 N. Research Way <br />SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT <br />Orem, UT 84097 <br />LOCATION AND AT THE LOCATION(S) OF THE SYSTEM <br />DISCONNECT(S) FOR ALL ELECTRIC POWER <br />8 .4480 <br />PRODUCTION SOURCES CAPABLE OF BEING <br />WWW.BLUERAVENSOLAR.COM <br />RAV <br />CONFIDENTIAL- THE INFORMATION <br />INTERCONNECTED. <br />[2017 NEC 705.10] <br />HEREIN CONTAINED SHALL NOT BE <br />[2020 NEC 705.10] <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />LABEL 10 <br />IN PART TO OTHERS OUTSIDE <br />PERMANENT PLAQUE OR DIRECTORY TO BE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />LOCATED AT MAIN SERVICE EQUIPMENT DENOTING <br />IN CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE EQUIPMENT, <br />THE LOCATION OF THE RAPID SHUTDOWN SYSTEM <br />WITHOUT THE WRITTEN PERMISSION <br />DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br />OF BLUE RAVEN SOLAR LLC. <br />SHUTDOWN DISCONNECTING SWITCH IS NOT <br />GROUPED AND WITHIN LINE OF SITE OF MAIN <br />SERVICE DISCONNECTING MEANS. <br />NA BC E P <br />[2017 NEC 705.10 AND 690.56(C) (1) (a)] <br />[2020 NEC 705.10 AND 690. 56(C)] <br />CERTIFIED <br />PV INSTALLATION <br />LABEL 11 <br />PROFESSIONAL <br />PERMANENT PLAQUE OR DIRECTORY TO BE <br />LOCATED AT AC COMBINER PANEL. <br />Scott Gurney <br />[2017 NEC 110.21(8)] <br />#PV-011719-015866 <br />[2020 NEC 110.21(8)] <br />CONTRACTOR: <br />BRS FIELD OPS <br />800-377-4480 <br />Q c) <br />O Mo L <br />r` Lr) <br />N� 00 °�° o <br />LL a <br />O > o w w <br />SUBPANEL PV ILLN N <br />(IF INTERCONNECTION AC METER PV COMBINER Z N N U) N <br />IS MADE HERE) DISCONNECT (IF APPLICABLE) BOX -a Cn C <br />W > (U <br />w HljZ 0 M N N <br />f Cl)Cl) <br />U 2"t W Q 0 <br />4 g g OR PLACARD p0.� 4 �g7�1� DRAWING BY: <br />SS�ONAl.�O <br />Brendan Fillmore <br />I� <br />2023.11.06 <br />09:30:20-07'00' <br />*ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL <br />REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED <br />MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE <br />DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />PLOT DATE: <br />November 3, 2023 <br />PROJECT NUMBER: <br />870808 <br />SHEET NAME: <br />LABELS <br />REVISION: PAGE NUMBER: <br />0 1 PV7 <br />