Laserfiche WebLink
GILBERTO ROBAYO <br /> 1624 HOYT AVE <br /> B2308-030 <br /> Structural (Reviewer: Cal Bearman) <br /> 1. Per IRC Table 301.5, handrail shall resist 200lbs concentrated live load, please note <br /> accordingly. <br /> 2. Please provide header to stud detail per IRC 602.7.2, including but not limited to header <br /> sizes and stud quantity where new openings are created or existing openings exist without <br /> header information. <br /> 3. Details for the construction of the new basement walls should be included. The details <br /> should specify connections for the top and bottom framing plates to the existing <br /> structure. See IRC Sections R106.1.1 and R301.1. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Sincerely, <br /> Yin Lu, R.A. <br /> Development Technician — Residential Building Reviewer <br /> (425)257-7299 <br /> ylu@everettwa.gov <br /> S:\#Common\Bldg Permit Reviews\2_Residential Reviews\1624 Hoyt Ave- ex ADU remodel\B2308-030- <br /> 1624 Hoyt Ave - 1st Building Review.docx <br /> 3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of 3 <br />