STANDARD LABELS ADDITIONAL LABELS <br /> LABEL 1 LABEL 8 BLUE RAVEN <br /> WARNINGFOR PV SYSTEM DISCONNECTING MEANS WHERE THE WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br /> LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE LOCATION OF ALL ELECTRIC POWER SOURCE <br /> ELECTRIC SHOCK HAZARD OPEN POSITION. MAIN DISTRIBUTION UTILITY DISCONNECT(S) DISCONNECTING MEANS ON OR IN THE PREMISES 1403 N. Research Way <br /> (2017 NEC 690.13(8)] POWER TO THIS BUILDING IS ALSO SUPPLIED SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT Orem, UT 84097 <br /> TERMINALS ON THE LINE AND (2020 NEC 690.13(8)] FROM A ROOF MOUNTED SOLAR ARRAY WITH LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> LOAD SIDES MAY BE ENERGIZED A RAPID SHUTDOWN DISCONNECTING MEANS DISCONNECT(S)FOR ALL ELECTRIC POWER <br /> 800.377.4480 <br /> IN THE OPEN POSITION GROUPED AND LABELED WITHIN LINE OF SITE PRODUCTION SOURCES CAPABLE OF BEING WWW.BLUERAVENSOLAR.COM <br /> AND 10 FT OF THIS LOCATION INTERCONNECTED. <br /> CONFIDENTIAL-THE INFORMATION <br /> (2017 NEC 705.10] HEREIN CONTAINED SHALL NOT BE <br /> (2020 NEC 705.10] USED FOR THE BENEFIT OF ANYONE <br /> LABEL 2 EXCEPT BLUE RAVEN SOLAR NOR <br /> PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR <br /> THE DISCONNECTING MEANS AS A POWER SOURCE LABEL 9 IN PART TO OTHERS OUTSIDE <br /> I AC DISCONNECT I AND WITH THE RATED AC OUTPUT CURRENT AND THE WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE RECIPIENTS ORGANIZATION,EXCEPT <br /> NOMINAL OPERATING AC VOLTAGE. LOCATION OF ALL ELECTRIC POWER SOURCE IN CONNECTION WITH THE SALE AND <br /> (2017 NEC 690.54] USE OF THE RESPECTIVE EQUIPMENT, <br /> RATED AC OUTPUT CURRENT 24.89 A POWER TO THIS BUILDING IS ALSO DISCONNECTING MEANS ON OR IN THE PREMISES WITHOUT THE WRITTEN PERMISSION <br /> (2020 NEC 690.541 SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT OF BLUE RAVEN SOLAR LLC. <br /> NOMINAL OPERATING AC VOLTAGE 240 V SUPPLIED FROM MAIN DISTRIBUTION LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> UTILITY DISCONNECT LOCATED DISCONNECT(S)FOR ALL ELECTRIC POWER <br /> PRODUCTION SOURCES CAPABLE OF BEING �+ <br /> INTERCONNECTED. NAB C E P <br /> LABEL 3 (2017 NEC 705.10] <br /> IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL (2020 NEC 705.10] CERTIFIED] <br /> ANYWHERE THAT IS POWERED BY BOTH THE UTILITY <br /> DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL <br /> AND SUBPANELS. PV INSTALLATION <br /> (2017 NEC 705.12(B)(3)] LABEL EN PROFESSIONAL <br /> SOURCES: UTILITY GRID AND (2020 NEC 705.12(B)(3)] I WARNING PERMANENT PLAQUE DIRECTORY Scott Gurney <br /> PV SOLAR ELECTRIC SYSTEM LOCATED AT MAIN SERVVICE EQUIPMENTT DENOTING Y <br /> 7FRA <br /> R TO THIS BUILDING IS ALSO SUPPLIED THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 <br /> ROOF MOUNTED SOLAR ARRAY.SOLAR DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br /> SHUTDOWN DISCONNECTING SWITCH IS NOT CONTRACTOR: <br /> AY RAPID SHUTDOWN DISCONNECT IS GROUPED AND WITHIN LINE OF SITE OF MAIN <br /> LABEL4 BRS FIELD OPS <br /> WA APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT LOCATED OUTSIDE NEXT TO THE UTILITY METER. SERVICE DISCONNECTING MEANS. <br /> TO THE BACK-FED BREAKER FROM THE POWER (2017 NEC 705.10 AND 690.56(C)(1)(a)] 800-377-4480 <br /> POWER SOURCE OUTPUT CONNECTION SOURCE. (2020 NEC 705.10 AND 690.56(C)] <br /> DO NOT RELOCATE [2017 NEC 705.12(B)(2)(3)(b)] <br /> (2020 NEC 705.12(8)(3)(2)] <br /> THIS OVERCURRENT LABEL 11 U <br /> DEVICE IWARNING PERMANENT PLAQUE OR DIRECTORY TO BE Q U <br /> LOCATED AT AC COMBINER PANEL. <br /> PHOTOVOLTAIC SYSTEM [2017 NEC 110.21(8)] Z <br /> WARNING LABEL 5 COMBINER PANEL 12020 NEC 110.21(8)] co <br /> APPLY TO THE PV COMBINER BOX0 00 co <br /> (2017 NEC 705.12(B)(2)(3)(c)] Q04 <br /> (2020 NEC 705.12(6)(3)(3)] DO NOT ADD LOADS 000CF) <br /> a? <br /> THIS EQUIPMENT FED BY MULTIPLE Lf) ~ <br /> 0 <br /> SOURCES.TOTAL RATING OF ALL W LJ.I <br /> OVERCURRENT DEVICES,EXCLUDING PV O � N N <br /> MAIN SUPPLY OVERCURRENT SUBPANEL Z > C: N <br /> DEVICE,SHALL NOT EXCEED UTILITY MAIN (IF INTERCONNECTION AC METER PV COMBINER — Q <br /> AMPACITY OF BUSBAR. METER SERVICE PANEL IS MADE HERE) DISCONNECT (IF APPLICABLE) BOX c ) <br /> W U) X H H <br /> 00 00 00 00 Zo <br /> 0 - � � <br /> SOLAR PV SYSTEM EQUIPPED BUILDINGS WITH PV SYSTEMS SHALL HAVE A nl 0 y N <br /> WITH RAPID SHUTDOWN PERMANENT LABEL LOCATED AT EACH SERVICE O O O O O O O C:) > V V <br /> EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS V J (0 LIJ Q Q <br /> TURN RAPID SHUTDOWN ARE CONNECTED OR AT AN APPROVED READILY <br /> SWITCH TO THE VISIBLE LOCATION AND SHALL INDICATE THE LOCATION O IF BREAKER O O OOR PLACARD O <br /> "OFFOWNPIONTO socae�ecmic IS USED 11 DRAWING BY: <br /> SHUT DOWN PV SYSTEM OF RAPID SHUTDOWN INITIATION DEVICES. <br /> 0 <br /> AND REDUCE (2017 NEC 690.56(C)(1)(a)] <br /> SHOCK HAZARD c <br /> IN THE ARRAY (2020 NEC 690.56(C)] (�) <br /> OR 10 IChael Honey <br /> OR PLACARD PLOT DATE: <br /> RAPID SHUTDOWN LABEL 7 January 3, 2024 <br /> SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT <br /> SWITCH FOR SWITCH <br /> (2017 NEC 690.56(C)(3)] PROJECT NUMBER: <br /> SOLAR PV SYSTEM (2020 NEC 690.56(C)(2)] <br /> 820030 <br /> LABELING NOTES SHEET NAME: <br /> 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT LABELS <br /> REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. "ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL <br /> 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED <br /> 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: <br /> 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE B PV7 <br /> HANDWRITTEN[NEC 110.211 DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />
The URL can be used to link to this page
Your browser does not support the video tag.