My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1820 SILVER LAKE RD 2025-04-21
>
Address Records
>
SILVER LAKE RD
>
1820
>
1820 SILVER LAKE RD 2025-04-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2025 8:59:57 AM
Creation date
7/30/2024 1:32:57 PM
Metadata
Fields
Template:
Address Document
Street Name
SILVER LAKE RD
Street Number
1820
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Shyamal Gounder <br />Shyvani Investments LLC <br />Plan Check Number: B2103-052, First Building Review <br />August 16, 2021 <br />19. Plans should show the connection of steel columns located on top of the retaining walls. For <br />example, the 3x3x1/4 column referenced in comment 18. R106.1.1 <br />20. See Sheet S3. Plans should show columns above and their connections to the beams. For <br />example, the HSS 3x3x1/4 and HSS 5x5x1/4 columns above landing on the W16x31 beam. <br />R106.1.1 <br />21. See Sheet S3 and A-4. It appears that the size and location of the 5x5x1/4 steel column does <br />not match Sheet A-4. R106.1.1 <br />22. See Sheet S2 and Structural Calculations Page 122. It appears that a 21-foot shear wall is <br />located on Grid Line 3.7; however, the plans are missing the shear wall callout. <br />23. See Sheet S2 and Structural Calculation Page 6 and 122. It appears that on Grid Line 3.3 a total <br />of 15-foot shear wall is shown and on Grid Line 3.7 a total of 6-foot shear wall is shown but <br />plans do not show the location of these shear walls. <br />24. It appears Detail 1/S10 that is referenced on Grid Line 2 on Sheet S4 but does not show the <br />deck framing or any anchorage to resist lateral forces. R311.5 <br />25. See Sheet S5. It appears Simpson IUS1.81/16 and IUS3.56/16 joist hangers are specified for <br />TJI 360 floor joists on Grid Line 3.7. Please clarify. <br />26. See Sheet S5. It appears that Detail 3/S11 is referenced on Grid Lines A and B but the detail is <br />not apply. <br />27. Structural Notes on Sheet S1 should specify soil pressures used for the design of the retaining <br />walls. <br />28. It is understood through correspondence with the owner that the Upper -Level roof framing is <br />being eliminated. Sheet S6 should be revised. R106.1.1 <br />29. See Page 71 of Structural Calculations. Beam should be designed for floor live loads on spans <br />selected to produce the greatest load effect at each location under consideration per IBC <br />1607.12. Plans should show connection at supports to resist any uplift. R106.1.1 <br />30. See Detail 10/S10. It appears a detail for a steel frame is shown but it is unclear the where the <br />frame is located. Plans should reference the location of the details. <br />(M 3200 Cedar Street <br />Everett, WA 98201 <br />© 425.257.8810 O <br />425.257.8857 fax <br />everetteps@everettwa.gov <br />everettwa.gov/perm its <br />Page 7 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.