Laserfiche WebLink
1/2" DCW LINE IN WALL <br />LAVATORY OR SINK <br />2"VENT, CONNECT —� <br />TO EXISTING STACK. <br />VERIFY EXACT <br />LOCATION IN FIELD. <br />I <br />BALL SHUTOFF <br />LVALVE, NP. <br />1/2" X 3/8" NOM. COMP. I <br />CHROME PLATED ANGLE <br />VALVE <br />1-1 /2" TRAP ARM AND <br />P-TRAP <br />2" WALL CLEAN -OUT AT 12" <br />ABOVE FINISHED FLOOR. <br />FINISHED FLOOR <br />PIPE UNION, TYP. <br />W <br />2" WASTE, CONNECT NOTE: ALL DEVICES, EQUIPMENT AND <br />TO EXISTING SAN. PIPING SHALL BE COVERED UNDERADA <br />VERIFY EXACT COMPLIANT INSULATION TO MAINTAIN ADA <br />LOCATION IN FIELD. COMPLIANCE PER ANSI 117. <br />INSTANTANEOUS WATER HEATER <br />NO SCALE <br />I I CONNECT TO EXISTING VENT <br />n ?"V <br />11 � PIPING OF EQUAL OR LARGER <br />II D SIZE. CONTRACTOR SHALL <br />I I I I FIELD VERIFY EXACT POINT <br />11 I I OF CONNECTION. <br />II I <br />II II <br />11 I I <br />II II <br />11 I I <br />II II <br />II II <br />11 I I <br />II II <br />I I I I <br />I I I I <br />11 I I <br />II II <br />II II <br />11 I I <br />II II <br />II III <br />II II <br />II III <br />11 I I <br />II II <br />II <br />L_1 <br />II <br />I <br />CLEANOUT II <br />II <br />II <br />II <br />II <br />II <br />II <br />II <br />WC-1 <br />A II <br />CONNECT TO EXISTING SANITARY <br />PIPING OF EQUAL OR LARGER <br />SIZE. CONTRACTOR SHALL <br />5•qN FIELD VERIFY EXACT POINT <br />OF CONNECTION. <br />2 PLUMBING ISOMETRIC <br />NO SCALE <br />PLUMBING FIXTURE AND EQUIPMENT SCHEDULE <br />PLAN <br />FIXTURE <br />ICC/ANSI Al 17.1 <br />MANUFACTURER <br />SERIES <br />TRIM <br />SERIES <br />SUPPLIES <br />TRAP / <br />DRAIN <br />CW <br />HW / <br />WASTE <br />VENT <br />WATER <br />NOTES / REMARKS <br />CODE <br />COMPLIANT # <br />WASTE <br />TEPID <br />CONSUMPTION <br />L-1 <br />LAVATORY <br />YES - ANSI Al 17.1 <br />AMERICAN STD. <br />0355.012 <br />DELTA <br />591LF-HGMHDF <br />W/STOPS <br />OFFSET <br />GRID <br />112" <br />1/2" <br />1112" <br />11/2" <br />0.5 GPM <br />1 <br />CHINA, WM <br />COMPLIANT <br />P-TRAP <br />4" CENTER SET <br />WC-1 <br />WATER CLOSET <br />YES - ANSI At 17.1 <br />AMERICAN STD. <br />2467.100 <br />— <br />— <br />W/STOPS <br />— <br />— <br />1/2' <br />— <br />4" <br />2" <br />1.1 GAL <br />W/OPEN FRONT NO LID SEAT <br />FM, PA TANK <br />COMPLIANT <br />PER FLUSH <br />WaterSense LISTED <br />LEGEND: CH = CHILD HEIGHT, CM = CEILING MOUNTED, CP = CHROME PLATED, CT = COUNTERTOP, FM = FLOOR MOUNTED, FV = FLUSH VALVE, PA = PRESSURE ASSIST, SS = STAINLESS STEEL, <br />TP = PROVIDE TRAP PRIMER (TP-1) ADJACENT TO FIXTURE, WM = WALL MOUNTED (PROVIDE WITH A FLOOR MOUNTED CONCEALED CARRIER), UCT = UNDER COUNTERTOP <br />GENERAL NOTES: <br />1. WHERE FIXTURE/EQUIPMENT MODEL NUMBERS ARE GIVEN THESE ARE FOR REFERENCE ONLY. WRITTEN <br /># WHERE NOTED THE PLUMBING FIXTURE, EQUIPMENT AND ASSOCIATED ACCESSORIES <br />SPECIFICATION REQUIREMENTS AND SCHEDULE NOTES HOLD PRECIDENCE. THE MORE STRIGENT SHALL APPLY. <br />SHALL BE ICC/ANSI At 17.1 (ADA) COMPLIANT. EXPOSED CW, HW AND W PIPING ALONG WITH <br />2. SEE ARCHITECTURAL DWGS FOR MOUNTING HEIGHTS ON ALL WALL MOUNTED FIXTURES/EQUIPMENT, <br />MIXING VALVE SHALL BE INSULATED. PIPING WITHIN CASEWORK THAT OPENS FOR FIXTURE <br />ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER ANY VALUES WITHIN THIS SCHEDULE. <br />USE IS CONSIDERED EXPOSED. <br />3. THE MINIMUM WASTE EVENT PIPE SIZE FOR BURIED PIPE SHALL BE 2". <br />4. ALL ACCESIBLE FIXTURES SHALL COMPLY WITH ICC/ANSI At 17.1 (ADA), REFERENCE ARCH DWGS FOR SPECIFIC LOCATIONS. SEE NOTES. <br />5. ALL FIXTURES AND EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. <br />SPECIFIC NOTES: <br />1. AUTOMATIC -TYPE ELECTRONIC SENSOR TRIM, BATTERY POWERED. <br />PLUMBING INSULATION SCHEDULE <br />PIPE SIZES <br />SYSTEM <br />INSULATION TYPE <br />FLUID TEMPERATURE RANGE <br />SPECIFIC NOTES <br /><7" <br />1"to 1.1/4" <br />1.112" to 3" <br />4" to 6" <br />6" and Larger <br />DOMESTIC COLD WATER <br />FLEXIBLE ELASTOMERIC OR GLASS FIBER PREFORMED PIPE INSULATION <br />— <br />112" <br />1/2" <br />1" <br />141 T0200 DEGF <br />1-1/2" <br />1-1/2" <br />2" <br />2" <br />2" <br />DOMESTIC HOT WATER AND DOMESTIC HOT WATER RECIRC <br />GLASS FIBER OR MINERAL FIBER PREFORMED PIPE INSULATION <br />< 140 DEG F <br />1" <br />1" <br />1-1/2" <br />1-1/2" <br />1-1/2" <br />GENERAL NOTES: <br />1) FOR PIPING EXPOSED TO THE OUTSIDE AMBIENT CONDITIONS OR PIPING PROVIDED WITH HEAT TRACE, INCREASE THICKNESS OF INSULATION BY 1/2". <br />2) FOR PIPING EXPOSED TO THE OUTSIDE AMBIENT CONDITIONS PROVIDE PROTECTIVE JACKET (SEE SPECIFICATIONS). <br />3) ALL INSULATION EXPOSED TO UV CONDITIONS SHALL BE PROTECTED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTRUCTIONS. <br />4) MINIMUM THERMAL CONDUCTIVITY "k" VALUE FOR FLEXIBLE ELASTOMERIC SHALL BE 0.27 AT 75 DEG. F <br />5) MINIMUM THERMAL CONDUCTIVITY "k" VALUE FOR GLASS FIBER SHALL BE 0.23 AT 75 DEG. F <br />SPECIFIC NOTES: <br />1) PROVIDE PIPE INSULATION WICKING SYSTEM ON ALL EXISTING SYTEMS THAT ARE OPERATIONAL DURING INSTALLATION. <br />OUTDOOR AIR REQUIREMENTS <br />ROOM <br />ROOM <br />NUMBER(S) <br />AREA <br />SQ. FT. <br />(Az) <br />OCCUPANCY <br />(Pz) <br />IMC MAX. <br />OCCUPANT LOAD / <br />1000 SQ. FT <br />2021 WSMC <br />REQUIRED O.A.** <br />(Rp*Pz+Ra*AzuEz <br />ROOM <br />SUPPLY <br />CFM <br />Existing <br />Unit <br />% OSA <br />ROOM <br />O.A. <br />CFM <br />MEETS <br />REQUIREMENTS <br />Rp7CFMI <br />CFM/PER P <br />FT. <br />WSMC <br />WAITING/WELCOME <br />101 <br />145 <br />2 <br />15 <br />5 <br />0.06 <br />24 <br />200 <br />15% <br />30 <br />Yes <br />TAX AREA/OPEN <br />107 <br />754 <br />4 <br />5 <br />5 <br />0.06 <br />80 <br />600 <br />15% <br />90 <br />Yes <br />**REQUIRED O.A. CALCULATION IS BASED ON Ez=0.8 <br />Ceiling supply of cool or heated air. <br />DOMESTIC WATER HEATER SCHEDULE <br />HEATING CAPACITY <br />ELEC DATA <br />ITEM <br />SERVICE <br />TANK CAP. [GAL] <br />OPERATING WEIGHT [LBS] <br />MANUFACTURER & MODEL NO. <br />NOTES <br />CONTROLS <br />ELEC OUTPUT [kW] <br />TEMP RISE ["F] <br />FLA <br />V-PH <br />EWH-1 <br />TOILET 104 <br />0 <br />4.8 <br />66 <br />20 <br />1 240-1 <br />10 <br />EEMAX AM005240T <br />1, 2, 3 <br />INTEGRAL <br />GENERAL NOTES (APPLY TO ALL PRODUCT): <br />1) CONTROLS: INTEGRAL = INTERNAL CONTROLS PROVIDED WITH UNIT, DDC = DIRECT DIGITAL CONTROLS BY DIV 23, OTHER = SEE NOTES <br />2) INSTALL WATER HEATER AND PIPING PER SELECTED MANUFACTURER'S WRIT17EN INSTRUCTIONS <br />SPECIFIC NOTES (APPLY WHERE NOTED): <br />1) ALL ELEMENTS RUN SIMULTANEOUSLY. kW AND AMPERAGE LISTED ARE FOR ALL ELEMENTS BEING ON. <br />2) PROVIDE SINGLE POINT ELECTRICAL POWER CONNECTION WITH FACTORY INSTALLED FUSED DISCONNECT FOR HEATING ELEMENTS AND CONTROLS. <br />3) WATER HEATER PROVIDED WITH INTEGRAL ASSE 1070 APPROVED MIXING VALVE WHICH ALSO PROVIDES COMPLIANCE WITH UPC 407.3. <br />�I,blc LAWRENCE <br />GROUP <br />St LOUTS <br />319 North 4th Street <br />Suite 1000 <br />St. Louis, Missouri 63102 <br />(314)231-5700 <br />PROJECTTEAM: <br />GENERAL CONTRACTOR: <br />TBD <br />PROFESSIONAL ENGINEER: <br /><:IMEG <br />IMEG <br />7600 E Orchard Road, Suite 250-S <br />Greenwood Village, CO 80111 <br />Phone: 303.796.6000 <br />MEG Project No.: 23000048.10 <br />PROFESSIONAL SEAL: <br />E <br />ob <br />P <br />"IT ta.�o�'. <br />yONAIE? <br />0 Z4.ZOZ3 <br />E,XP. o� 1 o•z oz4 <br />PROJECT TITLE' <br />0 <br />N <br />� <br />M <br />/ <br />Q <br />H <br />I— <br />W <br />LU <br />W <br />W <br />/ <br />0 O <br />W <br />Z <br />W <br />W <br />U <br />� M <br />� W <br />Q <br />Z <br />W <br />Lu <br />-J <br />DO <br />J <br />Q <br />U 06 <br />of <br />W <br />� <br />O <br />M <br />M <br />m <br />N <br />O = <br />N <br />The Professional Architect's seal afrued to this sheet <br />applies only [o the material aM items shown on this <br />sheet All dawings, instruments or other documents <br />exhibiting this be by <br />rot <br />seal shall not considered prepared <br />this architect, and this architect expressly disclaims any <br />and all responsibility for such plans, drawings or <br />documents not exhibiting this seal. <br />This dewing and details on it are the sole propertyof the <br />—haen and may he used fa„ this ape & project-ly <br />It mall not be loaned copied or rep,duced,'m-1 or <br />Zd, or for any other purpose or project without the <br />tlten consent of the architect. <br />No Description <br />Date <br />SHEETTITLE: <br />MECHANICAL AND <br />PLUMBING DETAILS <br />AND SCHEDULES <br />PROJECT NUMBER: SHEET NUMBER: <br />2021932.001 <br />D.- By. <br />ABN <br />Issue Dace: <br />May 23, 2023 <br />