LAWRENCE <br />GRILLES, REGISTERS, & DIFFUSERS SCHEDULE <br />GROUP <br />EQUIPTAG <br />TYPE FACE <br />SIZE IN. <br />MOUNTING TYPE <br />DAMPER REQUIRED <br />MATERIAL <br />MANUFACTURER & MODEL... <br />PLAN INFO <br />SPECIFIC NOTES <br />St. LOUTS <br />RG-1 <br />PERFORATED FACE CEILING RETURN GRILLE <br />24" x 24" <br />TILE CLG <br />SEE NOTES <br />STEEL <br />KRUEGER 6490/6690 <br />NECK/CFM* <br />1, 2, 3 <br />319 North 4th Street <br />Suite 1000 <br />St. Louis, Missouri 63102 <br />GENERAL NOTES: <br />(314)231-5700 <br />1. SEE PLANS FOR NECK SIZE <br />2. ALL GRDs REQUIRING DAMPERS SHALL BE EQUIPPED WITH A REMOTE BALANCING DAMPER THAT IS ADJUSTABLE THROUGH THE GRD FACE OR ANOTHER APPROVED <br />PROJECTTEAM: <br />LOCATION UNLESS SUPPLIED FROM AN ACCESSIBLE TAKE -OFF WITH LOCKING DAMPER. FACE DAMPERS SUCH AS INTEGRAL OBDs ARE NOT ACCEPTABLE. <br />GENERAL CONTRACTOR: <br />3. VERIFY GAD FINISH AND CLGMALL/SILL/FLOOR MOUNTING TYPE WITH ARCHITECT FOR EACH APPLICATION PRIOR TO ORDERING. <br />TBD <br />4. PROVIDE 4-WAY THROW FOR DIFFUSERS UNLESS OTHERWISE SHOWN ON PLANS. <br />5. PROVIDE MANUFACTURERS ROUND TO RECTANGULAR ADAPTIVE COLLAR FOR DIFFUSERS AND GRILLES AS REQUIRED, MATCH DUCT SIZE AND TYPE <br />6. MATERIAL SHALL BE STEEL UNLESS OTHERWISE INDICATED OR SPECIFIED. MATERIAL SHALL BE SUITABLE FOR INSTALLED ENVIRONMENT. FOR WET <br />PROFESSIONAL ENGINEER: <br />LOCATIONS SUCH AS LOCKER ROOMS, RESTROOMS, SHOWER ROOMS, KITCHENS, POOL ROOMS, ETC.... PROVIDE ALUMINUM IN LIEU OF THE STEEL NOTED. <br />7. WHERE MULTIPLE DIFFUSERS ARE LOCATED IN A SINGLE ROOM; FACE SIZES SHALL BE THE SAME UNLESS NOTED OTHERWISE. <br />I M <br />E G <br />8. AFTER INSTALLATION, ADJUST DIFFUSERS, REGISTERS AND GRILLES TO AIR PATTERNS INDICATED, OR AS DIRECTED, BEFORE STARTING AIR BALANCING. <br />9. CONTRACTOR SHALL ENSURE ALL NEW GRO'S PROVIDED MATCH THOSE WHICH ARE EXISTING IN TERMS OF FINISH AND VISUAL APPEARANCE. <br />IMEG <br />7600 E Orchard Road, Suite 250-S <br />' WHERE CFM IS INDICATED ON PLANS FOR RETURN AND TRANSFERS, BALANCE TO AIRFLOW INDICATED. <br />Greenwood Village, CO 80111 <br />Phone: 303.796.6000 <br />SPECIFIC NOTES: <br />MEG Project No.: 23000048.10 <br />1. PROVIDE DAMPER FOR A DUCTED RETURN/TRANSFER AIR SYSTEM THAT REQUIRES AIR BALANCE AT RETURN/TRANSFER OPENINGS AS INDICATED BY <br />PROFESSIONAL SEAL: <br />AIRFLOW (CFMs) ON DRAWINGS. <br />E <br />2. AS IDENTIFIED ON THE PLANS PROVIDE 12"x24" FACE FOR 10"x22" NECKS, PROVIDE 24"x24" FACE FOR 22"x22" NECKS <br />3. PROVIDE BACKPAN WHERE CONNECTED TO DUCT OR SOUND BOOT; WHERE NO DUCT OR SOUND BOOT IS PRESENT PROVIDE PERFORATED PANEL ONLY. <br />o <br />P <br />yONpIE? <br />0 Z4-Z Z3 <br />DUCTWORK INSULATION (WRAP & LINER) SCHEDULE <br />E'XfO ID-4t24 <br />EXPOSED <br />CONCEALED <br />SYSTEM <br />LOCATION <br />SERVICE <br />NOTE <br />MINIMUM R-VALUE <br />SPECIFIC NOTES <br />RECTANGULAR <br />ROUNDIOVAL <br />RECTANGULAR <br />ROUND/OVAL <br />MAIN <br />1" LINER <br />1" LINER <br />1"LINER <br />1" LINER <br />R-6 <br />PROJECT TITLE'. <br />RETURN <br />AIR <br />INDOOR <br />o <br />BRANCH <br />1" LINER <br />— <br />1" LINER <br />1-1/2" WRAP <br />R-6 <br />rn <br />Q <br />GENERAL NOTES: <br />CIO <br />� <br />1) MINIMUM R-VALUE BASED ON 2021 WSEC REQUIREMENTS. <br />'A` L <br />■ — <br />2) DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. LINER, WHERE USED, WILL NEED TO BE FACTORED INTO THE DUCT SIZE. <br />LU <br />3) THE INSULATION THICKNESS GIVEN MEETS OR EXCEEDS THE REQUIRED R-VALUE FOR THE BASIS OF DESIGN (JOHNS MANVILLE). INSTALLED PRODUCT SHALL <br />\ / LLJ <br />� <br />MEET OR EXCEED THE LISTED R-VALUE; INSULATION THICKNESS AND CORRESPONDING DUCT SIZE (FOR LINER) SHALL BE INCREASED FOR ALTERNATES THAT <br />r <br />iI <br />CANNOT MEET THIS THICKNESS TO PERFORMANCE CONDITION. <br />4) R-VALUES FOR WRAP SHALL BE SHOWN USING THEIR INSTALLED CONDITION RATING AS NOTED ON THE MANUFACTURER'S SPECIFICATION SHEET. <br />_ <br />U <br />5) JACKET (PVC OR METAL) SHALL BE INSTALLED AS REQUIRED BY THE SPECIFICATIONS. <br />6) FLEXIBLE DUCT SHALL BE AS NOTED IN THE "AIR DUCT ACCESSORIES" SPECIFICATION. <br />LL <br />H <br />O <br />7) DUCT WRAP IS ALLOWED TO BE BLANKET OR BOARD; CONTRACTOR OPTION. <br />W <br />J <br />8) MULTIPLE LAYERS OF WRAP OR LINER TO ACHIEVE TOTAL R-VALUE ARE ACCEPTABLE IF INSTALLED PER MANUFACTURER'S INSTRUCTIONS. <br />LU <br />DEFINITIONS: <br />m <br />EXPOSED DUCT: DUCT THAT IS EXPOSED TO VIEW IN OCCUPIED OR UNOCCUPIED SPACES THAT ARE CONDITIONED. <br />I <br />CONCEALED DUCT: DUCT THAT IS CONCEALED IN CHASES, SHAFTS, CEILING PLENUMS OR OTHER ASSEMBLY WITHIN THE INSULATED BUILDING ENVELOPE. <br />F W <br />Z <br />Z Q <br />MAIN DUCT: DUCT FROM THE AIR HANDLING UNIT TO FINAL TERMINAL TAKEOFF. <br />LU _J <br />W DO <br />J 0 <br />MAIN TO TERMINAL DUCT: THIS IS A BRANCH DUCT; TYPICALLY THE DUCT FROM THE MAIN TAKEOFF TO THE TERMINAL (VAV BOX OR EQUIVALENT). <br />TERMINAL TO GRID DUCT: THIS IS A BRANCH DUCT DOWNSTREAM OF THE TERMINAL (VAV BOX, HEAT PUMP, FAN COIL OR EQUIVALENT). <br />AX M <br />U W M <br />Of <br />OUTSIDE AIR TEMPERED: TEMPERED OUTSIDE AIR IS AIR THAT IS HEATED OR COOLED TO WITHIN 10 DEG F OF THE SPACE/SURROUNDING TEMPERATURE. <br />INDOOR: DUCT LOCATIONS WITHIN THE INSULATED BUILDING ENVELOPE. <br />W N <br />� °25 <br />fn <br />U cV <br />The Professional AhA,d is seal ehmd to this sheet <br />FAN <br />aI,eetsonlyt <br />SCHEDULE <br />mg,,ateriala�tlitemOh,,d,nonthia <br />sheet. All drawings, instruments or other documents rot <br />exhibiting this seal shall not be considered prepared by <br />this architect, and this architect expressly disclaims any <br />ITEM TYPE AREA CFM ESP DRIVE SONES MOTOR DATA OPWT MANUFACTURER NOTES CONTROLS <br />and au,eapeneibirty fe, aneh plena, d,awmga or <br />documents rwt avhmlong this seal. <br />SERVED <br />INWC <br />TYPE <br />W <br />RPM <br />V-PH <br />STRTR <br />LBS <br />&MODEL NO. <br />This tlawing and details on it are the sole property of the <br />EF-1 <br />CEILING <br />TOILET 104 <br />75 <br />0.3 <br />DIRECT <br />0.9 <br />16 <br />900 <br />115-1 <br />--- <br />20 <br />GREENHECKSP-A110 <br />1,2 <br />SWITCH <br />emb and may be used fe, this apeeme projeetenly. <br />It shall not be loaned, copied o, reproduced, In —1— <br />pad, or for any other purpose or project without the <br />NOTES: 1. PROVIDE INTEGRAL DISCONNECT SWITCH, BACKDRAFT DAMPER, VIBRATION ISOLATORS AND FLEXIBLE CONNECTION ON OUTLET. <br />wrote, mow—fthea,cbuect. <br />No Description Date <br />2. FAN SHALL BE CONTROLLED FROM LIGHT SWITCH IN RESTROOM. <br />ti <br />3 <br />m <br />w' <br />m <br />ro <br />xl <br />of <br />a <br />w <br />MECHANICAL <br />a <br />SCHEDULES <br />m <br />PROJECT NUMBER: SHEET NUMBER: <br />x2021932.001 <br />ro <br />xl <br />ore�n Bx <br />ABN <br />is:ea Dace: <br />m <br />May 23, 2023 <br />