PLUMBING FIXTURE AND DRAIN ROUGH -IN SCHEDULE
<br />MARK
<br />FIXTURE TYPE
<br />WASTE (IN)
<br />VENT (IN)
<br />CW (IN)
<br />HW (IN)
<br />NOTES
<br />WC -A
<br />WATER CLOSET - ADA "EXISTING TO REMAIN"
<br />4"
<br />2"
<br />1/2"
<br />-
<br />-
<br />LV-A
<br />LAVATORY-ADA"EXISTING TO REMAIN
<br />1-1/2"
<br />1-1/2"
<br />1/2"
<br />1/2"
<br />-
<br />KS
<br />KITCHEN SINK "EXISTING TO REMAIN"
<br />2"
<br />2"
<br />1/2"
<br />1/2"
<br />DF
<br />DRINKING FOUNTAIN "EXISTING TO REMAIN"
<br />1-1/4"
<br />1-1/4"
<br />1/2"
<br />-
<br />-
<br />HS
<br />HAND SINK
<br />1-1/2"
<br />1-1/2"
<br />1/2"
<br />112"
<br />-
<br />LS
<br />LAB SINK
<br />1-1/2"
<br />1-1/2"
<br />1/2"
<br />1/2"
<br />E-1
<br />OWNER FURNISHED -MODEL TRIMMER
<br />1-1/2"
<br />1-1/2"
<br />1/4"
<br />-
<br />E-2
<br />OWNER FURNISHED -AUTOCLAVE
<br />1-1/2"
<br />1-1/2"
<br />1/4"
<br />E-3
<br />OWNER FURNISHED- ULTRASONIC CLEANER
<br />1-1/2"
<br />1-1/2"
<br />1/4"
<br />FD
<br />FLOOR DRAIN
<br />2"
<br />2"
<br />-
<br />-
<br />-
<br />FCO
<br />FLOOR CLEANOUT
<br />NOTE 4
<br />-
<br />-
<br />-
<br />-
<br />VTR
<br />VENT THRU ROOF
<br />-
<br />-
<br />-
<br />-
<br />5
<br />GENERAL NOTES
<br />A
<br />PIPE SIZES LISTED MAY BE DIFFERENT THAN THE ACTUAL FIXTURE CONNECTION. PROVIDE BRANCH PIPE OF LISTED SIZE AND PIPE FITTINGS AND
<br />OFFSETS AS REQUIRED FOR COMPLETE INSTALLATION
<br />B
<br />PROVIDE FINAL CONNECTIONS TO ALL FIXTURES
<br />C
<br />PROVIDE WALL CLEANOUTS FOR ALL SINKS AND WATER CLOSETS
<br />NOTES
<br />1
<br />ADA COMPLIANT WHERE INDICATED ON THE ARCHITECTURAL DRAWINGS. MOUNTING HEIGHT AS INDICATED ON ARCHITECTURAL DRAWINGS.
<br />2
<br />PROVIDE TRAP PRIMER ASSEMBLY WITH NUMBER OF PORTS REQUIRED
<br />TO SERVE ADJACENT DRAINS. PROVIDE WITH SHUTOFF VALVE.
<br />3
<br />CW CONNECTION VIA TRAP PRIMER.
<br />4
<br />CLEANOUTS ARE TO BE INSTALLED EVERY 100 FEET.
<br />5
<br />SIZE AS NOTED ON DRAWINGS. WHERE APPLICABLE, VENT SIZE SHALL BE
<br />IS LARGER.
<br />AS NOTED ON
<br />THE DRAWING, 1-1/2",
<br />HALF SIZE OF WASTE OR WHICHEVER
<br />WATER AND WASTE SYSTEMS LOAD CALCULATIONS
<br />KIND OF FIXTURE
<br />NUMBER OF FIXTURES
<br />WATER SOURCE
<br />FIXTURE UNITS
<br />TOTAL
<br />WFUS
<br />HWFUS
<br />WASTE DRAINGE UNITS
<br />PER FIXTURE
<br />TOTAL DRAINAGE UNITS DFUS
<br />HS
<br />5
<br />2
<br />10
<br />7.5
<br />2
<br />10
<br />LS
<br />3
<br />2
<br />6
<br />4.5
<br />2
<br />6
<br />E-1
<br />1
<br />1
<br />1
<br />-
<br />2
<br />2
<br />E-2
<br />1
<br />1
<br />1
<br />2
<br />2
<br />E-3
<br />1
<br />1
<br />1
<br />-
<br />2
<br />2
<br />TOTAL
<br />19
<br />1 12
<br />22
<br />WATER PIPE SIZE (IN)
<br />1"
<br />PRESSURE AVAILABLE
<br />MINIMUM ALLOWABLE
<br />MAXIMUM HEIGHT
<br />SUPPLY LINE
<br />SIZING
<br />WATER PIPE LENGTH
<br />(FT)
<br />100'
<br />65
<br />25
<br />15
<br />TOTAL WSFU 31
<br />FRICTION LOSS PER FOOT
<br />33.55 PSI
<br />MAXIMUM LOADING OF WATER PIPE BASED ON 33.55 PSI DROP OVER 100 FEET AND MAX 8 FPS
<br />SIZE OF PIPE
<br />1/2"
<br />3/4"
<br />1"
<br />1-114"
<br />1-1/2"
<br />WATER LINE
<br />MAXIMUM GPM
<br />5
<br />12
<br />20
<br />30
<br />40
<br />SIZING
<br />MAXIMUM WFU
<br />5
<br />15
<br />30
<br />55
<br />85
<br />PIPING IS BASED ON THIS STATED PRESSURE AND DISTANCE, PLUMBUING CONTRACTOR SHALL FIELD VERIFY EXISTING SPACE CONDITIONS
<br />AND REPORT ANY DISCREPANCIES TO THHE BUILDING OWNER.COPPER TUBING TYPE M, L, K.
<br />MAXIMUM LOADING OF DRAINAGE & VENT PIPE
<br />SIZE OF PIPE 1-1/2" 2" 3" 4" 5"
<br />WASTE
<br />MAXIMUM UNITS DRAINAGE PIPE
<br />LINE
<br />SIZING
<br />VERTICAL
<br />2
<br />16
<br />48
<br />256
<br />600
<br />HORIZONTAL
<br />1
<br />8
<br />35
<br />216
<br />428
<br />VENT PIPING
<br />8
<br />24
<br />84
<br />256
<br />600
<br />BASED ON 1/4" PER FOOT SLOPE, MULTIPLY BY 0.8 FOR 1/8" SLOPE
<br />WATER HEATER SIZING CALCULATION
<br />FIXTURE
<br />HW FLOW RATE (GPH)
<br />QUANTITY
<br />TOTAL FLOW RATE (GPH)
<br />HAND SINK
<br />5
<br />5
<br />25
<br />LAB SINK
<br />5
<br />3
<br />15
<br />TOTAL HW FLOW RATE (GPH)
<br />40
<br />DEMAND FACTOR
<br />0.50
<br />STORAGE FACTOR
<br />1.00
<br />PROBABLE DEMAND
<br />20.00
<br />REQUIRED STORAGE (GAL)
<br />40.00
<br />HOT WATER REQUIRED (GAL)
<br />60.00
<br />APPROVED PIPE MATERIALS FOR DRAIN, WASTE, VENT PIPE AND FITTINGS
<br />UNDERGROUND DRAIN,
<br />ABOVEGROUND DRAIN,
<br />BUILDING SEWER PIPE AND
<br />MATERIAL
<br />WASTE, VENT PIPE AND
<br />WASTE, VENT PIPE AND
<br />REFERENCED STANDARD(S) PIPE
<br />REFERENCED STANDARD(S) FITTINGS
<br />FITTINGS
<br />FITTINGS
<br />FITTINGS
<br />X
<br />ABS (Schedule 40)
<br />X
<br />X
<br />ASTM D2661, ASTM D2680
<br />ASTM D2661, ASTM D2680
<br />Copper and Copper Alloys (Type
<br />X
<br />X
<br />X
<br />ASTM B43, ASTM B75, ASTM B251, ASTM
<br />ASME B16.23, ASME 616.29
<br />DWV)
<br />B302, ASTM B306
<br />Galvanized Malleable Iron
<br />-
<br />X
<br />-
<br />-
<br />ASME B16.3
<br />PVC (Schedule 40)
<br />X
<br />X
<br />X
<br />ASTM D1785, ASTM D2665, ASTM F794
<br />ASTM D2665, ASTM F794, ASTM F1866
<br />NOTE:
<br />SOLVENT CEMENT JOINTS TO BE IN ACCORDANCE WITH SECTION 705.5.2 OF THE SEATTLE PLUMBING CODE (SPC) AND ASTM F656 FOR PRIMER AND ASTM D2564 FOR SOLVENT CEMENTS. TYPICAL.
<br />PIPE MATERIALS FOR BUILDING SUPPLY AND WATER DISTRIBUTION PIPING AND FITTINGS
<br />MATERIAL
<br />BUILDING DISTRIBUTION PIPE
<br />WATER DISTRIBUTION PIPE
<br />REFERENCED STANDARD(S)
<br />REFERENCED STANDARD(S) FITTINGS
<br />AND FITTINGS
<br />AND FITTINGS
<br />PIPE
<br />ASTM B42, ASTM B43, ASTM
<br />Copper and Copper Alloys
<br />X
<br />X
<br />B75, ASTM B88, ASTM B135,
<br />ASME B16.15, ASME B16.18, ASME B16.22,
<br />ASTM B251, ASTM B302, ASTM
<br />ASME B16.26, ASME B16.51
<br />B447
<br />ASTM F876, ASTM F877, CSA
<br />ASSE 1061, ASTM F877, ASTM F1807,
<br />PEX
<br />X
<br />X
<br />B137.5, AWWA C904
<br />ASTM F1960, ASTM F1961, ASTM F2080,
<br />ASTM F2159, ASTM F2735, CSA B137.5
<br />PVC
<br />X
<br />_
<br />ASTM D1785,ASTM D2241,
<br />ASTM D2464,ASTM D2466,ASTM D2467,
<br />AW WA C900
<br />ASTM F1970
<br />WATER HEATER SCHEDULE
<br />MANUFACTURER/
<br />GALLONS
<br />RECOVERY
<br />WATER
<br />DIMENSION DxH
<br />OPERATING
<br />MARK
<br />AREA SERVED
<br />MODEL NO.
<br />(GAL)
<br />BTUH
<br />V / PH.
<br />(GAL)
<br />RUNOUT (IN)
<br />(INxIN)
<br />WEIGHT (LBS)
<br />NOTES
<br />WH-1
<br />HS&LS
<br />AO SMITH
<br />60
<br />6,000 WATTS
<br />20813
<br />154
<br />27-3/4"Dx15A5-1/2 x
<br />960
<br />SET AT 140 DEG F
<br />NOTES:
<br />HEATER ELEMENTS ARE SIMULTANEOUS
<br />CIRCULATION PUMP SCHEDULE
<br />MANUFACTURE
<br />PUMP
<br />MOTOR
<br />MARK
<br />LOCATION
<br />SYSTEM SERVED
<br />R / MODEL NO.
<br />NOTES
<br />TYPE
<br />FLOW (GPM)
<br />HEAD (FT)
<br />HP/W
<br />V/PH
<br />CONTROL PUMP W/
<br />CP
<br />WATER
<br />WH-1
<br />BELL &
<br />DOMESTIC
<br />5
<br />15
<br />116
<br />115/1
<br />AQUASTAEFOR 125
<br />HEATER
<br />GOSSETT
<br />CIRCULATOR
<br />(ADJUSTABLE)
<br />NOTES:
<br />1- PROVIDE WITH BRONZE BODY CONSTRUCTION
<br />DOMESTIC WATER EXPANSION TANK SCHEDULE
<br />PHYSICAL
<br />SYSTEM
<br />MANUFACTURER/
<br />TANKVOLUME
<br />ACCEPTANCE
<br />SYSTEM CONN.
<br />SIZE (DIAxL)
<br />WEIGHT (LBS)
<br />MARK
<br />LOCATION
<br />SERVED
<br />MODEL NO.
<br />(GAL)
<br />FACTOR
<br />(IN)
<br />NOTES
<br />(INxIN)
<br />WHEN FULL
<br />ET
<br />JANITOR-119
<br />WH-1
<br />AMTROLST-12C
<br />6.4
<br />0.5
<br />3/4"
<br />12"DIAx 18
<br />81.3
<br />1
<br />NOTE: EXPANSION TANK SHALL BE DELIVERED TO THE SITE PRE -CHARGED TO OPERATING PRESSURE. CONTRACTOR SHALL COORDINATE PRIOR TO ORDERING. PROVIDE
<br />SEISMIC BRACING AND ASME RATINGS.
<br />PIPING SYSTEMS INSULATION SCHEDULE
<br />TYPE OF PIPE
<br />INSTALLATION LOCATION
<br />INSULATION TYPE
<br />PIPE SIZE (INCH)
<br />INSULATION
<br />THICKNESS (INCH)
<br />NOTES
<br />INSIDE BUILDING ENVELOPE
<br />FIBERGLASS
<br />ALL SIZES
<br />1"THICK
<br />1
<br />OUTSIDE BUILDING
<br />MULTIPLE LAYERS FOR
<br />COLD PLUMBING PIPING
<br />ENVELOPE AND BURIED
<br />ELASTOMERIC
<br />ALL SIZES
<br />1-1/2" TOTAL
<br />1,3
<br />THICKNESS
<br />IN TRENCHES AND
<br />CELLULAR GLASS
<br />ALL SIZES
<br />1"THICK
<br />2
<br />UTILIDORS
<br />1-1/4INCH AND
<br />SMALLER
<br />1"THICK
<br />INSIDE BUILDING ENVELOPE
<br />FIBERGLASS
<br />1-1/2INCH AND
<br />1-1/2"THICK
<br />1
<br />LARGER
<br />HOT PLUMBING PIPING
<br />OUTSIDE BUILDING
<br />ELASTOMERIC
<br />ALL SIZES
<br />1-1/2" THICK
<br />1
<br />ENVELOPE AND BURIED
<br />IN TRENCHES AND
<br />CELLULAR GLASS
<br />ALL SIZES
<br />1-1/2" THICK
<br />1,3
<br />UTILIDORS
<br />NOTES:
<br />1-INCLUDE POLYETHYLENE TUBING.
<br />2-INCLUDE MULTI -PLY LAMINATE JACKET.
<br />3-INCLUDE FACTORY APPLIED WEATHER PROOF JACKET OR MANUFACTURER RECOMMENDED COATING.
<br />�Z'wJ
<br />V
<br />Y
<br />W
<br />•
<br />Z
<br />Q
<br />D
<br />w
<br />31620 23rd Ave S
<br />Federal Way, WA 98003
<br />Linda@Burman.Design
<br />253.508.2658
<br />00
<br />O
<br />N
<br />O
<br />O
<br />Q
<br />J
<br />F-
<br />W
<br />Z w
<br />LLI >
<br />� w
<br />LLI Lu
<br />Z j
<br />LLI Q
<br />2
<br />Q �
<br />rn
<br />I`
<br />N
<br />O
<br />JOB NO: ----
<br />ISSUE DATE
<br />P S BUR4t
<br />WAS 9/
<br />H
<br />Ee
<br />420�25�0��.
<br />SS ONAL 8�
<br />-ZT-7
<br />SCHEDULES
<br />P0.3
<br />
|