PLUMBING FIXTURE AND DRAIN ROUGH -IN SCHEDULE <br />MARK <br />FIXTURE TYPE <br />WASTE (IN) <br />VENT (IN) <br />CW (IN) <br />HW (IN) <br />NOTES <br />WC -A <br />WATER CLOSET - ADA "EXISTING TO REMAIN" <br />4" <br />2" <br />1/2" <br />- <br />- <br />LV-A <br />LAVATORY-ADA"EXISTING TO REMAIN <br />1-1/2" <br />1-1/2" <br />1/2" <br />1/2" <br />- <br />KS <br />KITCHEN SINK "EXISTING TO REMAIN" <br />2" <br />2" <br />1/2" <br />1/2" <br />DF <br />DRINKING FOUNTAIN "EXISTING TO REMAIN" <br />1-1/4" <br />1-1/4" <br />1/2" <br />- <br />- <br />HS <br />HAND SINK <br />1-1/2" <br />1-1/2" <br />1/2" <br />112" <br />- <br />LS <br />LAB SINK <br />1-1/2" <br />1-1/2" <br />1/2" <br />1/2" <br />E-1 <br />OWNER FURNISHED -MODEL TRIMMER <br />1-1/2" <br />1-1/2" <br />1/4" <br />- <br />E-2 <br />OWNER FURNISHED -AUTOCLAVE <br />1-1/2" <br />1-1/2" <br />1/4" <br />E-3 <br />OWNER FURNISHED- ULTRASONIC CLEANER <br />1-1/2" <br />1-1/2" <br />1/4" <br />FD <br />FLOOR DRAIN <br />2" <br />2" <br />- <br />- <br />- <br />FCO <br />FLOOR CLEANOUT <br />NOTE 4 <br />- <br />- <br />- <br />- <br />VTR <br />VENT THRU ROOF <br />- <br />- <br />- <br />- <br />5 <br />GENERAL NOTES <br />A <br />PIPE SIZES LISTED MAY BE DIFFERENT THAN THE ACTUAL FIXTURE CONNECTION. PROVIDE BRANCH PIPE OF LISTED SIZE AND PIPE FITTINGS AND <br />OFFSETS AS REQUIRED FOR COMPLETE INSTALLATION <br />B <br />PROVIDE FINAL CONNECTIONS TO ALL FIXTURES <br />C <br />PROVIDE WALL CLEANOUTS FOR ALL SINKS AND WATER CLOSETS <br />NOTES <br />1 <br />ADA COMPLIANT WHERE INDICATED ON THE ARCHITECTURAL DRAWINGS. MOUNTING HEIGHT AS INDICATED ON ARCHITECTURAL DRAWINGS. <br />2 <br />PROVIDE TRAP PRIMER ASSEMBLY WITH NUMBER OF PORTS REQUIRED <br />TO SERVE ADJACENT DRAINS. PROVIDE WITH SHUTOFF VALVE. <br />3 <br />CW CONNECTION VIA TRAP PRIMER. <br />4 <br />CLEANOUTS ARE TO BE INSTALLED EVERY 100 FEET. <br />5 <br />SIZE AS NOTED ON DRAWINGS. WHERE APPLICABLE, VENT SIZE SHALL BE <br />IS LARGER. <br />AS NOTED ON <br />THE DRAWING, 1-1/2", <br />HALF SIZE OF WASTE OR WHICHEVER <br />WATER AND WASTE SYSTEMS LOAD CALCULATIONS <br />KIND OF FIXTURE <br />NUMBER OF FIXTURES <br />WATER SOURCE <br />FIXTURE UNITS <br />TOTAL <br />WFUS <br />HWFUS <br />WASTE DRAINGE UNITS <br />PER FIXTURE <br />TOTAL DRAINAGE UNITS DFUS <br />HS <br />5 <br />2 <br />10 <br />7.5 <br />2 <br />10 <br />LS <br />3 <br />2 <br />6 <br />4.5 <br />2 <br />6 <br />E-1 <br />1 <br />1 <br />1 <br />- <br />2 <br />2 <br />E-2 <br />1 <br />1 <br />1 <br />2 <br />2 <br />E-3 <br />1 <br />1 <br />1 <br />- <br />2 <br />2 <br />TOTAL <br />19 <br />1 12 <br />22 <br />WATER PIPE SIZE (IN) <br />1" <br />PRESSURE AVAILABLE <br />MINIMUM ALLOWABLE <br />MAXIMUM HEIGHT <br />SUPPLY LINE <br />SIZING <br />WATER PIPE LENGTH <br />(FT) <br />100' <br />65 <br />25 <br />15 <br />TOTAL WSFU 31 <br />FRICTION LOSS PER FOOT <br />33.55 PSI <br />MAXIMUM LOADING OF WATER PIPE BASED ON 33.55 PSI DROP OVER 100 FEET AND MAX 8 FPS <br />SIZE OF PIPE <br />1/2" <br />3/4" <br />1" <br />1-114" <br />1-1/2" <br />WATER LINE <br />MAXIMUM GPM <br />5 <br />12 <br />20 <br />30 <br />40 <br />SIZING <br />MAXIMUM WFU <br />5 <br />15 <br />30 <br />55 <br />85 <br />PIPING IS BASED ON THIS STATED PRESSURE AND DISTANCE, PLUMBUING CONTRACTOR SHALL FIELD VERIFY EXISTING SPACE CONDITIONS <br />AND REPORT ANY DISCREPANCIES TO THHE BUILDING OWNER.COPPER TUBING TYPE M, L, K. <br />MAXIMUM LOADING OF DRAINAGE & VENT PIPE <br />SIZE OF PIPE 1-1/2" 2" 3" 4" 5" <br />WASTE <br />MAXIMUM UNITS DRAINAGE PIPE <br />LINE <br />SIZING <br />VERTICAL <br />2 <br />16 <br />48 <br />256 <br />600 <br />HORIZONTAL <br />1 <br />8 <br />35 <br />216 <br />428 <br />VENT PIPING <br />8 <br />24 <br />84 <br />256 <br />600 <br />BASED ON 1/4" PER FOOT SLOPE, MULTIPLY BY 0.8 FOR 1/8" SLOPE <br />WATER HEATER SIZING CALCULATION <br />FIXTURE <br />HW FLOW RATE (GPH) <br />QUANTITY <br />TOTAL FLOW RATE (GPH) <br />HAND SINK <br />5 <br />5 <br />25 <br />LAB SINK <br />5 <br />3 <br />15 <br />TOTAL HW FLOW RATE (GPH) <br />40 <br />DEMAND FACTOR <br />0.50 <br />STORAGE FACTOR <br />1.00 <br />PROBABLE DEMAND <br />20.00 <br />REQUIRED STORAGE (GAL) <br />40.00 <br />HOT WATER REQUIRED (GAL) <br />60.00 <br />APPROVED PIPE MATERIALS FOR DRAIN, WASTE, VENT PIPE AND FITTINGS <br />UNDERGROUND DRAIN, <br />ABOVEGROUND DRAIN, <br />BUILDING SEWER PIPE AND <br />MATERIAL <br />WASTE, VENT PIPE AND <br />WASTE, VENT PIPE AND <br />REFERENCED STANDARD(S) PIPE <br />REFERENCED STANDARD(S) FITTINGS <br />FITTINGS <br />FITTINGS <br />FITTINGS <br />X <br />ABS (Schedule 40) <br />X <br />X <br />ASTM D2661, ASTM D2680 <br />ASTM D2661, ASTM D2680 <br />Copper and Copper Alloys (Type <br />X <br />X <br />X <br />ASTM B43, ASTM B75, ASTM B251, ASTM <br />ASME B16.23, ASME 616.29 <br />DWV) <br />B302, ASTM B306 <br />Galvanized Malleable Iron <br />- <br />X <br />- <br />- <br />ASME B16.3 <br />PVC (Schedule 40) <br />X <br />X <br />X <br />ASTM D1785, ASTM D2665, ASTM F794 <br />ASTM D2665, ASTM F794, ASTM F1866 <br />NOTE: <br />SOLVENT CEMENT JOINTS TO BE IN ACCORDANCE WITH SECTION 705.5.2 OF THE SEATTLE PLUMBING CODE (SPC) AND ASTM F656 FOR PRIMER AND ASTM D2564 FOR SOLVENT CEMENTS. TYPICAL. <br />PIPE MATERIALS FOR BUILDING SUPPLY AND WATER DISTRIBUTION PIPING AND FITTINGS <br />MATERIAL <br />BUILDING DISTRIBUTION PIPE <br />WATER DISTRIBUTION PIPE <br />REFERENCED STANDARD(S) <br />REFERENCED STANDARD(S) FITTINGS <br />AND FITTINGS <br />AND FITTINGS <br />PIPE <br />ASTM B42, ASTM B43, ASTM <br />Copper and Copper Alloys <br />X <br />X <br />B75, ASTM B88, ASTM B135, <br />ASME B16.15, ASME B16.18, ASME B16.22, <br />ASTM B251, ASTM B302, ASTM <br />ASME B16.26, ASME B16.51 <br />B447 <br />ASTM F876, ASTM F877, CSA <br />ASSE 1061, ASTM F877, ASTM F1807, <br />PEX <br />X <br />X <br />B137.5, AWWA C904 <br />ASTM F1960, ASTM F1961, ASTM F2080, <br />ASTM F2159, ASTM F2735, CSA B137.5 <br />PVC <br />X <br />_ <br />ASTM D1785,ASTM D2241, <br />ASTM D2464,ASTM D2466,ASTM D2467, <br />AW WA C900 <br />ASTM F1970 <br />WATER HEATER SCHEDULE <br />MANUFACTURER/ <br />GALLONS <br />RECOVERY <br />WATER <br />DIMENSION DxH <br />OPERATING <br />MARK <br />AREA SERVED <br />MODEL NO. <br />(GAL) <br />BTUH <br />V / PH. <br />(GAL) <br />RUNOUT (IN) <br />(INxIN) <br />WEIGHT (LBS) <br />NOTES <br />WH-1 <br />HS&LS <br />AO SMITH <br />60 <br />6,000 WATTS <br />20813 <br />154 <br />27-3/4"Dx15A5-1/2 x <br />960 <br />SET AT 140 DEG F <br />NOTES: <br />HEATER ELEMENTS ARE SIMULTANEOUS <br />CIRCULATION PUMP SCHEDULE <br />MANUFACTURE <br />PUMP <br />MOTOR <br />MARK <br />LOCATION <br />SYSTEM SERVED <br />R / MODEL NO. <br />NOTES <br />TYPE <br />FLOW (GPM) <br />HEAD (FT) <br />HP/W <br />V/PH <br />CONTROL PUMP W/ <br />CP <br />WATER <br />WH-1 <br />BELL & <br />DOMESTIC <br />5 <br />15 <br />116 <br />115/1 <br />AQUASTAEFOR 125 <br />HEATER <br />GOSSETT <br />CIRCULATOR <br />(ADJUSTABLE) <br />NOTES: <br />1- PROVIDE WITH BRONZE BODY CONSTRUCTION <br />DOMESTIC WATER EXPANSION TANK SCHEDULE <br />PHYSICAL <br />SYSTEM <br />MANUFACTURER/ <br />TANKVOLUME <br />ACCEPTANCE <br />SYSTEM CONN. <br />SIZE (DIAxL) <br />WEIGHT (LBS) <br />MARK <br />LOCATION <br />SERVED <br />MODEL NO. <br />(GAL) <br />FACTOR <br />(IN) <br />NOTES <br />(INxIN) <br />WHEN FULL <br />ET <br />JANITOR-119 <br />WH-1 <br />AMTROLST-12C <br />6.4 <br />0.5 <br />3/4" <br />12"DIAx 18 <br />81.3 <br />1 <br />NOTE: EXPANSION TANK SHALL BE DELIVERED TO THE SITE PRE -CHARGED TO OPERATING PRESSURE. CONTRACTOR SHALL COORDINATE PRIOR TO ORDERING. PROVIDE <br />SEISMIC BRACING AND ASME RATINGS. <br />PIPING SYSTEMS INSULATION SCHEDULE <br />TYPE OF PIPE <br />INSTALLATION LOCATION <br />INSULATION TYPE <br />PIPE SIZE (INCH) <br />INSULATION <br />THICKNESS (INCH) <br />NOTES <br />INSIDE BUILDING ENVELOPE <br />FIBERGLASS <br />ALL SIZES <br />1"THICK <br />1 <br />OUTSIDE BUILDING <br />MULTIPLE LAYERS FOR <br />COLD PLUMBING PIPING <br />ENVELOPE AND BURIED <br />ELASTOMERIC <br />ALL SIZES <br />1-1/2" TOTAL <br />1,3 <br />THICKNESS <br />IN TRENCHES AND <br />CELLULAR GLASS <br />ALL SIZES <br />1"THICK <br />2 <br />UTILIDORS <br />1-1/4INCH AND <br />SMALLER <br />1"THICK <br />INSIDE BUILDING ENVELOPE <br />FIBERGLASS <br />1-1/2INCH AND <br />1-1/2"THICK <br />1 <br />LARGER <br />HOT PLUMBING PIPING <br />OUTSIDE BUILDING <br />ELASTOMERIC <br />ALL SIZES <br />1-1/2" THICK <br />1 <br />ENVELOPE AND BURIED <br />IN TRENCHES AND <br />CELLULAR GLASS <br />ALL SIZES <br />1-1/2" THICK <br />1,3 <br />UTILIDORS <br />NOTES: <br />1-INCLUDE POLYETHYLENE TUBING. <br />2-INCLUDE MULTI -PLY LAMINATE JACKET. <br />3-INCLUDE FACTORY APPLIED WEATHER PROOF JACKET OR MANUFACTURER RECOMMENDED COATING. <br />�Z'wJ <br />V <br />Y <br />W <br />• <br />Z <br />Q <br />D <br />w <br />31620 23rd Ave S <br />Federal Way, WA 98003 <br />Linda@Burman.Design <br />253.508.2658 <br />00 <br />O <br />N <br />O <br />O <br />Q <br />J <br />F- <br />W <br />Z w <br />LLI > <br />� w <br />LLI Lu <br />Z j <br />LLI Q <br />2 <br />Q � <br />rn <br />I` <br />N <br />O <br />JOB NO: ---- <br />ISSUE DATE <br />P S BUR4t <br />WAS 9/ <br />H <br />Ee <br />420�25�0��. <br />SS ONAL 8� <br />-ZT-7 <br />SCHEDULES <br />P0.3 <br />