Laserfiche WebLink
GENERAL <br />EXISTING MECHANICAL TO <br />BE REMOVED <br />EXISTING MECHANICAL TO <br />REMAIN <br />MATCHLINE OR PROPERTY <br />LINE <br />ENLARGED PLAN BOUNDARY <br />1 DETAIL/PLAN IDENTIFIER <br />M 1 .01 <br />A <br />M 1 .01 <br />A <br />M1.01 <br />0 <br />O <br />O <br />AHU-01 <br />a <br />SECTION IDENTIFIER <br />ELEVATION IDENTIFIER <br />REVISION CALLOUT <br />KEYED NOTE TAG <br />CODED NOTE <br />MECHANICAL EQUIPMENT <br />TAG <br />INVERT ELEVATION OR FOG <br />CONTROLS (PLAN VIEW) <br />O <br />THERMOSTAT OR <br />TU-xx <br />TEMPERATURE SENSOR <br />SENSOR: SHOWN WITH GUARD <br />(Dc <br />(TYPICAL ALL SENSORS) <br />O <br />HUMIDISTAT OR HUMIDITY <br />SENSOR <br />co <br />CARBON MONOXIDE SENSOR <br />co <br />CARBON DIOXIDE SENSOR <br />AQ <br />INDOOR AIR QUALITY SENSOR <br />�x <br />SWITCH BY MECHANICAL <br />ELECTRICAL PROVISIONS FOR MECHANICAL WORK <br />LOCATION OF STARTER, <br />DISCONNECT & CONTROLS <br />VFD VARIABLE FREQUENCY DRIVE <br />HT HT HEAT TRACE BETWEEN <br />SYMBOLS OR END OF RUN <br />ACCESS <br />ACCESS DOOR (SPECIFIED <br />OR AS SHOWN ON DWGS) <br />MECHANICAL ACCESS <br />(SPECIFIED OR AS SHOWN <br />ON DWGS) <br />PIPING <br />PIPE ELBOW UP OR <br />PIPE TEE UP AND DOWN <br />PIPE ELBOW DOWN <br />PIPE TEE UP <br />PIPE TEE DOWN <br />PIPE RISE <br />PIPE CAP <br />PIPE PLUG <br />FLOW DIRECTION <br />1 PIPE BREAK <br />c CONDENSATE DRAIN <br />SOIL AND WASTE WATER PIPING SYSTEM <br />SANITARY SEWER/WASTE <br />UNDERGROUND <br />SANITARY SEWER/WASTE <br />ABOVE GROUND <br />VENT PIPING <br />X' VTR <br />VENT THRU ROOF <br />(INCLUDE SIZE) <br />FLOOR DRAIN/FUNNEL <br />FLOOR DRAIN <br />WCO <br />CLEANOUT — FREE <br />STANDING WALL MOUNTED <br />FCO <br />CLEANOUT — FLUSH WITH <br />FLOOR <br />A <br />ACID WASTE <br />DOMESTIC WATER PIPING SYSTEM <br />TP <br />O <br />0 <br />DOMESTIC COLD WATER <br />DOMESTIC HOT WATER <br />DOMESTIC HOT WATER <br />CIRCULATION <br />TRAP PRIMER WATER <br />WATER METER <br />BASKET STRAINER <br />HOSE BIBB/WALL HYDRANT <br />C TRAP PRIMER BOX <br />VALVES <br />VALVE: GATE, BALL, <br />�a BUTTERFLY (REFER TO <br />SPECIFICATIONS) <br />GLOBE VALVE <br />SOLENOID VALVE <br />fv CHECK VALVE <br />BALANCING VALVE <br />PIPING SPECIALTIES <br />UNION <br />FLANGE <br />FLEX CONNECTOR <br />THERMAL/SEISMIC <br />FLEXIBLE LOOP <br />THERMAL EXPANSION <br />JOINT <br />NATURAL GAS PIPING SYSTEM <br />G LOW PRESSURE <br />NATURAL GAS PIPING <br />MPG MEDIUM PRESSURE <br />NATURAL GAS PIPING <br />GAS COCK <br />PRESSURE REGULATOR <br />PRESSURE REGULATOR <br />WITH VENT <br />SEISMIC GAS SHUT—OFF <br />—� GAS PRESSURE REDUCING <br />VALVE WITH VENT <br />Z <br />0 <br />� <br />Vl <br />W <br />• <br />z <br />a <br />D <br />31620 23rd Ave S <br />Federal Way, WA 98003 <br />Linda@Burman.Design <br />,)Aq AnA FAA <br />0 <br />0 <br />N <br />0 <br />rn <br />a <br />J <br />I— ~ <br />w <br />Z w <br />W > <br />Q W <br />W U) <br />Z j <br />W Q <br />2 <br />Q � <br />_rn <br />N <br />0 <br />JOB NO: ---- <br />ISSUE DATE <br />ap S sUR,y <br />o `i x -1 <br />p z <br />-2 <br />LEGEND <br />P0.2 <br />