My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10217 19TH AVE SE DR SHARMA 2024-11-15
>
Address Records
>
19TH AVE SE
>
10217
>
DR SHARMA
>
10217 19TH AVE SE DR SHARMA 2024-11-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2024 7:58:08 AM
Creation date
8/2/2024 2:49:48 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10217
Tenant Name
DR SHARMA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PermitFA09 FIRE ALARM TENANT IMPROVEMENT <br />Site Address: 10217 191h Ave SE Ste 101 <br />Applicann t: StevenvenMascorro <br />Application Date: 09/19/2023 <br />Description: Fire Alarm System, Tenant Improvement. <br />12) <br />adding (Date: 09/26/2023 <br />Devices EVERETT, WASHINGTON <br />EVERETT rvenen <br />Review Date: view Status: 1st Review by City & Peer Reviewers <br />ReEverett Fire Dept. Permit Review <br />Status: Approved <br />Reviewed By: KBrown <br />10: <br />SHEET # SHEET TITLE AM <br />FA-01 I SYSTEM INFORMATION <br />FA-02 TYPICAL WIRING, MOUNTING DETAILS & CALCULATIONS <br />FA-03 PARTIAL FIRST FLOOR FIRE ALARM LAYOUT <br />SHEETINDEX <br />TYPE OF WORK: BUILDING FIRE ALARM SYSTEM <br />ADD (1) NEW NAC WITH (5) NEW HORN/STROBES & (6) STROBES TO EXISTING FIRE ALARM SYSTEM <br />SCOPE OF WORK <br />WIRE SCHEDULE AND CONDUIT FILL CHART <br />WIRE DESIGNATION <br />SYMBOL <br />DESCRIPTION <br />NUMBER OF CONDUCTORS SIZE <br />TYPE COLOR CODE <br />D <br />DATA LINE - ADDRESSABLE LOOP <br />TWISTED PAIR WITH SHIELD #16 <br />FPL/FPLR RED (JACKET) <br />S <br />SIGNALING CIRCUIT - FEED <br />TWO #14 <br />FPL/FPLR RED (JACKET) <br />S' <br />SIGNALING CIRCUIT - RETURN <br />TWO #14 <br />FPL/FPLR RED (JACKET) <br />CONDUIT <br />FILL CHART <br />NO. OF CONDUCTORS VOLTS <br />WIRE SIZE TYPE DIMENSIONS <br />AREA <br />TWO 600V <br />#12 AWG THHN/THWN .244 <br />O.D. .0467 <br />TWO 600V <br />#14 AWG THHN/THWN TWISTED .210 <br />O.D. .0346 <br />TWO CONDUCTOR 300V <br />#18 AWG FPL TW CABLE .156 <br />O.D. .0191 <br />CONDUIT FILL <br />CALCULATE THE TOTAL AREA <br />OF THE WIRE BEING RUN IN THE CONDUIT <br />FROM THE TABLE <br />ABOVE. CHOOSE THE SIZE OF <br />CONDUIT BASED ON THE MAXIMUM FILL <br />DIMENSION FROM <br />THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE <br />WIRE. <br />CONDUIT SIZE MAXIMUM FILL <br />1/2" <br />.12 SQUARE INCH <br />3/4" <br />.21 SQUARE INCH <br />1" <br />.34 SQUARE INCH <br />1-1/4" <br />.60 SQUARE INCH <br />1-12" <br />.82 SQUARE INCH <br />2' <br />1.34 SQUARE INCH <br />FIGURES ARE BASED ON 40% <br />CONDUIT FILL AND ARE TAKEN FROM N.E.C., <br />CHP. 9, TABLE 4. <br />SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED <br />THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END <br />FOR SILENT KNIGHT SYSTEM: <br />DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED <br />WITH DEVICES ADDRESS. <br />1. ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE <br />THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 80" TO BOTTOM. NFPA 72, <br />2016 EDITION, ALLOWS 80"-96" FOR VISUAL DEVICES (CH. 4-4.4) AND <br />REQUIRES A MINIMUM OF 90" TO TOP FOR AUDIBLE DEVICES <br />OR 6" FROM CEILING, WHICHEVER IS LOWER (CH. 4-3.5). <br />FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE NOTIFICATION SHALL BE <br />WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24" FROM CEILING <br />TO TOP OF LENS FOR 110cd (CH. 4-4.4.3.2) <br />2. ALL EQUIPMENT SHALL BE U.L. LISTED. <br />3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT <br />REQUIRE SERVICING, TROUBLE SHOOTING, ETC. <br />4. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT <br />PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC., TEL <br />(206)622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL <br />PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS <br />SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. <br />5. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER THAN <br />3 FEET (900mm) FROM AN AIR SUPPLY DIFFUSER. <br />6. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE <br />FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS <br />OF THE AUTHORITIES HAVING JURISDICTION. <br />7. ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, <br />GUTTERS, JUNCTION BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED <br />AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER <br />TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL <br />INFORMATION. SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED <br />BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. <br />8. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH APPROVED SMOKE. <br />9. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE <br />SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM <br />CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING <br />AND INDICATING DEVICE CIRCUITS. <br />10. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE <br />LOOPED THROUGH DEVICES. ALL SPLICED WIRE POSSESING SHIELDS SHALL HAVE <br />SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. <br />11. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE <br />AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER. <br />12. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED <br />PER MANUFACTURER'S SPECIFICATIONS. <br />13. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED (UUJS). <br />14. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, <br />NEC AND CONTRACT DRAWINGS <br />15. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ <br />16. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S. TECHNICIANS <br />17. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND <br />CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. <br />FIELD TECHNICIANS <br />18. A SET OF AS BUILT DRAWINGS TO BE TURNED INTO GSSINC WITH APPROPRIATE <br />COLOR CODED MARKUP DRAWINGS (SEE SYMBOL LEGEND FOR COLOR CODING). <br />QUANTITY <br />SYMBOL <br />DESCRIPTION <br />MODEL <br />MANUFACTURER <br />BACKBOX <br />MOUNTING HEIGHT <br />(1)E <br />FACP 1 <br />E <br />FIRE ALARM <br />CONTROL PANEL <br />(EXISTING) <br />SK-5820 <br />SILENT KNIGHT <br />- <br />66" A.F.F. <br />TO TOP <br />(6)E <br />OE <br />SMOKE DETECTOR <br />(EXISTIREMOTE <br />EXISTING <br />- <br />yS/ DI GE RING <br />CEILING <br />1 <br />ACn <br />BOOSTER <br />POWER SUPPLY <br />SK-5495 <br />SILENT KNIGHT <br />- <br />66" A.F.F. <br />TO TOP <br />(1)E <br />xP <br />%RE <br />FIRE ALARM <br />HORN/STROBE <br />(WEATHERPROOF) <br />P2RK <br />SYSTEM SENSOR <br />INCLUDED <br />80" A.F.F. <br />TO BOTTOM <br />OR U.O.S. <br />(3)E <br />b� E <br />FIRE ALARM <br />HORN STROBE <br />P2WL <br />SYSTEM SENSOR <br />4S DEEP <br />W/ 1G RING <br />80" A.F.F. <br />TO BOTTOM <br />(3)E <br />( <br />TE <br />FIRE ALARM <br />STROBE <br />SRL <br />SYSTEM SENSOR <br />4S DEEP <br />W/ 1G RING <br />80" A.F.F. <br />TO BOTTOM <br />FIRE ALARM <br />HORN/STROBE <br />PC2RL <br />SYSTEM SENSOR <br />4S DEEP <br />W/ 1G RING <br />CEILING <br />6 <br />�c <br />FIRE ALARM <br />STROBE <br />SCRL <br />SYSTEM SENSOR <br />4S DEEP <br />W/ 1G RING <br />CEILING <br />--� <br />END -OF -LINE <br />RESISTOR <br />- <br />- <br />- <br />- <br />2 <br />BATTERY <br />2V 8AH <br />SLA1075 <br />SIEMENS <br />SYMBOLS LEGEND <br />120V DEDICATED <br />(BY OTHERS) <br />0 <br />H <br />Z <br />w <br />J 2 <br />w <br />Q <br />�O <br />O <br />Z It a ='. <br />W WQ <br />Z <br />'S S <br />S S S �p7 1S S S �7 <br />w <br />H <br />VA.., <br />v <br />A �� A IC.d a .., A .., A i� Ai ECL S2 <br />Z F <br />w rn w <br />S2-1 <br />E��E c c <br />52-2 S23 S2-0 S2-5 S2-6 S2-7 S2-8 <br />F-r <br />S 15Cd S <br />15Cd S 15Cd S 15Cd S 15Cd S 15Cd S 15Cd S 15Cd S <br />W\ N w <br />EOL S <br />/ o <br />r <br />S1-1E <br />S1-� 51-3c S1-0� S1S 516E 51-�� S18 S19 <br />� Q <br />D 115Ctl D <br />15Cd D 30Cd D 15Cd D 15Cd D 15Cd D 15Cd 30Cd 15Cd <br />LU <br />S <br />E <br />S S S S S TO OTHER <br />E E E E E SUITE <br />LL <br />AARON E. MAUS <br />NICET LEVEL III <br />CERT. #133903 EXP. 03/01 /2024 <br />Z <br />0 <br />0 <br />LL <br />Z <br />e>• <br />2 <br />IUj <br />I <br />Nr <br />N <br />(SCALE: NOT TO SCALE t <br />BY: <br />\JOB NUMBER:72123-1 J <br />1I1_=_rf L.JIHl7FtHIVI FA-01 <br />& Confidential. Coovriaht 2013 by Guardian Security Svstems. Inc. All Riahts Reserved <br />
The URL can be used to link to this page
Your browser does not support the video tag.