Laserfiche WebLink
CEILIN <br />TILE <br />J 0 m <br />Z <br />cc <br />2 (\\ ) <br />3 �Y <br />C61 <br />❑oo <br />I= <br />SK 5495 S <br />0 <br />° + + + + + + + <br />° FROM REMOTE <br />° BOOSTER POWER EOL <br />° SUPPLY <br />HORN STROBE HORN HORN <br />° STROBE STROBE STROBE <br />TYPICAL NAC CIRCUIT WIRING DIAGRAM <br />AUX OUT4 OUT3 OUT2 OUT1 TROUBLE INPUT2 INPUT <br />EOL ON LAST <br />POWER SUPPLY <br />TRIGGER FROM SK-CONTROL <br />NOTIFICATION MODULE <br />NAC CIRCUIT S1 <br />NAC CIRCUIT S2 <br />SPARE <br />" SPARE <br />SK-5495 REMOTE BOOSTER POWER SUPPLY WIRING DETAILS <br />OBE <br />TROBE <br />STROBE MOUNTING (DROP CEILI <br />HARD LID <br />CEILING <br />STROBE MOUNTING (HARD LI <br />FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION <br />Project: AVENUE DENTAL TI <br />Panel: SK05495 REMOTE BOOSTER POWER SUPPLY <br />Date: September 13, 2023 <br />Module/Device Oty Standby Total Standby Alarm Total Alarm <br />(ma) (ml (mA) (mi <br />Power Module <br />1 <br />78 <br />78 <br />0 <br />174 <br />174 <br />0 <br />A TOTAL FIRE ALARM POWER SUPPLY 78 174 <br />B Auldliary Device Current 0 0 <br />C Notification Appliance Load (Max Total /mA) 0 1242 <br />Tolal(A)= 78 Total(B)= 1416 <br />CALCULATION <br />D Total current ratings of all devices in system (line A + line B + line C) <br />78 <br />1416 <br />E Total current ratings converted to amperes (line D x .001) <br />0.078 <br />1.416 <br />F Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 15,25). <br />24 <br />Gi Multiply lines E and F Total Standby AH <br />1,872 <br />H Alarm sounding period in hours (15 mins= 0.25 hours) <br />0.25 <br />I Multiply lines E and H Total Alarm AH <br />0. 354 <br />J Add lines G and I Total Standby and Alarm AH <br />2.226 <br />K Multiply line J by 1.2 (20% extra insurance to meet desired performance) <br />2.6712 <br />12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 <br />Notification Appliance Circuit Detail <br />PROJECT: AVENUE DENTAL TI <br />Panel: SK-5495 REMOTE BOOSTER POWER SUPPLY <br />Wire Resistance 3.07 <br />Date: September 13, 2023 <br />CURRENT TOTAL= 1513.00 <br />CIRCUIT: CIRCUIT S-1 Alar. Al.r. <br />Wire Wire _1oltage, <br />TY Device Type Current <br />'1 PC2RK @115Cd 229 <br />Total Size Length <br />229 <br />at EOL <br />— PC2RL @15Cd <br />3 <br />■ <br />1 PC2RL @30Cd 116 <br />116 <br />3 SCRL @15Cd i <br />198 <br />■ <br />1 SCRL @30Cd 94 <br />94 <br />DEVICES 9 TOTAL mA- <br />910 14 300 <br />22.32 <br />9101 <br />Total Wire Resistance ( R) <br />(W L * 2) * (R/ft) <br />1.84 <br />Total Device Load, Amps <br />Voltage Drop ( E) <br />(E= I * R) <br />1.68 <br />EOL Voltage <br />CIRCUIT CIRCUIT S-2 Alarm Alarm <br />Wire Wire <br />Voltage ci;wit <br />22.32 <br />TY Device e Current <br />'3 PC2RL @15Ctl• 91 <br />Total Size Length <br />273 <br />tEOL Total <br />5 SCRL @iSCd W <br />DEVICES 8 TOTAL mA- <br />603 14 300 <br />1 22.891 <br />603 <br />Total Wire Resistance ( R ) <br />(W L * 2) * (RIft) <br />1.84 <br />Total Device Load, Amps (1) <br />Voltage Drop ( E) <br />(E= I * R) <br />1.11 <br />EOL Voltage <br />2424 E)4 <br />SYSTEM CALCULATIONS <br />AARON E. MAUS <br />NICET LEVEL III <br />CERT. #133903 EXP. 03/01 /2024 <br />0 <br />I— <br />Z <br />W <br />J 2 <br />W <br />Q ono <br />Z a �00 <br />W Q <br />Z Q� <br />Z F- -w <br />w Ir NW <br />aQ� <br />W <br />LL <br />( <br />I�JLU <br />L <br />0 <br />V <br />Z_ <br />D <br />O <br />2 <br />06 <br />Z <br />J <br />Q <br />U_ <br />L.L <br />0" <br />(SCALE: NOT TO SCALE 1 <br />BY: <br />TYPICAL WIRING AND MOUNTNG DETAILS <br />\JOB NUMBER:72123-1 J <br />& Confidential. CoDvriaht 2013 by Guardian Securitv Svstems. Inc. All Riahts Reserved \ FA-02 <br />