My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2024-10-25
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2024-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2024 11:33:02 AM
Creation date
8/5/2024 10:36:48 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- FARRINGTON <br /> AIR QUALITY SERVICES <br /> Air Handling Unit <br /> PROJECT: Ballot Facility TI DATE: 6/17/2024 <br /> LOCATION: Everett,WA CONTACT: JT Parker <br /> PROJECT#: 23-1064 <br /> SYSTEM/UNIT: AHU-01/B-05 Tested By: Eric Liles <br /> Date: 6/13/2024 <br /> Unit Data Term Box Test Data <br /> Manufacturer Trane Design Max Airflow 825 CFM <br /> Model Number VDDF Actual Max Airflow 806 CFM <br /> Serial Number R23K01740 Max Diff.SP 0.28 in.wc <br /> Box Inlet Size 10"/8" Min Design CFM 250 CFM <br /> K Factor 2.0/2.0 Actual Min Airflow 264 CFM <br /> Min Diff.SP 0.03 in.wc <br /> Design Reheat Airflow 575 CFM <br /> Actual Reheat Airflow 576 CFM <br /> Reheat Diff.SP 0.37 in.wc <br /> AHU-01/B-05 Supply Outlet Summary <br /> System/Unit Outlet Size LxW/ Instrument AK Design Prelim Final CFM %Final <br /> Type D Factor CFM CFM - <br /> Outlet-01 CD 10 Flowhood 1.00 275 275 275 100 <br /> Outlet-02 CD 10 Flowhood 1.00 275 275 275 100 <br /> Outlet-03 CD 10 Flowhood 1.00 275 275 275 100 <br /> Totals: - - - - 825 825 825 100 <br /> SYSTEM/UNIT: AHU-01/B-06 Tested By: Eric Liles <br /> Date: 6/13/2024 <br /> Unit Data Term Box Test Data <br /> Manufacturer Trane Design Max Airflow 800 CFM <br /> Model Number VDDF Actual Max Airflow 758 CFM <br /> Serial Number R23K01746 Max Diff.SP 0.64 in.wc <br /> Box Inlet Size 8"/6" Min Design CFM 240 CFM <br /> K Factor 2.0/2..0 Actual Min Airflow 250 CFM <br /> Min Diff.SP 0.07 in.wc <br /> Design Reheat Airflow 560 CFM <br /> Actual Reheat Airflow 300 CFM <br /> Reheat Diff.SP 0.36 in.wc <br /> Log: AHU-01/B-06 6/13/2024 Eric Liles Hot deck inlet size is to small for 560cfm to travel <br /> through it.Inlet size is 6".Hot deck is calibrated at <br /> 300cfm <br /> AHU-01/B-06 Supply Outlet Summary <br /> System/Unit Outlet Size LxW/ Instrument AK Design Prelim Final CFM %Final <br /> Type D Factor CFM CFM <br /> Outlet-01 CD 12" Flowhood 1.00 200 200 200 100 <br /> Outlet-02 CD 12" Flowhood 1.00 200 200 200 100 <br /> Outlet-03 CD 12" Flowhood 1.00 200 200 200 100 <br /> Outlet-04 CD 12" Flowhood 1.00 200 200 200 100 <br /> Totals: - - - - 800 800 800 100 <br /> Farrington Air Quality Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.