My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2024-10-25
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2024-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2024 11:33:02 AM
Creation date
8/5/2024 10:36:48 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FARRINGTON <br /> (, _„,.. , <br /> -A-{, AIR QUALITY SERVICES <br /> Air Handling Unit <br /> PROJECT: Ballot Facility TI DATE: 6/17/2024 <br /> LOCATION: Everett,WA CONTACT: JT Parker <br /> PROJECT#: 23-1064 <br /> SYSTEM/UNIT: AHU-01/B-19 Tested By: Eric Liles <br /> Date: 6/17/2024 <br /> Unit Data Term Box Test Data <br /> Manufacturer Trane Design Max Airflow 300 CFM <br /> Model Number VDDF Actual Max Airflow 290 CFM <br /> Serial Number R23K01763 Max Diff.SP 0.31 in.wc <br /> Box Inlet Size 06/06 Min Design CFM 90 CFM <br /> K Factor 2.15/95 Actual Min Airflow 95 CFM <br /> Min Diff.SP 0.04 in.wc <br /> Design Reheat Airflow 210 CFM <br /> Actual Reheat Airflow 215 CFM <br /> Reheat Diff.SP 0.17 in.wc <br /> AHU-01/B-19 Supply Outlet Summary <br /> System/Unit Outlet Size LxW/ Instrument AK Design Prelim Final CFM %Final <br /> Type D Factor CFM CFM <br /> Outlet-01 CD 10 Flowhood 1.00 150 150 150 100 <br /> Outlet-02 CD 10 Flowhood 1.00 150 140 140 93 <br /> Totals: - - - - 300 290 290 97 <br /> SYSTEM/UNIT: AHU-01/B-20 Tested By: Eric Liles <br /> Date: 6/17/2024 <br /> Unit Data Term Box Test Data <br /> Manufacturer Trane Design Max Airflow 450 CFM <br /> Model Number VDDF Actual Max Airflow 425 CFM <br /> Serial Number R23K01764 Max Diff.SP 0.67 in.wc <br /> Box Inlet Size 06/06 Min Design CFM 135 CFM <br /> K Factor 2.15/2.17 Actual Min Airflow 135 CFM <br /> Min Diff.SP 0.07 in.wc <br /> Design Reheat Airflow 315 CFM <br /> Actual Reheat Airflow 300 CFM <br /> Reheat Diff.SP 0.33 in.wc <br /> AHU-01/B-20 Supply Outlet Summary <br /> System/Unit Outlet Size LxW/ Instrument AK Design Prelim Final CFM %Final <br /> Type D Factor CFM CFM <br /> Outlet-01 CD 8 Flowhood 1.00 150 150 150 100 <br /> Outlet-02 CD 8 Flowhood 1.00 150 150 150 100 <br /> Outlet-03 CD 8 Flowhood 1.00 150 125 125 83 <br /> Totals: - - - - 450 425 425 94 <br /> Farrington Air Quality Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.