My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2024-10-25
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2024-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2024 11:33:02 AM
Creation date
8/5/2024 10:36:48 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:-1;'' FARRINGTON <br /> AIR QUALITY SERVICES <br /> 11 <br /> Air Handling Unit <br /> PROJECT: Ballot Facility TI DATE: 6/17/2024 <br /> LOCATION: Everett,WA CONTACT: JT Parker <br /> PROJECT#: 23-1064 <br /> SYSTEM/UNIT: AHU-01/B-23 Tested By: Eric Liles <br /> Date: 6/17/2024 <br /> Unit Data Term Box Test Data <br /> Manufacturer Trane Design Max Airflow 525 CFM <br /> Model Number VDDF Actual Max Airflow 530 CFM <br /> Serial Number R23K01758 Max Diff.SF' 0.32 in.wc <br /> Box Inlet Size 08/06 Min Design CFM 160 CFM <br /> K Factor 2.0/2.1 Actual Min Airflow 180 CFM <br /> Min Diff.SP 0.04 in.wc <br /> Design Reheat Airflow 365 CFM <br /> Actual Reheat Airflow 350 CFM <br /> Reheat Diff.SP 0.46 in.wc <br /> AHU-01/B-23 Supply Outlet Summary <br /> System/Unit Outlet Size LxW I Instrument AK Design Prelim Final CFM %Final <br /> Type D Factor CFM CFM <br /> Outlet-01 CD 10 Flowhood 1.00 175 175 175 100 <br /> Outlet-02 CD 10 Flowhood ' 1.00 175 175 175 - 100 <br /> Outlet-03 CD 10 Flowhood 1.00 175 180 180 103 <br /> Totals: - - - - 525 530 530 101 <br /> SYSTEM/UNIT: AHU-01/B-24 Tested By: Eric Liles <br /> Date: 6/17/2024 <br /> Unit Data Term Box Test Data <br /> Manufacturer Trane Design Max Airflow 525 CFM <br /> Model Number VDDF Actual Max Airflow 525 CFM <br /> Serial Number R23K01759 Max Diff.SP 0.29 in.wc <br /> Box Inlet Size 08/06 Min Design CFM 160 CFM <br /> K Factor 2.10/2.13 Actual Min Airflow 165 CFM <br /> Min Diff.SP 0.03 in.wc <br /> Design Reheat Airflow 365 CFM <br /> Actual Reheat Airflow 350 CFM <br /> Reheat Diff.SP 0.46 in.wc <br /> AHU-01/B-24 Supply Outlet Summary <br /> System/Unit Outlet Size LxW/ Instrument AK Design Prelim Final CFM %Final <br /> Type D _ Factor CFM CFM <br /> Outlet-01 CD 10 Flowhood 1.00 175 175 175 1 100 <br /> Outlet-02 CD 10 Flowhood 1.00 175 175 175 100 <br /> Outlet-03 CD 10 Flowhood 1.00 175 175 175 - 100 <br /> Totals: - - - - 525 525 525 100 <br /> Farrington Air Quality Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.