Ms. Janet Monda <br /> Architectural Werks, Inc. <br /> Plan Check Number: B2302-096, First Building Review <br /> March 23, 2023 <br /> 17. The construction drawings should specify that the parking includes a minimum vehicle EV <br /> infrastructure of 10% charging spaces and 10% future spaces per IBC Section 429.4 Items 1 <br /> and 2, respectively. See IBC Section 429.2. <br /> 18. Continuing with the previous comment, EV infrastructure is required to be provided for the <br /> accessible spaces per IBC Section 429.5. <br /> Structural <br /> General: <br /> 1. The construction drawings should include a section with the following note and listing work to <br /> be reviewed and approved by the EOR prior to construction. Review and approval by the EOR <br /> will be deemed to satisfy the requirements of IBC Sections 107.3 and 107.3.4.1. This work will <br /> not require additional review by the City of Everett as it has been reviewed in principle on the <br /> issued construction drawing; final review responsibility is deferred to the EOR. Alternatively, <br /> the applicant is required to identify and submit the items listed below under separate permit <br /> applications for review and approval prior to construction, or they must be included in the <br /> current submittal documents. Work qualifying as shop drawings may be listed separately per <br /> the Exception of IBC Section 107.1. <br /> "Submittal documents for the following components and systems are required to be reviewed <br /> and approved by the Engineer-of-Record(EOR)in accordance with IBCSection 107.3. The <br /> submittals shall be prepared by a professional engineer(s)licensed in the state of Washington. <br /> The EOR shall perform a comprehensive review for conformance with the approved construction <br /> drawings and the referenced buildings codes The EOR shall mark the submittals as approved <br /> for construction prior to fabrication and erection by the manufacturer(s)and contractor(s)." <br /> Based on a review of the drawings, work to be listed should include but is not limited to: <br /> a. Engineered roof trusses. <br /> b. Elevator system. <br /> 2. Structural and geotechnical special inspections are required for this project. A table of the <br /> required inspections is provided in the"Quality Assurance's section of the General Structural <br /> Notes on Sheet S000. The table should be revised to specify the types and extent of each <br /> inspection (e.g., continuous, periodic). See IBC Sections 107.1 and 1704.3.1. <br /> 3. Continuing with the previous comment, the table of special inspections appears to be <br /> incomplete. The table should be revised by adding additional inspections for steel and wood <br /> construction. See IBC Sections 1705.2 and 1705.12.2. <br /> 4. The General Structural Notes should include requirements for steel construction. See IBC <br /> Sections 107.2.1 and Chapter 22. <br /> 3200 Cedar Street © 425.257.8810 0everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 4 of 7 <br />