My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8531 EVERGREEN WAY COMMUNITY HEALTH CENTER 2025-05-28
>
Address Records
>
EVERGREEN WAY
>
8531
>
COMMUNITY HEALTH CENTER
>
8531 EVERGREEN WAY COMMUNITY HEALTH CENTER 2025-05-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2025 1:23:07 PM
Creation date
8/27/2024 11:52:36 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8531
Tenant Name
COMMUNITY HEALTH CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
644
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Name <br /> May 1, 2023 <br /> Page 2 <br /> 4. Comment: The following comments should be addressed for the handrails per IBC section 1014: <br /> a. The Code Plans on sheet A0.2 do not appear to show the handrails correctly or consistently with <br /> the plans on sheets A2.1 and A2.2. <br /> Response: See revised sheets A0.2,A2.1 &A2.2., stair tread is flush with floor system. <br /> b. Extensions should be shown at the top of the southwest stairway on sheet A2.2. <br /> Response: See revised sheet A2.2., stair tread is flush with floor system. <br /> c. The bottom extension in section 2/A4.3 should be sloped. <br /> Response: Noted, See revised section 2/A4.3. <br /> d. The handrails height in section 2/A4.4 should be measured from the stair nosing, not the midpoint <br /> of the stair. Note that this dimension is correctly shown in detail 5/A6.2; it is recommended that <br /> the dimension on the section be deleted. <br /> Response: Noted, See revised section 1/A4.3, deleted dimension, <br /> e. detail 9/A6.2 should show the bottom extension as sloped and specify a minimum length of one <br /> stair tread past the bottom nosing. <br /> Response: Noted, See revised detail 6/A6.2. <br /> f. A detail for the continuous handrail condition wrapping around center walls at landings should be <br /> included in the drawings. <br /> Response: See revised sheets A0.2,A2.1 &A2.2. <br /> 5. Comment: The southwest exterior stairway in Elevation 2/A4.2 should specify a maximum landing <br /> height above the adjacent grade not to exceed 30 inches. Alternatively, a guard should be provided. <br /> See IBC section 1015.2. <br /> Response: Noted, see revised section 2/A4.2, added guardrail. <br /> 6. Comment: The exit sign on sheet A3.1 in the southwest stairway above door 1AB should be relocated <br /> to the Corridor 112 side of the door. See IBC section 1013.1. <br /> Response: Noted, See revised sheet A3.1. <br /> 7. Comment: The second story requires two means of egress per IBC Table 1006.3.3(2). The First Floor <br /> Ceiling Plan on sheet A3.1 should specify exterior emergency egress lighting. See IBC section <br /> 1008.3.2 Item 5. <br /> Response: See sheet A3.1, added note at exterior wall mounted fixture L-10 at northeast <br /> stairwell, reads; "WALL MOUNT FIXTURE W/EMERGENCY BACK-UP." See <br /> exterior recessed light fixture w/emergency back-up L-7E at southwest <br /> stairwell. <br /> 8. Comment: The Ceiling Plans on sheets A3.1 and A3.2 should specify minimum 90-minute back-up <br /> power for the emergency egress lights and exit signs. See IBC sections 1008.3.4 and 1013.6.3. <br /> Response: See sheetA0,3, reflected ceiling plan legend, added note reads: "EMERGENCY <br /> LIGHTING:MINIMUM BATTERY BACK-UP TIME OF 90 MIN." <br /> Accessibility: <br /> 9. Comment: The Door Schedule on sheet A9.1 should specify where door closers are intended. Several <br /> doors may not be allowed to include closers due to inadequate clearances, including but not limited to <br /> Doors 103A and 217A. See IBC section 1101.2 and ICC A117.1-09 Figure 404.2.3.2. <br /> Response: See revised sheet A9.1 Door Schedule, added keyed remark#8, Keyed Remark <br /> reads; "DOOR CLOSURE NOT TO BE INSTALLED." Added keyed remote #8 to <br /> Door 103A and 217A remarks. <br /> Cc: 4d 0-5) <br />
The URL can be used to link to this page
Your browser does not support the video tag.