My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8531 EVERGREEN WAY COMMUNITY HEALTH CENTER 2025-05-28
>
Address Records
>
EVERGREEN WAY
>
8531
>
COMMUNITY HEALTH CENTER
>
8531 EVERGREEN WAY COMMUNITY HEALTH CENTER 2025-05-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2025 1:23:07 PM
Creation date
8/27/2024 11:52:36 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8531
Tenant Name
COMMUNITY HEALTH CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
644
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Name <br /> May 1, 2023 <br /> Page 3 <br /> 10. Comment: detail 1/A7.1 should specify pipe protection. See IBC section 1101.2 and ICC A117.1-09 <br /> section 606.6. <br /> Response: Noted, see interior elevation 1/A7.1, added annotation reads: "PIPE <br /> PROTECTION." <br /> 11. Comment: The solid blocking notes in details on sheet A7.1 should specify that the blocking can <br /> support a minimum 250-LB load. See IBC section 1101.2 and ICC A117.1-09 section 609.8. <br /> Response: Noted, see interior elevation 2/A7.1, added note, reads: "PROVIDE SOLID <br /> BLOCKING FOR MINIMUM 250 LB. LOAD AT ALL TOILET ACCESSORIES," <br /> 12. Comment: The shower in Room 114 should provide a minimum 48-inch clearance from the control <br /> wall surface. The Floor Plan on sheet A2.1 appears to show the clearance from the room wall surface, <br /> not the shower wall surface. Both the plan and detail 4/A7.2 appear to provide less than the required <br /> clearance due to encroachment by the sink. The design should be revised. <br /> Response: See revised floor plan 1/A2.1 and revised interior elevation 4/A7,2. <br /> Energy: <br /> 13. Comment: detail 4/A5.1 specifies rigid insulation on the foundation exterior extending to the top of the <br /> footing. The insulation is required to extend 24 inches horizontally from the foundation. See WSEC <br /> section C402.2.6 and Table C402.1.3. <br /> Response: See revised sheets, A4.1,A4.2,A4.3, and A4,4, see revised details 4/A5,1, <br /> 5/A5.1, 6/A5,1, 2/A5.2, 6/A5.2, & 17/A5.2, illustrating 24 inches of rigid <br /> insulation horizontally from the foundation. <br /> 14. Comment: The project is required to include a schedule of energy credits per WSEC section C406.1. <br /> Response: See mechanical and interior lighting compliance summary reports included in <br /> deferred mechanical and electrical permit applications. 7 total energy credits <br /> Miscellaneous: <br /> 15. Comment: The building elevations and sections, and detail 4/A5.1 do not appear to provide the <br /> minimum required clearance of wood framed construction above the adjacent grade. detail 1/S302 <br /> specifies a 6-inch clearance. The construction drawings should specify a minimum 8-inch or 2-inch <br /> clearance to loose soil or hard surfaces, respectively. See IBC sections 2304.12.1.2 and 2304.12.1.5. <br /> Response: See revised sheets, A4.1,A4.2,A4.3,A4.4,A5.1, see revised details 4/A5.1, <br /> 5/A5.1, 6/A5,1, <br /> Response: See Structural Plan Review Response Letter, <br /> 16. Comment: The roof is anticipated to potentially support mechanical equipment. The following <br /> comments should be addressed: <br /> a. The approximate locations of equipment should be shown in the roof plans. See IBC section <br /> 107.2.1. <br /> Response: See sheet A2.3, VRF cooling tower shown on roof plan. <br /> Response: See Structural Plan Review Response Letter. <br /> b. The estimate weights of equipment should be specified in construction drawings. See IBC section <br /> 1603.1.8. <br /> Response: See Structural Plan Review Response Letter. <br /> c. The roof may require taller parapets or fall-protection systems depending on the equipment <br /> locations. The drawings may need to be revised. details for fall-protection systems should be <br /> Cc: 4d .(;"--- <br />