<br />CHIC ADMIN EXPANSION
<br />8531 EVERGREEN WAY, EVERETT, WA
<br />i
<br />\ N
<br />\ 20 10 0 20 40
<br />\ SCALE IN FEET
<br />/ 1 "=20'
<br />\
<br />GENERAL BRH NOTES:
<br />1. EXISTING UTILITIES AND UNDERGROUND STRUCTURES SHOWN ON THE PLAN ARE BASED UPON THE BEST AVAILABLE PUBLIC RECORDS AND/OR PRIVATE RECORDS AS SUPPUED BY THE PROJECT OWNER
<br />AND/OR DATA OBTAINED VERBALLY FROM OWNERS OR OFFICIALS ASSOCIATED WITH THE PARTICULAR UTILITY. NEITHER THE OWNER NOR THE ENGINEER GUARANTEE THE ACCURACY OR COMPLETENESS
<br />OF THIS INFORMATION AND ASSUME NO RESPONSIBILITY FOR IMPROPER LOCA11ONS OR FAILURE TO SHOW UTILITY LOCATIONS ON THE CONSTRUCTION PLANS. OTHER UNDERGROUND FACILITIES NOT SHOWN
<br />ON THE DRAWINGS MAY BE ENCOUNTERED DURING THE COURSE OF THE WORK. ALL INVERT ELEVATIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
<br />2. IF CHANGED CONDITIONS ARE ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PROMPTLY OF (1) PREEXISTING SUBSURFACE CONDITIONS DIFFERING FROM THOSE INDICATED IN THE PLANS,
<br />OR (2) PREEXISTING UNKNOWN SUBSURFACE CONDITIONS, OF AN UNUSUAL NATURE, DIFFERING MATERIALLY FROM THOSE ORDINARILY ENCOUNTERED AND GENERALLY RECOGNIZED AS INHERENT IN WORK
<br />OF THE CHARACTER PROVIDED FOR IN THE CONTRACT. THE CONTRACTOR AND/OR THE OWNER SHALL MAKE NO CLAIMS TO THE ENGINEER FOR RECOMPENSATION FOR EXTRA WORK RESULTING FROM
<br />CHANGED CONDITIONS UNLESS THE ENGINEER HAS APPROVED THE WORK IN WRITING. (WSDOT SECTION 1-04.7).
<br />3. THE CONTRACTOR SHALL CALL THE UTILITIES UNDERGROUND LOCATION CENTER FOR FIELD LOCATION OF ALL UTILITIES AND SHALL NOT BEGIN EXCAVATION UNTIL ALL KNOWN UNDERGROUND FACILITIES IN
<br />THE VICINITY OF THE PROPOSED WORK HAVE BEEN LOCATED AND MARKED. IF THE UTILITY IS NOT A SUBSCRIBER OF THE UNDERGROUND LOCATION CENTER THEN THE CONTRACTOR SHALL GIVE
<br />INDIVIDUAL NOTICE TO THAT UTILITY. (WSDOT SECTION 1-07.17 APWA SUPPLEMENT).
<br />4. THE CONTRACTOR SHALL TAKE REASONABLE PRECAUTIONS AND EXERCISE SOUND ENGINEERING AND CONSTRUCTION PRACTICES IN CONDUCTING THE WORK. THE CONTRACTOR SHALL PROTECT EXISTING
<br />PUBLIC AND PRIVATE UTILITIES FROM DAMAGE DURING CONSTRUCTION. IF EXISTING U1ILITIES ARE DAMAGED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND THE ENGINEER. THE
<br />CONTRACTOR SHALL RESTORE THE UTILITY TO ITS EXISTING CONDITION. (WSDOT SECTION 1-07.17 APWA SUPPLEMENT). THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF
<br />CONSTRUCTION FOR DESIGNS SHOWN ON THESE PLANS.
<br />5. WHERE THE PLANS CALL FOR UTILITIES TO BE RELOCATED BY OTHERS, THE CONTRACTOR SHALL NOTIFY THE UTILITY COMPANY AND COORDINATE HIS WORK SO AS TO AVOID CONFLICTS.
<br />6. ALL EXCAVATION, TRENCHING, SUBGRADE PREPARATION, FILL PLACEMENT AND COMPACTION AND ALL SOIL WORK IN GENERAL SHALL BE CONDUCTED IN COMPLIANCE WITH THE RECOMMENDATIONS OF THE
<br />PROJECT SOIL ENGINEER AND THE CURRENT GEOTECHNICAL ENGINEERING REPORT.
<br />7. ENGINEERING DESIGN AND APPROVAL FOR STRUCTURES SUCH AS WALLS AND VAULTS MUST BE PREPARED BY THE APPROPRIATE PROFESSIONAL ENGINEER AND IS NOT A PART OF THESE PLANS.
<br />8. CONTRACTOR SHALL BE RESPONSIBLE FOR HIRING PROFESSIONAL LAND SURVEYOR TO REFERENCE EXISTING MONUMENTS ON OR ADJOINING SITE PREVIOUS TO DEMOLITION OR CONSTRUCTION AND TO BE
<br />RE-ESTABLISH SAID POINTS AT PROJECT COMPLETION. THIS RE-ESTABLISHMENT SHALL BE DOCUMENTED BY RECORD OF SURVEY OR CORNER RECORD AS DESCRIBED IN W.A.C. 332-120.
<br />Permit #: PW2302-011
<br />APPROVED Site Address: 8531 Evergreen Way
<br />PUBLIC WORKS DEPARTMENT Owner: CHIC of Snohomish County
<br />BY: TNewport Application Date: 02/22/2023
<br />DATE: 08/22/2023 Description: Site Work for CHIC
<br />CITY OF EVERETT REVIEWED FOR PERMIT
<br />Review Status: Approved as Noted
<br />Review Date: 08/22/2023
<br />STORM DRAINAGE NOTES:
<br />1. NO PART OF THE DRAINAGE SYSTEM SHALL BE COVERED, CONCEALED, OR PUT INTO USE UNTIL IT
<br />HAS BEEN INSPECTED, TESTED, AND ACCEPTED BY THE CITY OF EVERETT.
<br />2. ALL WORK AND MATERIAL SHALL CONFORM TO THE CITY OF EVERETT DESIGN AND CONSTRUCTION
<br />STANDARDS AND SPECIFICATIONS AND THE WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD,
<br />BRIDGE, AND MUNICIPAL CONSTRUCTION (CURRENT EDITION).
<br />3. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM AVAILABLE RECORDS
<br />AND ARE SHOWN FOR CONVENIENCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF
<br />LOCA11ONS AND TO AVOID DAMAGE TO ANY ADDITIONAL UTILITIES SHOWN. IF CONFLICTS WITH
<br />EXISTING UTILITIES ARISE DURING CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS
<br />INSPECTOR AND ANY CHANGES REQUIRED SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO
<br />COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT.
<br />4. ALL STORM SYSTEMS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN EASEMENTS MUST BE STAKED BY
<br />SURVEY FOR LINE AND GRADE PRIOR TO STARTING CONSTRUCTION.
<br />5. ALL CATCH BASIN GRATES MUST BE STENCILED OR STAMPED 'DUMP NO WASTE, DRAINS TO STREAM,
<br />LAKE, RIVER, PUGET SOUND, OR WETLAND." CHOOSE APPROPRIATE FEATURE FOR THE PROJECT
<br />6. DESIGN SHALL COMPLY WITH THE EVERETT MUNICIPAL CODE (EMC), CITY ADOPTED STORMWATER
<br />MANAGEMENT MANUAL, POLICIES AND CRITERIA SET FORTH IN THE CITY OF EVERETT'S DESIGN AND
<br />CONSTRUCTION STANDARDS & SPECIFICATIONS.
<br />SANITARY SEWER NOTES:
<br />1. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETT STANDARDS AND WSDOT/APWA
<br />STANDARD SPECIFICATIONS.
<br />2. NO PART OF THE SANITARY SEWER SYSTEM SHALL BE COVERED, CONCEALED OR PUT INTO USE UNTIL
<br />IT HAS BEEN TESTED, INSPECTED, AND APPROVED BY THE CITY INSPECTOR.
<br />3. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM AVAILABLE RECORDS
<br />AND ARE SHOWN FOR CONVENIENCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF
<br />LOCATIONS AND TO AVOID DAMAGE TO ANY ADDITIONAL UTILITIES NOT SHOWN. IF CONFLICTS WITH
<br />EXISTING UTILITIES ARISE DURING CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS
<br />INSPECTOR AND ANY CHANGES REQUIRED SHALL E APPROVED BY THE CITY ENGINEER PRIOR TO
<br />COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT.'
<br />4. ALL SEWER MAIN EXTENSIONS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN EASEMENTS MUST BE
<br />STAKED BY SURVEY OR LINE AND GRADE PRIOR TO STARTING CONSTRUCTION.
<br />WATER PLAN NOTES:
<br />1. NO CONNEC11ON TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY MEANS OF AN APPROVED
<br />BACKFLOW PREVENTION DEVICE PRIOR TO SATISFACTORY FLUSHING, TESTING, DISINFECTION, AND
<br />RECEIPT OF SATISFACTORY BACTERIOLOGICAL TEST RESULTS.
<br />2. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL BE MADE BY THE PUBLIC WORKS DEPARTMENT
<br />AT THE DEVELOPER'S EXPENSE. THE PUBUC WORKS DEPARTMENT SHALL BE GIVEN AT LEAST 5
<br />BUSINESS DAYS NOTICE FOR EACH CONNECTION. THE PUBLIC WORKS DEPARTMENT SHALL
<br />THEREAFTER DETERMINE THE DATE AND TIME AT WHICH THE CONNECTION SHALL BE MADE.
<br />3. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT STANDARDS.
<br />4. A PRE -CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR TO THE START OF
<br />CONSTRUCTION. THE CITY OF EVERETT PUBLIC WORKS CONSTRUCTION DIVISION MUST BE NOTIFIED AT
<br />LEAST 24 HOURS PRIOR TO COMMENCEMENT OF CONSTRUCTION.
<br />5. THE DEVELOPER OR THE DEVELOPERS AUTHORIZED AGENT SHALL NOTIFY THE PUBLIC WORKS
<br />DEPARTMENT OF A PERSON WHO CAN BE CONTACTED REGARDING PROBLEMS DURING CONSTRUCTION
<br />ON A 24 HOUR BASIS.
<br />6. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VERTICAL SEPARATION BETWEEN
<br />POTABLE AND NON -POTABLE CONVEYANCE SYSTEMS.
<br />7. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBLIC WORKS DEPARTMENT PERSONNEL
<br />ONLY. ALL VALVES, NEW AND EXISTING, SHALL BE ACCESSIBLE AT ALL TIMES.
<br />.m ..:, s26 8
<br />SITE
<br />Everette
<br />3 ea
<br />1011 s1 sE
<br />SHEET INDEX:
<br />C1.0 COVER SHEET AND NOTES
<br />C2.0 TESC PLAN
<br />C2.1 TESC DETAILS
<br />C3.0 GRADING AND DRAINAGE
<br />C3.1 SECTIONS AND DETAILS
<br />T CONTA
<br />OWNER:
<br />COMMUNITY HEALTH CENTER OF SNOHOMISH COUNTY
<br />8609 EVERGREEN WAY
<br />EVERETT, WA 98208
<br />PH: (425) 789-3723
<br />BUSH ROED & HITCHINGS
<br />15400 SE 30TH PL STE 100
<br />BELLEVUE, WA 98007
<br />CONTACT: TED DIMOF, P.E.
<br />tedd®brhinc.com
<br />PH: (206) 323-4144
<br />SURVEYOR:
<br />D.R. STRONG CONSULTING ENGINEERS
<br />620 7TH AVE
<br />KIRKLAND, WA 98033
<br />PH: (425) 827-3063
<br />ARCHITECT:
<br />ARCHIECTURAL WERKS, INC.
<br />11416 98TH AVE NE, STE 200
<br />KIRKLAND, WA 98033
<br />PH: (425) 823-2244
<br />CAUTION
<br />0
<br />UNDERGROUND !UTILITIES
<br />K now what's DORM.
<br />Callbdony0oft
<br />CONTRACTOR TO VERIFY
<br />EXACT LOCATION AND DEPTH
<br />0 x NIT H Oflwl , RB HDP TFD
<br />4, BUSH, ROED & HITCHINGS, INC. COVER SHEET AND NOTES y,O1e /
<br />N _ °° Fc" 5 4L` LAND SURVEYORS & CIVIL ENGINEERS CHIC ADMIN EXPANSION AS SHOWN O8/18/23
<br />SEAL
<br />n � vi` R 9eu24 3 PUBLIC WORKS COMMENTS 8/18/23 15400 BE 30TH PL, STE 100 (206) 323-4144 2022034
<br />a �gSI'ISI � ` �'ONA�gacJ 2 PUBLIC WORKS COMMENTS 7/07/23 BRN 98007- 54 Washington 1-800-935-0508
<br />x i arr coMMBNrs a/ia/z3 98007-6546 WWW.BRHINQCOM
<br />EVERETT SNOHOMISH COUNTY WASHINGTON C1 O
<br />V NO REVISION DATE