Laserfiche WebLink
(1110 AWG THHN/THWN-2,CU.,BLACK(ill 13.3 A AC (1) 10 AWG THHN/THWN-2,CU.,BLACK(Ll) MAX 13.3 A A( (1) 10 AWG THHN/THWN 2.CU.,BLACK(LI) MAX 13.3 A AC 11) 12.2 TC-ER,TI4HN/THWN-2,CU. MAX 13.3 A AC <br /> 15 (1) 10 AWG THNN/THWN-2,CU.,RED(1.2) 240 V AC (1) 10 AWG THHN/THWN-2,CU_,RED(L 2) 240 V AC 2 (1) 10 AWG THHN/THWN•2.CU.,RED(1-2) 240 V AC 11) 6 AWG BARE,CU(EGC) 240 V AC <br /> (1) 10 AWG THHN/THWN-2,CU.,WHITE(N) (1) 10 AWG THHN/THWN-2,CU.,GREEN(EGC) (1) 10 AWG THHN/THWN-1,CU.,GREEN(EGC) 1 <br /> (1) 10 AWG THHN/THWN-2,CU.,GREEN(EGC) OR 10-2 UF-8 WIG,THHN/THWN-2,SOLID CU. OR 10.2 OF-B WIG(OR NM-B),THHN/THWN-2,SOLID CU. <br /> 1 3/4 INCH EMT EXTERIOR (1) 3/4 INCH EMT EXTERIOR (1) 3/4 INCH EMT(Not Required for UF-11 or NM-11 Cable) EXTERIOR EXTERIOR BLUE RAVEN <br /> 1403 N. Research Way <br /> Orem, UT 84097 <br /> 800.377.4480 <br /> W W W.BLUERAVENSOLAR.COM <br /> DESIGNER NOTES: ELECTRICAL NOTES: CONFIDENTIAL-THE INFORMATION <br /> HEREIN CONTAINED SHALL NOT BE <br /> LOAD SIDE BREAKER IN MSP.INTERIOR POI. ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. USED FOR THE BENEFIT OF ANYONE <br /> THIN TWO 20A 1 POLE BREAKERS INTO A 20A/20A DUPLEX BREAKER. EXCEPT BLUE RAVEN SOLAR NOR <br /> SHALL IT BE DISCLOSED IN WHOLE OR <br /> IN PART TO OTHERS OUTSIDE <br /> RECIPIENTS ORGANIZATION,EXCEPT <br /> ENPHASE IQ COMBINER 4 IN CONNECTION WITH THE SALE AND <br /> (E)125A MAIN SERVICE PANEL X-IQ-AM1-240-4 USE OF THE RESPECTIVE EQUIPMENT, <br /> (E)125A/2P MAIN BREAKER (SOLAR LOAD ONLY) WITHOUT THE WRITTEN PERMISSION <br /> OF BLUE RAVEN SOLAR LLC. <br /> PV AC DISCONNECT <br /> (E)125A/2P NON-FUSED <br /> L1 LOCKABLE,VISIBLE OPEN <br /> L2 30A,240V,2-POLE (11)QCeIIs Q.PEAK DUO BLK ML-G10+A 400 NABCEP <br /> N <br /> UL 1703 COMPLIANT <br /> (E)LOADS *PV BREAKER TO BE LOCATED ENVOY (11) Enphase IQ8A-72-2-US CERTIFIED <br /> 4y, 10— AT OPPOSITE END OF BUSSING 15A g2P UL 1741 COMPLIANT <br /> FROM MAIN BREAKER 4"x4"x4"PVC JB-1 EZ SOLAR <br /> �EN JUNCTION BOX JUNCTION BOX PV INSTALLATION <br /> (N)20A/2P <br /> L L, (N)20A L, F JB ��, JB-1 �, _ _ (1) CIRCUIT OF PROFESSIONAL <br /> Lz L2 Lz 1 11 1 Lz I il I Lz I Scott Gurney <br /> NEGC EG N — r--- EGC _EGC I--_EGC _ = 11 MODULES #PV-011719-015866 <br /> --------------------------------------- <br /> ----------------------- <br /> CONTRACTOR: <br /> 120/240 VAC N I J 3 2 1 <br /> 60HZ I *JUNCTION BOX BRS FIELD OPS <br /> 1 PHASE I <br /> TO UTILITY OPTIONAL IF OF-B 800-377-4480 <br /> 1 <br /> GRID 1 CABLE USED FOR <br /> G J ENTIRE HOMERUN <br /> U <br /> Z CD <br /> (E)GROUNDING <br /> ELECTRODE(S) • O 00 <br /> I Q O C <br /> O M <br /> is � L.ZRr 271A � <br /> N,n — <br /> O 3 Cl) Cl) <br /> SANGAMO ELECTRIC = E <br /> 1 \ ' �• ' •'. 1t LUcv� � HH <br /> ��1�W W 8 r 0 L 0)� � >_ >_ <br /> �o�W 2023 .05 .2 8 �2 2 9 8g N o N w <br /> � ) 7 � � 00 V U <br /> 54• 3 4 r 34 7 7 4 _ C) CLrnW Q � <br /> a 3 08:06:00 • K1-°'""TT""U"S 1 DRAWING BY: <br /> 4 s TA 72Kh •, Brendan Fillmore <br /> •O4► ,� 54072 •CL P <br /> O —O6'OO' <br /> S. <br /> PUD DISNOMOMESMCo. 1 - <br /> 1"0• r PLOT DATE: <br /> 'rSlOHpL�G 25752 <br /> 4 May 17, 2023 <br /> ,..c. r.I <br /> �6�5 Z� <br /> INTERCONNECTION NOTES ;„ 'r+'W PROJECT NUMBER: <br /> 705.12(8)(3)THE FOLLOWING METHOD(S)SHALL BE USED TO <br /> DETERMINE THE RATINGS OF BUSBARS: (2)WHERE TWO SOURCES, 764787 <br /> ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER <br /> SHEET NAME: <br /> SOURCE,ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT / <br /> CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE y ELECTRICAL <br /> POWER-SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF <br /> THE OVERCURRENT DEVICE PROTECTING THE BUS BAR SHALL NOT REVISION: PAGE NUMBER: <br /> EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR. UTILITY COMPANY: Snohomish County Public Utilities District (PUD) PERMIT ISSUER: City of Everett 0 PV5 <br />