My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5316 ROCKEFELLER AVE 2024-09-19
>
Address Records
>
ROCKEFELLER AVE
>
5316
>
5316 ROCKEFELLER AVE 2024-09-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2024 8:19:35 AM
Creation date
8/29/2024 10:19:09 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
5316
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STANDARD LABELS ADDITIONAL LABELS - <br /> LABEL 1 LABEL 8 BLUE RAVEN <br /> WARNINGFOR PV SYSTEM DISCONNECTING MEANS WHERE THE O WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br /> LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE LOCATION OF ALL ELECTRIC POWER SOURCE <br /> ELECTRIC SHOCK HAZARD OPEN POSITION. MAIN DISTRIBUTION UTILITY DISCONNECT(S) DISCONNECTING MEANS ON OR IN THE PREMISES 1403 N. Research Way <br /> (2017 NEC 690.13(8)1 POWER TO THIS BUILDING IS ALSO SUPPLIED SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT Orem, UT 84097 <br /> TERMINALS ON THE LINE AND (2020 NEC 690.13(8)1 FROM A ROOF MOUNTED SOLAR ARRAY WITH LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> LOAD SIDES MAY BE ENERGIZED A RAPID SHUTDOWN DISCONNECTING MEANS DISCONNECT(S)FOR ALL ELECTRIC POWER 800.377.4480 <br /> IN THE OPEN POSITION GROUPED AND LABELED WITHIN LINE OF SITE PRODUCTION SOURCES CAPABLE OF BEING WWW.BLUERAVENSOLAR.COM <br /> AND 10 FT OF THIS LOCATION INTERCONNECTED. CONFIDENTIAL-THE INFORMATION <br /> [2017 NEC 705.10] HEREIN CONTAINED SHALL NOT BE <br /> [2020 NEC 705.10] USED FOR THE BENEFIT OF ANYONE <br /> LABEL 2 EXCEPT BLUE RAVEN SOLAR NOR <br /> PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR <br /> THE DISCONNECTING MEANS AS A POWER SOURCE LABEL 9 IN PART TO OTHERS OUTSIDE <br /> I AC DISCONNECTI AND WITH THE RATED AC OUTPUT CURRENT AND THE ! WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE RECIPIENTS ORGANIZATION,EXCEPT <br /> NOMINAL OPERATING AC VOLTAGE. LOCATION OF ALL ELECTRIC POWER SOURCE IN CONNECTION WITH THE SALE AND <br /> (2017 NEC 690.54] USE OF THE RESPECTIVE EQUIPMENT, <br /> RATED AC OUTPUT CURRENT 25.41 A POWER TO THIS BUILDING IS ALSO DISCONNECTING MEANS ON OR IN THE PREMISES WITHOUT THE WRITTEN PERMISSION <br /> (2020 NEC 690.541 SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT OF BLUE RAVEN SOLAR LLC. <br /> NOMINAL OPERATING AC VOLTAGE 240 V SUPPLIED FROM MAIN DISTRIBUTION LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> UTILITY DISCONNECT LOCATED DISCONNECT(S)FOR ALL ELECTRIC POWER <br /> PRODUCTION SOURCES CAPABLE OF BEING /� <br /> INTERCONNECTED. NABCEP <br /> IAWARNING LABEL3 [2017 NEC 705.10] <br /> IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL [2020 NEC 705.10] CERTIFIED <br /> ANYWHERE THAT IS POWERED BY BOTH THE UTILITY <br /> DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL <br /> AND SUBPANELS. PV INSTALLATION <br /> (2017 NEC 705.12(8)(3)] LABEL EN PROFESSIONAL <br /> SOURCES: UTILITY GRID AND (2020 NEC 705.12(8)(3)] ! WARNING PERMANENT PLAQUE DIRECTORY TO BE <br /> PV SOLAR ELECTRIC SYSTEM LOCATED AT MAIN SERVVICE EQUIPMENT DENOTING Scott Gurney <br /> POWER TO THIS BUILDING IS ALSO SUPPLIED THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 <br /> FROM A ROOF MOUNTED SOLAR ARRAY.SOLAR DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br /> SHUTDOWN DISCONNECTING SWITCH IS NOT CONTRACTOR: <br /> ARRAY RAPID SHUTDOWN DISCONNECT IS GROUPED AND WITHIN LINE OF SITE OF MAIN <br /> WARNING LABEL 4 BRS FIELD OPS <br /> APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT LOCATED OUTSIDE NEXT TO THE UTILITY METERJSERVICE DISCONNECTING MEANS. <br /> r'"w <br /> TO THE BACK-FED BREAKER FROM THE POWER (2017 NEC 705.10 AND 690.56(C)(1)(a)] W 8 2023 .05 . 1 800-377-4480 <br /> POWER SOURCE OUTPUT CONNECTION SOURCE. [2020 NEC 705.10 AND 690.56(C)] Ate_ <br /> DO NOT RELOCATE [2017 NEC 705.12(8)(2)(3)(b)] �,Q` �p1?WAS c��� <br /> (2020 NEC 705.12(8)(3)(2)] <br /> THIS OVERCURRENTLABEL 11 y� OZ <br /> DEVICE ! WARNING PERMANENT PLAQUE OR DIRECTORY TO BE a • U <br /> LOCATED AT AC COMBINER PANEL. •/ •4 5 Z Q Q <br /> PHOTOVOLTAIC SYSTEM [2017 NEC 110.21(8)] .o <br /> OWARNING LABELS [2020 NEC 110.21(8)] <br /> I APPLY TO THE PV COMBINER BOX COMBINER PANEL �0� -is C) <br /> � ' ' O O Y <br /> (2017 NEC 705.12(B)(2)(3)(c)] FS ! G O 0 0 Q O O <br /> DO NOT ADD LOADS S <br /> (2020 NEC 705.12(8)(3)(3)] ONAL <br /> THIS EQUIPMENT FED BY MULTIPLE a/ > C: CD 0C) <br /> W W <br /> SOURCES.TOTAL RATING OF ALL O Co O <br /> OVERCURRENT DEVICES,EXCLUDING I.L. i — N N <br /> MAIN SUPPLY OVERCURRENT SUBPANEL Z N Co <br /> UTILITY MAIN IF INTERCONNECTION AC PV PV COMBINER <br /> DEVICE,SHALL NOT EXCEED ( — N '- <br /> AMPACITY OF BUSBAR. METER SERVICE PANEL IS MADE HERE) DISCONNECT METER BOX W Y V) W W <br /> 00 00 00 00 o _ 0 U) U) <br /> LEL <br /> SOLAR PV SYSTEM EQUIPPED BUILc <br /> DINGS WITH PV SYSTEMS SHALL HAVE A E Cl) <br /> WITH RAPID SHUTDOWN PERMANENT LABEL LOCATED AT EACH SERVICE O O O O O O O = Co <br /> M > V U <br /> EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS V Q Lo Lij Q Q <br /> TURN RAPID SHUTDOWN ARE CONNECTED OR AT AN APPROVED READILY <br /> "O FI POSITION TO TO THE VISIBLE LOCATION AND SHALL INDICATE THE LOCATION O IF BREAKER O <br /> OR PLACARD 11 <br /> WN PV SYSTEM OF RAPID SHUTDOWN INITIATION DEVICES. IS USED DRAWING BY: <br /> SHUT DO <br /> 0 <br /> AND REDUCE (2017 NEC 690.56(C)(1)(a)] <br /> SHOCK HAZARD <br /> IN THE ARRAY [2020 NEC 690.56(C)] O OR 10 Brendan Fillmore <br /> OR PLACARD PLOT DATE: <br /> RAPID SHUTDOWN LABEL 7 May 16 2023 <br /> SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT <br /> SWITCH FOR SWITCH <br /> (2017 NEC 690.56(C)(3)] PROJECT NUMBER: <br /> SOLAR PV SYSTEM (2020 NEC 690.56(C)(2)] <br /> 767549 <br /> LABELING NOTES SHEET NAME: <br /> 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT LABELS <br /> REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL <br /> 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED <br /> 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: <br /> 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE 0 PV7 <br /> HANDWRITTEN[NEC 110.211 DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />
The URL can be used to link to this page
Your browser does not support the video tag.