My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1403 ROCKEFELLER AVE 2024-10-25
>
Address Records
>
ROCKEFELLER AVE
>
1403
>
1403 ROCKEFELLER AVE 2024-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2024 9:57:24 AM
Creation date
9/6/2024 1:51:19 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
1403
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Option 2B Rain Garden Design Worksheet <br /> The top of the ponded surface area below the overflow shall be at least 13.5%of the net new impervious <br /> surface area draining to the rain garden. Projects that have a greater contributing impervious area to <br /> the BMP shall use the larger of the two areas, or as an alternative may have the BMP sized by an <br /> Engineer using a continuous runoff model to meet the flow control requirements of Section 6.10 of the <br /> DCSS. The table below provides design geometry based upon contributing impervious area.Refer to the <br /> Rain Garden Handbookfor Western Washington:AGuidefor Design,Installation,and Maintenance <br /> (Hinman et.al. 2013) for construction guidance. Bioretention shall be designed in accordance with <br /> section 6.10 of the DCSS and the SWMMWW. Use the following criteria for design of the <br /> bioretention pond. <br /> SEE BIORETENTION EXAMPLE AT THE BACK OF THIS PACKET FOR REFERENCE <br /> The applicable Setback requirements in Section 4-4.I (3) have been met, including: <br /> • 50 feet setback from slopes greater than 15 percent and greater than 10 feet in height. <br /> Minimum Side Slope = 3:1 Minimum Infiltration Rate = 0.3 in/hr <br /> Minimum depth of Biosoil = I2-inches Ponding depth = 6-inches <br /> Freeboard = 6-inches <br /> Table 2B— Small Project Rain Garden Flow Control Design Sizing <br /> e � e <br /> 200 to 400 54 19 <br /> 400 to 600 81 36 <br /> 600 to 800 108 55 <br /> 800 to 1000 135 74 <br /> 1000 to 1200 162 95 <br /> 1200 to 1400 189 116 <br /> 1400 to 1600 216 137 <br /> 1600 to 1800 243 158 <br /> 1800 to 2000 270 180 <br /> • Net new impervious area requiring mitigation(ft2): <br /> • Contributing impervious area to BMP: <br /> • Total contributing area including landscaped area (ft2): <br /> Design Top of Ponded Surface Area (ft2)=0.135*(contributing impervious area (ft2)) <br /> ft2 <br /> City of Everett Public Works <br /> Small Project Stormwater Site Plan Report for Projects in 15 <br /> the Combined Sewer Area-September 2022 <br />
The URL can be used to link to this page
Your browser does not support the video tag.