Laserfiche WebLink
MICROINVERTERS SPECIFICATION PV MODULE RATING A STC Rooftop conductor ampacities designed in compliance with 120% RULE <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-410M art. 690.8, Tables 310.15(B)(1), 310.15(C)(1), 310.15(B)(2), 0 <br /> MICROINVERTER MODEL NO. DS3-L 310.16, Chapter 9 Table 4, 5, &9. Locations specific BUS BAR RATING X 120%) - MAIN BREAKER RATING infinit solar <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS p p infinity <br /> solar <br /> AC OUTPUT 768 W temperature obtained from ASHRAE 2017 data tables = MAX. PV OCPD <br /> MAX INPUT VOLTAGE 60 V MAX.POWER POINT VOLTAGE(VMP) 31.30 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 3.20 A OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS (200A x 120%) - 200 = 40A 6405 E MILL PLAIN <br /> VANCOUVER WA 98661 <br /> PHONE:1-800-818-0598 <br /> MAX OUTPUT VOLTAGE 240 V SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS RECORD LOW TEMP 5°CINFINITY SOLAR.COM <br /> MODULE: (18)ZNSHINESOLAR ZXM7-SH108-410M NOM.MAX.POWER AT STC(PMAX) 410 WATT AMBIENT TEMP(HIGH TEMP 2%) 26°C THIS PANEL IS FED BY MULTIPLE SOURCES <br /> INVERTER: (09)AP SYSTEMS DS3-L MAX.SYSTEM VOLTAGE 1500V CONDUIT HEIGHT 7/8" (UTILITY AND SOLAR) REVISIONS <br /> Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 48°C AC OUTPUT CURRENT 29A Initial Design 4/24/24 00 <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT NOTE: (SOLAR PV SYSTEM EQUIPPED WITH CONDUCTOR TEMPERATURE RATE 901c NOMINAL AC VOLTAGE 240V <br /> WITHIN 10' OF UTILITY METER <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED I E <br /> NOTE : WITHIN 3FT OF AC DISCONNECT. POINT OF INTERCONNECT, LOAD SIDE Signature with Seal <br /> ATTIC RUN -YES EXISTING 240V/200A BUS BAR RATING, <br /> SHUTDOWN - NO MAIN SERVICE PANEL, SINGLE PHASE, <br /> WITH A 200A MAIN BREAKER <br /> UTILITY COMPANY-SNOHOMISH COUNTY <br /> UTILITY METER#89 221 646 <br /> EXISTING <br /> (18) ZNSHINESOLAR ZXM7-SH108-410M BI-DIRECTIONAL <br /> (09) AP SYSTEMS DS3-L INVERTERS (N) 125A COMBINER PANEL, (N)BLADE TYPE UTILITY METER, Project Name& <br /> 'V' 1-PHASE,3W, Address <br /> BRANCH 1 240V,3W,l-PHASE 10 MODULES WITH 05 MICRO INVERTERS NON-FUSIBLE AC DISCONNECT120V/240V <br /> NEMA 3R 60A-2P 120/240VAC <br /> (VISIBLE, LOCKABLE, LABELED) U <br /> 200A E--{ z <br /> LU <br /> LU <br /> (E)LOADS � Q <br /> LU 00 <br /> �' <br /> p Q Q <br /> (N)JUNCTION BOX Q z z <br /> L J L J L J L J L J } Q � 1. <br /> 600 V, NEMA 4 20A (N)PV BREAKER Co LU J <br /> N UL LISTED 40AI2P 0 p w o < <br /> ---------- ---------- ---------- ---------- <br /> BRANCH 2-08 MODULES WITH 04 MICRO INVERTERS 20A L1 � z o w a w <br /> L1 L1 L2 �� <br /> O N W <br /> L2 L2 W <br /> J <br /> L1 L1 O <br /> L2 L2 --- ---------- <br /> G --- ----- ----- <br /> U <br /> G <br /> — <br /> Sheet Name <br /> ___----� EXISTING GROUNDING 3-LINE <br /> ELECTRODE SYSTEM DIAGRAM <br /> Sheet Size <br /> ANSI B <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE SIZE\TYPE\AMP. WIRE #C.C.C. CONDUIT TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE 11" X 17„ <br /> TAG# DEVICES RATING MULT CURR X125% OCP DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(/a) <br /> Sheet Number <br /> 05 x 3.20 x N/A = 16.00A 20.00A #10\THWN \40A @90°C 20A 2 TRUNK <br /> AIR BLE 1.00 x 1.00 x 40A 40.00A <br /> 16.00A #6 AWG 20 0.28 E 1 .1 <br /> O 05 x 3.20 x N/A = 16.00A 20.00A #10\THWN \40A @90°C 20A 4 3/4" EMT 1.00 x 0.80 x 40A 32.00A 16.00A #8 AWG 35 0.48 0.93< <br /> 2 <br /> O09 x 3.20 x N/A = 28.80A 36.00A #8 \THWN \ 50A @75°C 40A 2 3/4" EMT 1.00 x 1.00 x 50A 50.00A 28.80A #8 AWG 10 0.17 <br />