CEILING JOIST/ MAXIMUM MAXIMUM TOTAL PV ARRAY AREA(W) 320.03 <br /> PANEL AZIMUTH PITCH TSRF AREA FRAMING SIZE <br /> ROOF MATERIAL SHEATHING TYPE FRAMING TYPE PURLINS SIZE RACKING TYPE ATTACHMENT TYPE ATTACHMENT CANTILEVER TOTAL ROOF AREA(ft') 1301 <br /> COUNT (DEG) (DEG) (%) (ft') AND SPACING AND SPACING SPACING(S) (C) DISTRIBUTED LOAD(psf) 2.2 <br /> MP) 6 181 18 93 261 Comp Shingle PLYWOOD Rafter 2x4 @ 16 in OC 2x6 @ 16 in OC UNIRAC SFM INFINITY UNIRAC SFM INFINITY FLASHKIT 72"L/48"P 24"L/16"P ROOF COVERAGE(%) 24.6 <br /> MP3 0 J1 34 75 544 Comp Shingle PLYWOOD Rafter 2x4 @ 16 in OC 2x6 @ 16 in OC UNIRAC SFM INFINITY UNIRAC SFM INFINITY FLASHKIT 72"L/48"P 24"L/16"P TOTALPV ARRAY <br /> WACHMENTS 4 <br /> 7055 <br /> ALBLUE RAVEN <br /> MP4 1 0 POINT LOAD(Ibs/att.) 15.7 SOLAR <br /> MP5 0 <br /> MP6 0 1403 N 630 E <br /> MP7 0 Orem, Utah 84097 <br /> MP8 0 (800) 377-4480 <br /> MP9 0 BlueRavenSolar.com <br /> MEW 0 <br /> ATTACHMENT TYPE: <br /> PV MODULES SHALL NOT EXTEND Unirac SFM Infinity <br /> ABOVE ROOF RIDGE LINE <br /> Gf <br /> 0 <br /> PV MODULE <br /> MAX CANTILEVER } <br /> PER TABLE ABOVE— <br /> (C) <br /> BOVE(C) _ t <br /> N <br /> UNIRAC UNIRAC Q Q <br /> PV MODULE SFM INFINITY SFM INFINITY CV <br /> 2"MICRORAIL 6.5"SPLICE } 00 <n <br /> } <br /> Q O N <br /> 0 <br /> ROOF MATERIAL NOT N } > <br /> SHOWN FOR CLARITY EXISTING FRAMING It[*Q LU U <br /> m O Z _Q <br /> O O tO <br /> 2YMIN <br /> (1)5/16"LAG BOLT EMBEDMENT <br /> WITH EPDM WASHERT T <br /> CUN } }Ii <br /> T <br /> r <br /> O <br /> ATTACHMENT SPACING U <br /> PER TABLE ABOVE <br /> (L) W <br /> rn <br /> E <br /> FRAMING SPACING <br /> FRAMING DETAIL *THIS DETAIL IS NOT MEANT TO BE PER TABLE ABOVE -C <br /> 1 EXTERIOR WALL AN EXACT REPRESENTATION OF 2 ATTACHMENT DETAIL -- r O <br /> SCALE: 1/2"= 1'-0" FRAMING OR PV MODULE LAYOUT SCALE: 1-1/2"= 1'-0" a <n <br /> RIDGE 0 <br /> NOTES 0 <br /> I I I I I I I I I I A c <br /> LANDSCAPE PORTRAIT ��(.� W, 'HYD, <br /> U Q <br /> I I �� OF nsgy yF PROJECT ID: <br /> 1 C <br /> I I <br /> 967863 <br /> I I — <br /> PV DC SYSTEM SIZE: <br /> I I <br /> 2;: �� 6.150 kW DC <br /> O� f� PV AC SYSTEM SIZE: <br /> Ff C/STEa V� 4.875 kW AC <br /> S�ONAL � <br /> I I REVISIONS: <br /> I I <br /> 04/23/2024 0 <br /> 0 ---- <br /> I I <br /> I <br /> I A ---- <br /> I <br /> I I <br /> DRAWN BY: <br /> Brendan Fillmore <br /> PLOT DATE: <br /> April 23,2024 <br /> I <br /> DRAWING TITLE: <br /> 7 7 <br /> I I I <br /> I I I I I I I I I <br /> FOLLOW ATTACHMENT SPACING IN TABLE ABOVE Structural <br /> EA VE *ATTACHMENT PATTERN SHOULD BE DRAWING NUMBER: <br /> ATTACHMENT PATTERN STAGGERED UNLESS OTHERWISE PV4 <br /> SCALE: 1/4"= 1'-0" NOTED IN ENGINEERING LETTER <br />