Laserfiche WebLink
Ll (1) 10 AWG THHN/THWN-2 CU BLACK Ll (1) 10 AWG THHN/THWN-2 CU BLACK 1_1 (2) 10 AWG THHN/THWN-2 CU BLACK 3/4 INCH Ll (1) 10 AWG THHN/THWN-2 CU BLACK 3/4 INCH Ll (1) 12 AWG THHN/THWN-2 CU BLACK <br /> 5 1_2 (1) 10 AWG THHN/THWN-2 CU RED L2 (1) 10 AWG THHN/THWN-2 CURED L2 (2) 10 AWG THHN/THWN-2 CURED EMT L2 (1) 10 AWG THHN/THWN-2 CU RED L2 (1) 12 AWG THHN/THWN-2 CU RED 4 N (1) 10 AWG THHN/THWN-2 CU WHITE 3 G (1) 10 AWG THHN/THWN-2 CU GREEN 2 G (1) 10 AWG THHN/THWN-2 CU GREEN 1 G (1) 6 AWG BARE,CU <br /> G (1) 10 AWG THHN/THWN-2 CU GREEN G (1) 10 AWG THHN/THWN-2 CU GREEN *TYPE OF CABLE MAY BE SUBSTITUTED FOR USE IN 'TYPE NM(ROMEX)/UF CABLE IS PERMITTED FOR INTERIOR <br /> 3/4 INCH EMT Exterior 3/4 INCH EMT Exterior CONDUIT WHERE NEC CODE PERMITS OR ATTIC RUNS AND SHALL BE USED WHEN NEC CODE PERMITS ENPHASE Q-CABLE,2-WIRE,FREE AIR Exterior BLUE RAVEN <br /> SOLAR <br /> KT SAj y 1403 N 630 E <br /> p0 of W. SH�fTy Orem, Utah 84097 <br /> (800) 377-4480 <br /> BlueRavenSolar.com <br /> -- PRIMARY PV COMBINER BOX <br /> OVERHEAD SERVICE 0 0 0—PRIMARY STRUCTURE <br /> 120/240 VAC,60 Hz 97 <br /> 1 PHASE,3 WIRE _ `� 15A , 8(15)PV MODULES <br /> AC DISCONNECT 0� ��. �0 O <br /> SAFETY SWITCH (i/$TE B sMICROINVERTERS <br /> O 30A NON-FUSIBLE 'ss^, `C�l (N)20A O PV CIRCUIT 1 1 C I PVA RR AY 1 <br /> UtilityMeter E 200A Main Service Panel f 4 Q <br /> (D — 8 MODULES — <br /> 04/23/2024 ENVOY 1 2 -1 I 1 <br /> (E)200A (N)20A I I I <br /> N I PV CIRCUIT 2 } <br /> (EL) r--- G — 7MODULES---I i <br /> 3 2 L J N <br /> � I Q <br /> (EL) LI I �- C4 <br /> L } N 0- N <br /> (EL) — �c ---- -------------------------- - -------------------G -�1 r. > C } <br /> (EL) I MM � <br /> I W � LU <br /> (PV)30A 1 <br /> 0 0 IL <br /> N 1 V N 3 > <br /> I U } <br /> E I � M } � <br /> 0 <br /> G U 1 I > <br /> N <br /> 0 <br /> I � <br /> O / CJ ro <br /> Z <br /> GENERAL NOTES I o N <br /> Utility Meter Number:1000545718 <br /> O F <br /> Load side breaker in MSP.Interior POI. <br /> Trenching not required,exterior conduit can be run between the two structures by )' v a <br /> overhanging section between them. LEGEND , PROJECT ID: <br /> (E) EXISTING (PV) PV BREAKER _ �-` 967863 <br /> (N) NEW (FIB) FACTORY INSTALLED BREAKER <br /> (EL) EXISTING LOADS SPD SURGE PROTECTIVE DEVICE ` PV DC SYSTEM SIZE: <br /> (RL) RELOCATED LOADS MI MECHANICAL INTERLOCK 6.150 kW DC <br /> 40 �-210 • „ ,,,t�ti --_1 � PV AC SYSTEM SIZE: <br /> EQUIPMENT NOTES O EQUIPMENT DESCRIPTIONS , tui �� 200 2�OV � T4 M�98 , �, 4.875 kW AC <br /> OFINAL CONFIGURATION OF PV CIRCUITS TO BE DECIDED BY INSTALLER.MUST COMPLY WITH MAX APV MODULE:Silfab Solar SIL-410 HC+,410 W DC,UL 1703/UL 61730 COMPLIANT f11� 1J IM6111 4042 TAX KA TO <br /> MICROINVERTERS PER CIRCUIT AS LISTED ON ATTACHED SPEC SHEET. ©MICROINVERTER:ENPHASE IQ8M-72-M-US,325 W AC(0.325 kW),1 PHASE,UL 1741 COMPLIANT COUNTY 0 Kt t 0 REVISIONS: <br /> < ©ROOFTOP JUNCTION BOX:EZ SOLAR JB-1.2 JUNCTION BOX P", ` Q ---- <br /> 0 JUNCTION BOX:PVC 4 X 4 JUNCTION BOX 1545718 <br /> OQE PV COMBINER BOX:ENPHASE IQ COMBINER 4(X-IQ-AM1-240-4) ��Likw) 1i B <br /> O QF SQUARE-D SAFTEY SWITCH 30A,2P,240VAC,NON-FUSIBLE(DU221 RB) rti44742M Q ---- <br /> AIM <br /> DRAWN BY: <br /> `�� Brendan Fillmore <br /> OO PLOT DATE: <br /> O © April 23,2024 <br /> 8 © <br /> OTHER NOTES 0 DRAWING TITLE: <br /> OElectrical9 GROUNDING ELECTRODE SYSTEM SHALL BE IN ACCORDANCE WITH NEC 250.53. 0 <br /> ,o ©--- 3-Line <br /> ® DRAWING NUMBER: <br /> 11 <br /> 12 O ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. PV5 <br />