Laserfiche WebLink
=Y <br /> O 0 <br /> J N <br /> =m 6, <br /> Key Mechanical Refrigeration Schedule-Letter Format a <br /> woz� <br /> x I-x <br /> Washington Version 2.00 Dated 8/5/15 0 ° <br /> Customer: SAM'S CATS AND DOGS EVERETT I Date: 06/11/24 z N <br /> Location: EVERETT,WA 0 w <br /> File#: •ICI Z <br /> APPROX. LOCATION OF I��II O. <br /> NEW REMOTE COMPRESSOR WwO" <br /> S stem/Case/Coil Data: w. <br /> Y Total Case/Coil o� <br /> Sys# Qty/Len Make Description Refrig Length/Doors Model <br /> 1 4-5dr HILLPHOENIX FRO EN FOOD REACH IN 20 ORZH w o <br /> Loads/Line Sh ing: Evap Disch Defrost Defrost Line Sizes 5 <br /> __x" <br /> Sys# Load Temp Temp Defrost Qty/Len Liquid o o$ <br /> Term q Suction Riser r/ w m o <br /> z� <br /> 1 20880 -7 -1 EL 46 50 o z 5 <br /> Electrical: 115V Case Electrical Loads-Totals Per System 208 Volt Defrost <br /> Sys# Fans ASH On ASH Cyc Lights Other t Phase 3 Phase Expansion Valve Fan Volts <br /> Qty EMS $> m <br /> Sys# Probes Controls Comments <br /> oR <br /> Compressor to: Com r. Capacity, 3 Y <br /> P p Suction Unit Unit Unit Dimensions, <br /> System# Unit Model Model Refrig. Temp Btu/Hr Voltage MCA Weight,Lb. L x W x H,In. <br /> 1 KRSA0351-8 R448A -7.5 26,300 208 /230 20.90 533 43 x 28 x 40 <br /> Notes: <br /> E.C.TO VERIFY AND RE-USE EXISTING AND/OR PROVIDE NEW ELECTRICAL FEED FOR NEW CASES AND EVAPORATOR COILS. <br /> E.C.TO VERIFY AND RE-USE EXISTING AND/OR PROVIDE NEW ELECTRICAL FEED FOR NEW COMPRESSORS OR CONDENSING UNITS. <br /> G.C.OR OWNER TO PROVIDE LEVEL CONCRETE PAD FOR NEW OUTDOOR CONDENSING UNITS. <br /> -G.C.OR OWNER TO PROVIDE LEVEL ROOF PAD OR TREATED REDWOOD SLEEPERS FOR NEW ROOFTOP CONDENSING UNITS. I!D <br /> G.C.OR OWNER TO PROVIDE ROOFTOP EQUIPMENT STRUCTURAL DRAWINGS AND CALCULATIONS WHEN REQUIRED. <br /> P.C.TO VERIFY AND RE-USE,RELOCATE OR PROVIDE NEW FLOOR SINK FOR NEW CASES AND EVAPORATOR COILS. <br /> G.C.TO PROVIDE ALL WALL/ROOF OPENINGS,LINE COVERS OR TRENCHING REQUIRED FOR NEW REFRIGERATION LINES. <br /> APPROX. LOCATION OF LEGEND:E=EXISTING,N=NEW,R=RELOCATED,M=MODIFIED,LLSV=LIQUID LINE SOLENOID VALVE, <br /> NEW REFRIGERATED CASE SSSV=SUCTION STOP SOLENOID VALVE. <br /> LINEUP <br /> FLOOR PLAN FOR KEY MECHANICAL USE ONLY <br /> R1.0 S-LE.,N=,-o <br /> z <br /> z <br /> O z <br /> � � o <br /> j a <br /> W p: <br /> El <br /> 0 <br /> J <br /> H <br /> z 1-- <br /> of <br /> LL LLI <br /> LU <br /> W <br /> F > <br /> LU LLI <br /> Of U) <br /> W Ur <br /> W O Q Do <br /> Cl) C) CD <br /> O D ao <br /> o Q W Q <br /> <Y <br /> Q � LLI <br /> � <br /> U W <br /> W <br /> cn cf) lY <br /> Q > <br /> W U) oo LU <br /> DATE:05/29/2024 <br /> PROD#1 23698-00 <br /> DRAFTERIBFC <br /> REVIEWED BY I-- <br /> SHEET SIZE BArch D <br /> SCALE SAS SHOWN <br /> KM PHONE 1+1(253)872-7392 <br /> FLOOR PLAN <br /> N <br /> FLOOR PLAN <br /> R1 .0 <br />