My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5/31/24,8:03 AM Mechanical Compliance Summary <br /> MECHANICAL COMPLIANCE SUMMARY <br /> 2021 WSEC Compliance Forms for Commercial Buildings including Group R1,R2,and Group R3&R4 over 3 stories Administered by:@2021 NEEA,All rights reserved <br /> Project Title 210 SW Everett Mall Way-2021 WSEC For Building Department Use: I Date: May 31,2024 <br /> Project Address 210 SW Everett Mall Way <br /> Project&Applicant Everett,WA 98208 <br /> Information Applicant Name Alex Burkhart <br /> Applicant Phone 206-763-1744 <br /> Applicant Email alexb@evergreenhvac.com <br /> Mechanical Compliance Summary Scope-Compliance verification provided in this report is limited to code minimum efficiency requirements for mechanical equipment types defined in Tables C403.3.2(1)through C403.3.2(16)of the 2021 <br /> WSEC-C.This includes efficiency multipliers for economizer exceptions.Performance criteria for additional energy efficiency and load management measures ARE NOT included in this report.Additional documentation is required to <br /> demonstrate compliance with all other provisions of the energy code,including better than code efficiency criteria for Section C406.For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at <br /> com.techsupport@waenergycodes.com. <br /> General Occupancy All Commercial General Building Use Type(s) Retail,General Sales Building Cond.Floor Area 10,928 <br /> New Building Project Cond.Floor Area 10,928 <br /> General Project Types Alteration or Addition Alteration Single Zone Systems&Equipment Floors Above Grade 1 <br /> Mechanical ScopeMechanical Scope <br /> Overall Compliance Path General Prescriptive <br /> Mechanical Project Description Installation of six(6)replacement rooftop units. <br /> Economizer Exception(s) DOAS Ventilation Equipment Efficiency <br /> Project Type Mechanical Scope lied?A Provided? <br /> Mechanical Compliance Applied? Compliance Verification <br /> Scope and Method Single Zone Systems& <br /> Alteration Yes No COMPLIES <br /> Equipment <br /> Additional Energy Efficiency Load Management Measures <br /> Measures(AEM) No mechanical additional energy efficiency measures included in project (LDM) No mechanical load management measures included in project <br /> Does building include occupancy classifications requiring DOAS? No Does project include DOAS equipment? No <br /> Do all systems comply with Appendix D standard reference design <br /> Based on project scope do TSPR requirements apply? No No <br /> or qualify for an exception to TSPR? <br /> Scope&Space Conditioning ALTERATION-SINGLE ZONE SYSTEMS&EQUIPMENT Compliance Verification COMPLIES <br /> Single Zone Air Systems Category-Air conditioner,split&single package,SC,SDHV <br /> Air Systems Summary Information <br /> Ventilation CFM <br /> Quantity Supply Airflow Ventilation Energy Recovery <br /> System/Equip ID Ventilation Standard (Total if Multiple Paired with DOAS Ventilation energy recovery <br /> of Items Control Items) Air Source Efficiency(%) <br /> RTU-1 Constant volume IMC Ventilation Integral Not provided,not required <br /> RTU-2 Constant volume IMC Ventilation Integral Not provided,not required <br /> RTU-31 I Constant volume IMC Ventilation Integral Not provided,not required <br /> RTU-4 Constant volume IMC Ventilation Integral Not provided,not required <br /> RTU-5 Constant volume IMC Ventilation Integral Not provided,not required <br /> RTU-6 Constant volume IMC Ventilation Integral Not provided,not required <br /> Air Systems&Equipment-Cooling <br /> https://waenergycodes.com/print_project_summary_form/mec?project_id=26574&form_version_id=24 1/3 <br />