Laserfiche WebLink
5/31/24,8:03 AM Mechanical Compliance Summary <br /> Econo Exception Required Cooling Required Part <br /> System/ Cooling Capacity Proposed Cooling CE Proposed Part PL Efficiency Compliance <br /> Equip ID Cooling System/Equip Type Specific Type per item(Btu/h) Multipliers Efficiency Load Efficiency Efficiency Units Load Efficiency Units Verification <br /> (Full/IPLV) (Code Min+Econo) (Code Min+Econo) <br /> RTU-1 Air conditioner,air cooled Single package DX 86,000 0 0 11.0 14.6 11 EER 14.6 IEER COMPLIES <br /> RTU-2 Air conditioner,air cooled Single package DX 47,500 0 0 13.4 0 13.4 SEER2 IEER COMPLIES <br /> RTU-3 Air conditioner,air cooled Single package DX 47,500 0 0 13.4 0 13.4 SEER2 IEER COMPLIES <br /> RTU-4 Air conditioner,air cooled Single package DX 47,500 0 0 13.4 0 13.4 SEER2 IEER COMPLIES <br /> RTU-5 Air conditioner,air cooled Single package DX 47,500 0 0 13.4 0 13.4 SEER2 IEER COMPLIES <br /> RTU-6 Air conditioner,air cooled Single package DX 58,500 0 0 13.4 0 13.4 SEER2 IEER COMPLIES <br /> Air Systems&Equipment-Heating <br /> Cooling Capacity Required Proposed <br /> System Heating System/Equip Type Specific Type Low OSA Low OSA Heat Pump per Item(Btu/h) Required Heat Pump Proposed Heat Pump HPH LTH Efficiency Compliance <br /> /Equip ID Heating Capacity(Btu/h) (Identical to Heating Efficiency Temp Efficiency Heating Efficiency Units Temp Efficiency Units Verification <br /> Cooling Table) <br /> RTU-1 Furnace Warm air,gas fired(AFUE),weatherized 0 0 COMPLIES <br /> RTU-2 Furnace Warm air,gas fired(AFUE),weatherized 0 0 COMPLIES <br /> RTU-3 Furnace Warm air,gas fired(AFUE),weatherized 0 0 COMPLIES <br /> RTU-4 Furnace Warm air,gas fired(AFUE),weatherized 0 0 COMPLIES <br /> RTU-5 Furnace Warm air,gas fired(AFUE),weatherized 0 0 COMPLIES <br /> RTU-6 Furnace Warm air,gas fired(AFUE),weatherized 0 0 COMPLIES <br /> Air Systems&Equipment Details <br /> System/Equip ID Discrete Area(s)Served Location In Project Documents-Plan/Detail# System/Equip Compliance Path <br /> RTU-1 Retail All General Prescriptive <br /> Heating Section/Auxiliary Heating Type:Fuel-fired Economizer Compliance Method:Air-side economizer provided <br /> WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(1)Unitary Air Conditioners&Condensing Units <br /> WSEC Equip Efficiency Reference Table-Heating: <br /> RTU-2 Retail I All General Prescriptive <br /> Heating Section/Auxiliary Heating Type:Fuel-fired Economizer Compliance Method:Air-side economizer provided <br /> WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(1)Unitary Air Conditioners&Condensing Units <br /> WSEC Equip Efficiency Reference Table-Heating: <br /> RTU-3 Retail I All General Prescriptive <br /> Heating Section/Auxiliary Heating Type:Fuel-fired Economizer Compliance Method:Air-side economizer provided <br /> WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(1)Unitary Air Conditioners&Condensing Units <br /> WSEC Equip Efficiency Reference Table-Heating: <br /> RTU-4 Retail I All General Prescriptive <br /> Heating Section/Auxiliary Heating Type:Fuel-fired Economizer Compliance Method:Air-side economizer provided <br /> WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(1)Unitary Air Conditioners&Condensing Units <br /> WSEC Equip Efficiency Reference Table-Heating: <br /> RTU-5 Retail I All General Prescriptive <br /> Heating Section/Auxiliary Heating Type:Fuel-fired Economizer Compliance Method:Air-side economizer provided <br /> WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(1)Unitary Air Conditioners&Condensing Units <br /> WSEC Equip Efficiency Reference Table-Heating: <br /> RTU-6 Retail I All General Prescriptive <br /> Heating Section/Auxiliary Heating Type:Fuel-fired Economizer Compliance Method:Air-side economizer provided <br /> WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(1)Unitary Air Conditioners&Condensing Units <br /> https://waenergycodes.com/print_project_summary_form/mec?project_id=26574&form_version_id=24 2/3 <br />