My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA C403.3.2.6 Electric heating/ Verify all packaged and split electric <br /> cooling equipment equipment with>6,000 Btu/h cooling <br /> capacity and any amount of heating is a heat <br /> pump with reverse-cycle defrost and operates <br /> in heat pump mode when outdoor air <br /> temperature is>25 degree F;include in <br /> equipment schedules <br /> NA C403.3.2.6 Electric heating/ Verify electric heat in the main supply duct <br /> cooling equipment before VAV boxes served by cooling only <br /> systems>6,000 Btu/h is a heat pump with <br /> reverse-cycle defrost and operates in heat <br /> pump mode when outdoor air temperature is <br /> >25 degree F;include in equipment <br /> schedules. <br /> NA C401.3 HVAC Heating Fuel For all heating equipment,identify whether it <br /> C403.1.4 qualifies for the C403.1.4 general prescriptive <br /> path,a C403.1.4 exception,or for the C401.3 <br /> Fossil Fuel Heating path;for equipment <br /> qualifying for the C403.1.4 general <br /> prescriptive path by exception,document the <br /> exception and provide supporting information <br /> NA C401.3 HVAC Heating Fuel For projects with equipment utilizing the <br /> C403.1.4 C401.3 Fossil Fuel Heating path,provide an <br /> C406.1 accounting of the total heating capacity and <br /> the C401.3 equipment heating capacity for <br /> each distinct area utilized in the C406 <br /> calculation. <br /> NA C403.1.4 HVAC Heating Fuel, To qualify for exception 2,provide a list of <br /> exception 2 Dwelling each separate space in the dwelling or sleeping <br /> and sleeping units unit,indicate the number of exterior walls the <br /> space has,the presence of fenestration,and <br /> the allowed watts;document the heat provided <br /> in each space is below the allowed capacity in <br /> the space <br /> NA C403.1.4 HVAC Heating Fuel, To qualify for exception 5,provide <br /> exception 5 Air-to-air documentation that the heat pump is sized to <br /> heat pumps meet the heating load at an outdoor air <br /> temperature<_32°F and has a ratio of heating <br /> capacity at 47°F to supplemental resistance <br /> heat capacity>_2.0 in zone 4 and>_ 1.0 in <br /> zone 5;indicate unit control by either a <br /> thermostat designed for heat pump use,a <br /> multistage thermostat with an outdoor air <br /> temperature thermostat wired to energize <br /> supplemental heat only on the last stage or <br /> heating and when the outdoor air temperature <br /> is<_32°F,or equipment is NAECA rated with <br /> integral control <br /> Page 2132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.