My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA C403.1.4 HVAC Heating Fuel, To qualify for exception 6,provide <br /> exception 6 Air-to- documentation that building heating is <br /> water heat pumps provided by air-to-water heat pumps with a <br /> heating capacity>_75%of the design heating <br /> load at 29°F;indicate controls configured to <br /> lock out supplemental heat when the outdoor <br /> air temperature is>36°F unless the hot water <br /> supply set point has not been maintained for <br /> 20 minutes;indicate controls configured to <br /> use the compressor as the first stage of <br /> heating down to the compressor minimum <br /> rated temperature except during start up and <br /> defrost <br /> NA C403.1.4 HVAC Heating Fuel, To qualify for exception 7,provide <br /> exception 7 Ground documentation building heating provided by <br /> source heat pumps ground source heat pumps;;indicate controls <br /> configured to lock out supplemental resistance <br /> heat when the source-side entering water <br /> temperature is>_42°F unless the hot water <br /> supply set point has not been maintained for <br /> 20 minutes;indicate controls configured to <br /> use the compressor as the first stage of <br /> heating;indicate the ground source heat <br /> exchanger shall be sized so heat pump annual <br /> output is>_70%for the total annual heating <br /> output based upon the final year of a 30-year <br /> simulation using IGSHPA listed software <br /> NA C403.1.4 HVAC Heating Fuel, To qualify for exception 8,document the <br /> exception 8 Small capacity or area served for the electric <br /> systems resistance and fossil fuel systems and <br /> demonstrate that it is<_5%of the building <br /> total heating capacity or area <br /> NA C401.3.6 Electrification For all equipment following the fossil fuel <br /> readiness path,indicate on plans that spare electrical <br /> branch circuit and service entrance conduit is <br /> installed and sized to support future <br /> conversion of fossil fuel heaters to heat <br /> pumps;indicate on plans additional room in <br /> the electric room and transformer rooms and <br /> vaults be provided and sized to accommodate <br /> future service upgrades for conversion of all <br /> fossil fuel equipment to heat pumps. <br /> NA C403.3.1 Equipment and Indicate that output capacities of heating and <br /> system sizing cooling equipment and systems are no greater <br /> than the smallest available equipment size that <br /> exceeds the calculated loads;note exceptions <br /> applied <br /> YES C403.3.2 HVAC equipment Provide equipment schedules on plans and in M001 <br /> C403.9.1 performance WSEC mechanical equipment compliance <br /> requirements reports;indicate equipment type,calculated <br /> (efficiency) loads,capacity,rated and WSEC minimum <br /> efficiencies for all heating and cooling <br /> equipment;include supply and ventilation air <br /> cfms and operating hours for all air systems; <br /> identify heating and cooling equipment that <br /> does not have a corresponding WSEC <br /> minimum efficiency(manufacturer rated) <br /> Page 3132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.