210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.3.5 Dedicated outdoor air For buildings with occupancies required to <br /> C403.3.5.4 systems comply with the DOAS provisions per Table <br /> C403.3.5,identify on plans all occupancies in <br /> the building and indicate which occupied <br /> spaces are required to have ventilation air <br /> delivered by a DOAS;or exception applied <br /> C403.3.5 Dedicated outdoor air If natural ventilation exception is applied, <br /> C403.3.5.4 systems identify these spaces on plans;indicate <br /> operable window area complies with IMC <br /> Section 402;provide documentation <br /> describing how required ventilation will be <br /> provided during all occupied hours,including <br /> during inclement weather <br /> C403.3.5 Dedicated outdoor air If high efficiency VAV exception is applied, <br /> C403.3.5.4 systems identify these spaces on plans;refer to Single <br /> Zone VAV section for Groups A-1,A-2 and <br /> A-3 occupancy classifications,or Multiple <br /> Zone VAV for other than Groups A-1,A-2 <br /> and A-3(per Table C403.3.5) <br /> C403.3.5 Dedicated outdoor air If compliance with the DOAS provisions is <br /> C403.3.5.6 systems deemed to be impractical,provide <br /> documentation that demonstrates the alternate <br /> design strategy applied that achieves a <br /> comparable level of energy efficiency,as pre- <br /> approved by the AHJ <br /> C403.3.5 Dedicated outdoor air Refer to Requirements List section after <br /> systems Multiple-Zone Air Systems for High <br /> Efficiency Multiple-Zone VAV Systems <br /> exception to C403.3.5 DOAS <br /> C403.3.5 Dedicated outdoor air Refer to Requirements List section after High <br /> systems Efficiency Multiple-Zone Air Systems for <br /> High Efficiency Single-Zone VAV Systems <br /> exception to C403.3.5 DOAS <br /> C403.3.5.1 DOAS energy For all DOAS systems,indicate exhaust air <br /> recovery method and ER method and basis of rated effectiveness <br /> effectiveness (sensible or latent);indicate Z 68%sensible or <br /> >60%enthalpy recovery ratio at design <br /> conditions;or exception applied <br /> C403.3.5.2 DOAS fan power For DOAS with no fans or fan arrays with <br /> input power z 1kW,indicate total system fan <br /> power does not exceed 1 watt per cfm <br /> C403.3.5.2 DOAS fan power For DOAS with any fans or fan arrays with <br /> input power>_ 1kW,indicate total system fan <br /> power complies with fan power limitation per <br /> Section C403.8.1 <br /> C403.3.5.3 Heating/cooling Indicate systems and equipment associated <br /> system fan controls with the delivery of zone level heating and <br /> with DOAS cooling(fans,hydronic pumps,primary air <br /> dampers,etc.)are configured to shut off,and <br /> central equipment is configured to turn down, <br /> when there is no call for heating or cooling in <br /> the zone they serve <br /> Page 5132 <br />