My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.3.5.3 Heating/cooling If applying Exception to heating/cooling fans <br /> system fan controls used for air mixing in the space during <br /> with DOAS deadband periods,include fan watts per cfm <br /> in equipment schedule <br /> C403.3.5.4 Decoupled DOAS Indicate method of delivery of DOAS supply <br /> supply air air to the occupied space(directly into space, <br /> downstream of terminal heating/cooling <br /> coils);or exception applied <br /> C403.6.5 Multiple zone DOAS For DOAS serving multiple zones with DDC <br /> controls,indicate controls configured to <br /> reduce the volume of outdoor air in each zone <br /> independently when the zone is unoccupied; <br /> or exception applied <br /> ADDITIONAL ENERGY EFFICIENCY MEASURE-DEDICATED OUTSIDE AIR SYSTEMS(DOAS) <br /> C406.2.2.6 High performance For all building occupancies,to comply with <br /> DOAS-Energy this additional efficiency credit,demonstrate <br /> recovery compliance withC403.3.5 <br /> effectiveness and fan <br /> power <br /> C406.2.2.6 High performance Indicate energy recovery sensible <br /> DOAS-Energy effectiveness of all DOAS is>_80% <br /> recovery <br /> effectiveness and fan <br /> power <br /> C406.2.2.6 High performance For each system,indicate that total system fan <br /> DOAS-Energy power does not exceed 0.769 watts per cfm or <br /> recovery is<_80%of the fan power allowance for a <br /> effectiveness and fan constant volume system calculated per <br /> power C403.8.1 <br /> FANS AND FAN CONTROLS <br /> YES C403.8.1.2 Fan power limitation For all HVAC fan systems associated with M001 <br /> conditioned space and containing 1 or more <br /> fans with electrical input>_1 kW shall <br /> provide the total nameplate hp and the fan <br /> system electrical input power calculated per <br /> C403.8.1.2 in equipment schedules on project <br /> plans <br /> NA C403.8.1.1 Fan power limitation For all HVAC and DOAS systems associated <br /> with conditioned space with 1 or more fans <br /> with electrical input power> 1 kW,provide <br /> fan system electrical input power calculations <br /> per Section C403.8.1.2 to verify it complies <br /> with fan power budget per Section C403.8.1.1 <br /> NA C403.8.2 Motor nameplate hp For HVAC systems with total fan motor <br /> nameplate hp>5hp,indicate fan motors <br /> specified are the smallest available motor hp <br /> size greater than fan bhp,note exceptions <br /> applied <br /> Page 6132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.