My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA C405.8 Fractional hp fan For all fractional hp fan motors(1/12-<1 <br /> motors hp),indicate that motors comply with <br /> applicable WSEC efficiency tables;if motor <br /> type is not listed in an efficiency table, <br /> indicate whether fan has an electronically <br /> commutated motor,has motor rated <br /> efficiency of at least 70%,or exception <br /> applied <br /> NA C403.8.3 Fan efficiency For individual fans or fan arrays,indicate in <br /> equipment schedule that rated FEI for all <br /> applicable fans part of a variable-air volume <br /> system is>_0.95 and>_ 1.0 in all other <br /> systems,or exception applied;indicate these <br /> fans are sized at the design point of operation <br /> C403.8.4 Low-capacity For all ventilation system fans with motors<_ <br /> ventilation fans 1/12 hp,indicate in equipment schedule the <br /> fan flow rate and efficacy(cfm/watt),or <br /> exception applied;refer to Table C403.8.4 <br /> NA C403.2.4 Variable flow For fan motors>_5 hp,indicate method of <br /> capacity-fans variable flow control(VSD or equivalent <br /> method)in equipment schedule,or exception <br /> applied <br /> NA C403.8.5.1 Fan airflow control For DX air handling units with cooling <br /> capacity>42,000 Btu/h and evaporative and <br /> chilled water air handling units with fan>_ <br /> 0.25 hp,indicate whether system is single <br /> zone or multiple zone and related control <br /> method(cooling capacity controlled in <br /> response to space temperature,space <br /> temperature is controlled by modulating <br /> supply airflow,or both) <br /> NA C403.8.5.1 Fan airflow control For mechanical cooling systems(includes DX <br /> and chilled water coils)that control cooling <br /> capacity in response to space temperature- <br /> Provide a minimum of two stages of fan <br /> control;indicate minimum fan speed is<_ <br /> 66%of full speed drawing<_40%of full <br /> speed fan power during periods of low cooling <br /> or ventilation only <br /> NA C403.8.5.1 Fan airflow control For other mechanical cooling systems <br /> (includes DX and chilled water coils)that <br /> control space temperature by modulating <br /> airflow(in lieu of,or in addition to, <br /> controlling capacity in response to space <br /> temperature)-Provide fan controls for <br /> modulating supply airflow;indicate minimum <br /> fan speed is<_50%of full speed drawing<_ <br /> 30%of full speed fan power during periods of <br /> low cooling or ventilation only;or exception <br /> applied <br /> NA C403.8.6 Large-diameter Where provided,indicate large-diameter <br /> ceiling fans ceiling fans to be tested and labeled in <br /> accordance with AMCA 230. <br /> ADDITIONAL ENERGY EFFICIENCY MEASURE-IMPROVED HVAC TSPR <br /> Page 7132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.