My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA C406.2.2,3 More efficient In addition to system selection requirement, <br /> C406.2.2.3.2 HVAC equipment demonstrate that 90%or more of all HVAC <br /> heating performance heating capacity serving the building or credit <br /> area is delivered by equipment at least 5% <br /> better than the listed WSEC efficiency, <br /> seasonal or annualized where available other <br /> wise use full load efficiency <br /> NA C406.2.2.3 More efficient For projects prorating the credit in <br /> C406.2.2.3.2 HVAC equipment accordance per Equation 4-16 include <br /> heating performance calculations for equipment representing at <br /> least 90%of the heating capacity serving the <br /> building or credit area that demonstrate the <br /> capacity weighted average better than code <br /> efficiency;for equipment with multiple code <br /> requirements the seasonal or annualized <br /> efficiency shall be used <br /> NA C406.2.2.3 More efficient In C402.1.1 low energy and C402.1.1.2 semi- <br /> C406.2.2.3.2 HVAC equipment heated spaces demonstrate that 90%of the <br /> heating performance heating capacity in the building or area is <br /> provided by electric infrared or gas-fired <br /> radiant equipment for localized heating <br /> applications. <br /> VENTILATION,EXHAUST&ENERGY RECOVERY <br /> NA C403.7.1.2 Demand control For each required demand control ventilation <br /> ventilation design system,indicate outdoor air automatically <br /> changes in response to a CO2 sensor and <br /> utilizes a variable speed fan control to reduce <br /> systems flow;or exception applied <br /> C403.2.2.1 Ventilation If mechanically delivered,indicate that <br /> ventilation systems are configured to provide <br /> not more than 150%of,but at least the <br /> minimum required volume of outdoor air to <br /> each zone per IMC,ASHRAE 62.1 or other <br /> applicable code(WAC,OSHA,etc.);or <br /> exception applied <br /> C403.2.2.1 Ventilation If delivered via natural ventilation,identify <br /> required elements per IMC including: <br /> minimum openable area to the outdoors or <br /> qualifying adjoining spaces;criteria for <br /> ensuring required ventilation is provided <br /> during all occupied hours of the year <br /> (including during inclement outdoor <br /> conditions) <br /> C403.2.2.2 Exhaust Indicate that exhaust systems are configured <br /> to provide not more than 150%of,but at least <br /> the minimum required volume from each <br /> zone per IMC,or other applicable code <br /> (WAC,OSHA,etc.);or exception applied <br /> C403.4.2.4 Exhaust system off- Refer to Requirements List section HVAC <br /> hour controls Controls for off-hour controls requirements <br /> for exhaust systems <br /> Page 9132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.