Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.7.6.1 Balanced ventilation For Group R-2 dwelling and sleeping units, <br /> for Group R-2 indicate that each habitable space is provided <br /> occupancy with a balanced ventilation system;indicate <br /> system is provided with energy recovery with <br /> >60%sensible recovery effectiveness <br /> C403.7.1.1 Demand control Identify spaces with ventilation provided by <br /> ventilation single zone system with air economizer;for <br /> each space indicate controls are configured to <br /> provide demand controlled ventilation or <br /> provide supporting documentation for applied <br /> exception <br /> NA C403.7.1.1 Demand control Provide list of spaces with IMC ventilation <br /> ventilation occupant load and the occupant outdoor <br /> airflow rate listed;for spaces with occupant <br /> load>_ 15 people/1,000 sf per IMC or <br /> occupant air flow rate>_ 15 cfm/person <br /> indicate controls are configured to provide <br /> demand controlled ventilation or provide <br /> supporting documentation for applied <br /> exception <br /> C403.7.2 Occupancy sensors For gyms,classrooms,auditoriums, <br /> conference rooms and other spaces with <br /> occupant load>25 people/1,000 sf per IMC, <br /> that have an area>500 sf,indicate occupancy- <br /> based ventilation air control when space is <br /> unoccupied and method(closes outdoor air <br /> damper or shuts-off equipment);or alternate <br /> means provided to automatically reduce <br /> ventilation air when space is partially <br /> occupied;or exception applied <br /> C403.7.3 Ventilation air For ventilation air systems with supplemental <br /> heating control heating capacity that operate in conjunction <br /> with heating and cooling systems,indicate that <br /> ventilation air is tempered(via heating or heat <br /> recovery)to no greater than 55°F when the <br /> space conditioning system is in cooling mode <br /> C403.7.4.2 Ventilation controls Indicate method of ventilation and exhaust <br /> for Group R-1 isolation for each guest room and automatic <br /> guestrooms controls that are configured to turn off <br /> ventilation and exhaust airflow when each <br /> room is unoccupied <br /> C403.8.4 Group R occupancy Refer to Requirements List section Fans& <br /> exhaust fan efficacy Fan Controls <br /> C403.7.5 Enclosed loading For enclosed loading docks,indicate <br /> C403.7.5.1 dock ventilation ventilation/exhaust system method of <br /> activation(gas detection system for CO and <br /> NO2,or occupancy sensors),and control <br /> method(staged or modulating);if total <br /> ventilation system fan motor nameplate <br /> horsepower is>5 hp,indicate VSD or <br /> equivalent motor drives <br /> Page 10132 <br />