My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.7.7.3 Transfer air For spaces where conditioned supply air is <br /> utilized as transfer air to balance mechanical <br /> exhaust,indicate basis of transfer airflow <br /> (supply required to meet loads,health/safety <br /> requirement,air that would normally be <br /> exhausted);or exception applied <br /> C403.7.8.1 Shutoff dampers for Indicate locations of outdoor air intake, <br /> C403.7.8.3 building isolation exhaust and relief outlet dampers on plans; <br /> indicate whether dampers are Class 1 <br /> motorized,or gravity and exception applied <br /> (include leakage rating,cfm/sf) <br /> C403.7.8.1 Shutoff dampers for Indicate location of stairway and elevator <br /> C403.7.8.3 stairway and elevator hoistway shaft vent dampers on plans;verify <br /> hoistway shaft vents dampers are Class l motorized;or exception <br /> applied <br /> C403.7.8.2 Shutoff dampers for Indicate locations of return air dampers that <br /> C403.7.8.3 return air are integral to airside economizer operation; <br /> verify dampers are motorized;indicate <br /> whether dampers are Class 1,or within <br /> packaged equipment eligible for leakage <br /> rating exception(include leakage rating, <br /> cfm/sf) <br /> C403.7.8.4 Damper actuation Indicate automatic controls configured to <br /> close outdoor air intake,exhaust and relief <br /> outlet dampers during unoccupied equipment <br /> operation;not including economizer cooling, <br /> night flush or IMC required outdoor air/ <br /> exhaust <br /> C403.7.8.4 Damper actuation Indicate method of activation of stairway and <br /> elevator hoistway shaft vent dampers(fire <br /> alarm or interruption of power) <br /> C404.11.4 Exhaust system For buildings with pools or spas with water <br /> energy recovery for surface area>200 sf,indicate exhaust air <br /> heated indoor pools energy recovery method and use of waste heat <br /> and permanent spas (preheat ventilation air,pool water or service <br /> hot water);or exception applied <br /> C404.11.4 Exhaust system Indicate energy recovery system has the rated <br /> energy recovery for effectiveness and is configured to decrease <br /> heated indoor pools the exhaust air temperature at design <br /> and permanent spas conditions by>_36°F <br /> HVAC CONTROLS <br /> NA C403.4.1 Thermostatic controls Indicate locations of thermostatic and <br /> (thermostats and humidity control devices and the zones they <br /> humidistats) serve on plans,including perimeter system <br /> zones <br /> Page 12132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.