My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.7.5 Enclosed parking For enclosed parking garages,indicate <br /> C403.7.5.2 garage ventilation ventilation/exhaust system activated by gas <br /> detection system for CO and NO2,and <br /> control method(staged or modulating);or <br /> exception applied;if total ventilation system <br /> fan motor nameplate horsepower is>5 hp, <br /> indicate VSD or equivalent motor drives <br /> C403.7.6.2 Ventilation/exhaust For systems with design ventilation air> <br /> systems energy 5,000 cfm,or design supply air cfm and% <br /> recovery ventilation air exceeding the values in Tables <br /> C403.7.6(l)or(2),indicate exhaust air energy <br /> recovery method;or exception applied with <br /> supporting calculations <br /> C403.7.6.2 Ventilation/exhaust For rooms served by multiple systems with <br /> systems energy aggregate design ventilation air>5,000 cfm, <br /> recovery or aggregate design supply air cfm and% <br /> ventilation air exceeding the values in Tables <br /> C403.7.6(1)or(2),indicate exhaust air energy <br /> recovery method;or exception applied with <br /> supporting calculations <br /> C403.7.6.2 Ventilation/exhaust Indicate energy recovery rated sensible <br /> systems energy recovery effectiveness>68%or a enthalpy <br /> recovery recovery ratio>60% <br /> C403.7.7.1.1 Kitchen exhaust hood Indicate on plans the type,duty,UL rating and <br /> C403.7.7.1.2 system exhaust airflow rate of each kitchen hood <br /> C403.7.7.1.3 <br /> C403.7.7.1.1 Kitchen exhaust hood Provide calculations that show a balanced <br /> C403.7.7.1.2 system accounting of total kitchen exhaust(include <br /> C403.7.7.1.3 all hoods)with%of:supply air,transfer air <br /> from adjacent spaces,and make-up air <br /> C403.7.7.1.1 Kitchen exhaust hood For hoods with make-up air drawn directly <br /> C403.7.7.1.2 system into the exhaust air cavity of each hood, <br /> C403.7.7.1.3 indicate that replacement air does not exceed <br /> 10%of hood exhaust airflow rate <br /> C403.7.7.1.1 Kitchen exhaust hood For kitchens with total hood exhaust <br /> C403.7.7.1.2 system exceeding 2,000 cfm,indicate that each hood <br /> C403.7.7.1.3 is UL 710 rated and maximum exhaust <br /> airflow rate of each hood is per Table <br /> C403.7.7.1.2;or exception applied <br /> C403.7.7.1.1 Kitchen exhaust hood For kitchens with total hood exhaust <br /> C403.7.7.1.2 system exceeding 2,000 cfm,indicate demand control <br /> C403.7.7.1.3 kitchen ventilation configured to a minimum <br /> 50%reduction in exhaust and replacement air <br /> system flows in response to alliance operation; <br /> or exception applied <br /> C403.7.7.2 Laboratory exhaust For buildings with total lab exhaust>5,000 <br /> systems energy cfm,indicate method of energy recovery used <br /> recovery to pre-condition laboratory make-up air; <br /> energy recovery effectiveness(min 25'F <br /> increase in outside air temperature);or <br /> alternative method per exception(VAV <br /> exhaust,semi-conditioned makeup,or CERM <br /> calculation) <br /> Page 11132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.