My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • i of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> PIPING <br /> C403.10.3 Piping insulation Indicate design temperature range of fluid <br /> conveyed in piping and thickness of insulation <br /> (in inches)on hydronic piping plans;or <br /> exception applied <br /> C403.10.3.1 Protection of piping Indicate method of protection of pipe <br /> insulation insulation from damage/degradation on <br /> hydronic piping plans <br /> NA C403.10.4 HVAC refrigerant Indicate refrigerant piping insulation to be <br /> piping insulation installed on all hot gas lines and on some <br /> liquid lines per C403.10.4;indicate insulation <br /> conductivity<0.26 Btu x in/(h x ft2 x°F) <br /> ECONOMIZERS <br /> YES C403.5 Air economizer Identify all cooling systems requiring air M001 <br /> required economizer controls in equipment schedules <br /> on plans and in WSEC mechanical equipment <br /> compliance reports <br /> NA C403.5 Air economizer Indicate all systems utilizing air economizer <br /> exceptions exceptions in WSEC mechanical equipment <br /> compliance report,including those with water- <br /> side economizer in lieu of air economizer; <br /> indicate on plans and in WSEC mechanical <br /> equipment compliance reports all eligible <br /> exception(s)taken and measures to comply <br /> with exception(s) <br /> NA C403.4.1 Integrated Indicate air and water-side economizers are <br /> C403.5.1 economizer operation configured for partial cooling operation even <br /> -air and water where additional mechanical cooling is <br /> required to meet the load <br /> NA C403.4.1 Integrated For DX air handlers with single or multiple <br /> C403.5.1 economizer operation stages of mechanical cooling;indicate controls <br /> -air and water are configured with air economizer as the first <br /> stage of cooling <br /> NA C403.4.1 Integrated Refer to Requirements List section HVAC <br /> C403.5.1 economizer operation Controls for additional requirements for DX <br /> -air and water air handlers <br /> NA C403.5.2 Economizer heating Verify control method of HVAC systems with <br /> system impact-air economizers does not increase building <br /> and water heating energy usage during normal operation <br /> NA C403.5.3.1 Air economizer Indicate modulating outdoor air and return air <br /> capacity dampers are configured to provide up to <br /> 100%outdoor air for cooling <br /> NA C403.5.1 Air economizer Indicate that economizer controls are <br /> C403.5.3.2 controls and configured to provide partial economizer <br /> integrated operation cooling when additional mechanical cooling is <br /> also required to meet the cooling load <br /> NA C403.5.1 Air economizer Indicate that control of economizer dampers <br /> C403.5.3.2 controls and is not based only on mixed air temperature;or <br /> integrated operation exception applied for systems with cooling <br /> capacity<65,000 Btu/h <br /> Page 18132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.