My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> II <br /> NA C403.4.12 Pressure independent For heating and cooling water coils with a <br /> control valves design flow>5 gpm,indicate modulating <br /> pressure independent control values are <br /> provided <br /> HYDRONIC SYSTEMS-CONTROLS <br /> C403.4.3 Boiler sequencing Indicate automatic controls that sequence <br /> operation of multiple boilers <br /> C403.4.3.2 Two-pipe changeover Indicate changeover deadband is> 15°F <br /> systems outdoor air temperature;indicate controls are <br /> configured so that heating/cooling modes are <br /> active for at minimum 4 hours before <br /> changeover and that the delta between heating <br /> /cooling supply temperatures at changeover <br /> point is <br /> C403.4.1.5 Heating water For hot water boilers that provide building <br /> temperature setback heating via one-or two-pipe systems,indicate <br /> controls that provide heating water <br /> temperature setback based on outdoor <br /> temperature <br /> C403.4.4 Hydronic system part For heating and chilled water systems with>_ <br /> load controls and 300,000 Btu/h output capacity,indicate <br /> supply-water system controls are configured to <br /> temperature reset automatically reset supply water temperature <br /> based upon demand;or exception applied <br /> C403.4.4 Hydronic system part Indicate automatic pump flow controls are <br /> load controls and configured to reduce system flow rate by <br /> supply-water 50%,or the maximum allowed by the <br /> temperature reset equipment manufacturer,based upon the <br /> heating or cooling loads;or describe why not <br /> required <br /> C403.4.4 Hydronic system part For hydronic systems with output capacity Z <br /> load controls and 300,000 Btu/h that serve heating water <br /> supply-water systems,chilled water systems and water- <br /> temperature reset cooled unitary air conditioners,indicate that <br /> pumps are provided with a variable speed <br /> drive if one of the following conditions apply: <br /> 1)System pump motor hp is>_2 hp and <br /> pumps are designed to operate continuously or <br /> per time schedule;2)System pump motor hp <br /> is>_7.5 hp and pumps are controlled by <br /> automatic DDC configured to only operate <br /> pumps when there is a call for zone heating or <br /> cooling <br /> C403.4.4 Hydronic system part Where variable speed drives are required, <br /> load controls and indicate system is configured so that pump <br /> supply-water motor power is<30%of design wattage at <br /> temperature reset 50%of design flow rate;indicate pump flow <br /> is controlled to maintain one control valve <br /> nearly wide open,or to maintain a minimum <br /> differential pressure;or exception applied <br /> Page 21132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.