Laserfiche WebLink
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.4.3 Large capacity boiler For boiler system(single or multiple)with> <br /> C403.3.4.4 systems 1,000,000 Btu/h input capacity,indicate <br /> turndown ratio per Table C403.3.4.4 and <br /> method(multiple single input boilers, <br /> modulating boilers,or combination) <br /> NA C403.3.4.1 Large capacity boiler For all boiler systems with input capacity>_ <br /> systems 2,500,000 Btu/h and all systems where one <br /> stack serves 2 or more boilers with a <br /> combined input capacity>_2,500,000 Btu/h, <br /> indicate combustion air positive shut-off is <br /> provided to restrict airflow through the <br /> combustion chamber during standby(e.g.flue <br /> or vent damper). <br /> NA C403.3.4.2 Large capacity boiler For boiler systems with combustion air fans> <br /> systems 10 hp,indicate variable speed fan <br /> NA C403.3.4.3 Large capacity boiler For boiler systems with input capacity>_ <br /> systems 5,000,000 and a steady state full-load <br /> combustion efficiency<90 percent,indicate <br /> combustion air volume to be automatically <br /> controlled to limit stack-gas oxygen <br /> concentrations specified in Table C403.3.4.3. <br /> List exception if it applies. <br /> NA C403.3.4.5 High capacity space For gas hot water space heating systems with <br /> C403.3.4.5.1 heating gas boiler >_ 1,000,000 Btu/h and< 10,000,000 Btu/h <br /> C403.3.4.5.2 system(new capacity,indicate boiler thermal efficiency>_ <br /> buildings) 90 percent;coils and heat exchangers sized at <br /> design conditions to have a boiler return water <br /> temperature<_ 120°F;values and controls to <br /> ensure under all operating conditions the <br /> water temperature entering the boiler is<_ <br /> 120°F or the supply water recirculating <br /> directly into the return system is<20 percent <br /> of design flow of the operating boilers. <br /> C403.2.4 Variable flow For pump motors>_5 hp,indicate method of <br /> capacity-pumps variable flow control(VSD or equivalent <br /> method)in equipment schedule,or exception <br /> applied <br /> NA C403.3.7 Hydronic system flow Indicate chilled water and condenser water <br /> rate flow types and operating hours,and maximum <br /> flow rates in less than or equal to Table <br /> C403.3.7. <br /> NA C403.3.8.1 Chilled-water coil Indicate chilled-water coils sized to provide a <br /> selection 15°F difference between leaving and entering <br /> water temperature and a minimum 57°F <br /> leaving water temperature at design <br /> conditions.,or exception applied <br /> NA C403.3.8.2 Hot-water coil Indicate hot-water coils sized to provide a <br /> selection 20°F difference between leaving and entering <br /> water temperature and a maximum 118°F <br /> entering water temperature at design <br /> conditions.,or exception applied <br /> Page 20132 <br />